- Rating
- 5
- Clarity
- 3
- Confidence
- 5
- Originality
- 4
- Quality
- 3
- Significance
- 3
Read review
Summary
In this paper, the authors propose a two-stage framework for Medical Image Translation. The authors state that current work is limited by its reliance on paired datasets and its tendency to entangle structural preservation with appearance generation, which often distorts underlying clinical anatomy. To overcome these limitations, the framework explicitly decouples these objectives by first constructing a shared structural latent space via an encoder-decoder. It also utilizes a Structural Memory Bank to provide soft structural supervision for source images lacking annotations. In the second stage, a conditional flow model is trained to synthesize Medical Images using the frozen structural representations from the first stage as fixed guidance. They evaluate their method on the OCTA-500 and SynthRAD2023 datasets for OCT-to-OCTA and MR-to-CT translation tasks and showcase superior performance compared to both paired and unpaired baselines.
Strengths and weaknesses
-
This framework guides the Medical Image translation process with soft structural supervision, which helps prevent the distortion of clinical anatomy
-
With the introduction of the Structural Memory Bank, the authors provide a solution to the need for paired datasets and the need for source domain masks
-
Great Quantitative results. The method outperforms both unpaired and paired baselines across both tasks
-
The evaluation relies on controlled, curated datasets: OCTA-500 and SynthRAD2023. Both of these datasets provide controlled environments and fail to fully reflect the complex domain shifts present in the real world where we have diffent scanners and acquisition protocols
-
There is no clear downstream task evaluation to fully demonstrate the clinical utility of the method. While we get superior quantitative results and really niche qualitative result examples, we are still not sure how this method helps in diagnosis.
Questions
How robust is the shared structure of the latent space when subjected to severe out-of-distribution shifts, such as multi-institutional data? What is the impact of this framework on a downstream evaluation task?
Limitations
The framework was evaluated on relatively controlled datasets. While the cases were split into non-overlapping sets, this setup does not fully capture the complex, real-world variations encountered across different institutions, scanners, or patient populations.
The framework's central claim of preserving "clinically meaningful" anatomy is supported only by pixel-level fidelity metrics. No downstream or clinical validation is provided, so the clinical utility of the translation is not fully demonstrated.
Paper formatting concerns
n/a
Final justification
I am pleased with the author responses
Response to Reviewer Xoww
Thank you for recognizing the structural-preservation motivation and strong quantitative results, and for the constructive questions. W, Q, and L denote the numbered Weakness, Question, and Limitation items in your review, respectively.
Issue X1. Generalization under real-world and multi-institutional domain shifts (W1, Q1, L1)
Response:
We thank the reviewer for highlighting generalization under institutional domain shifts. We add a center-held-out evaluation on SynthRAD2023. All evaluated methods are retrained using only data from centers A and B (UMC Utrecht and UMC Groningen) and tested without adaptation on the unseen center C (Radboudumc). No image, annotation, or memory-bank prototype from center C is used during training or model selection.
As shown in Table 9, our method achieves the best performance across all whole-image, soft-tissue, and bone-region metrics, outperforming both unpaired SynDiff and paired DDBM. The gains are particularly pronounced in the bone region, where PSNR/SSIM improves from 14.10/67.49 for DDBM to 17.14/80.45.
These results provide direct evidence of robustness under an unseen institutional shift. Nevertheless, one held-out center cannot cover all scanner, protocol, vendor, or population variations, and broader multi-institutional validation remains necessary.
Table 9. Center-held-out evaluation on the SynthRAD2023 brain MR-to-CT task. All methods are retrained using centers A and B only and evaluated without adaptation on the unseen center C. Results are patient-level means. W, S, and B denote whole image, soft tissue, and bone, respectively.
Issue X2. Downstream diagnostic value and clinically meaningful anatomy (W2, Q2, L2)
Response:
We thank the reviewer for requesting downstream validation. We train a normal-versus-abnormal classifier exclusively on acquired OCTA images from the 450-case training partition and apply it, without adaptation, to acquired and translated OCTA images from the same 50 held-out cases.
As shown in Table 10, our method achieves the highest balanced accuracy among the translated images and most closely preserves the classifier behavior on acquired OCTA, with the lowest probability deviation and decision-flip rate and the highest probability correlation. Its probability deviation is also significantly lower than those of all reported baselines after Holm correction.
These results provide independent downstream evidence that our method better preserves patient-specific disease-discriminative information beyond pixel-level fidelity. Complementary independent vessel evaluation and blinded reader assessment are reported in Reviewer 6DVC, Issue D2. However, this algorithmic evaluation does not establish clinical diagnostic equivalence or improved human decision-making; external validation and expert assessment remain necessary.
Table 10. Independent downstream normal-versus-abnormal classification on the fixed 50-case OCTA-500 test set. The classifier is trained exclusively on acquired OCTA images from the 450-case training partition and is frozen for all evaluations. AUROC and balanced accuracy are evaluated against the disease labels. The remaining metrics measure agreement with the classifier outputs obtained on acquired OCTA. ∣Δp∣ denotes the absolute difference between classifier probabilities on translated and acquired OCTA; Spearman ρ measures their rank correlation; and flip rate denotes the proportion of cases whose binary prediction changes relative to acquired OCTA. The 95% confidence intervals for AUROC and balanced accuracy are computed using case-level bootstrap. The final column reports Holm-adjusted paired Wilcoxon tests comparing ∣Δp∣ for each baseline against our method.
(a) Classification performance
(b) Agreement with acquired OCTA