- Rating
- 4
- Clarity
- 3
- Confidence
- 3
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper presents a compositional latent diffusion framework for 3D brain MRI generation. Unlike conventional generative models that synthesize brain volumes as a single entity, the proposed method decomposes the generation process into anatomical parts and employs a part-to-whole latent refinement strategy to combine independently generated regions into a coherent whole-brain image. The primary goal is to improve local controllability while maintaining global anatomical consistency. Experimental results demonstrate the ability of the proposed approach to generate anatomically plausible brain MRIs while enabling region-level control over the synthesis process.
Strengths and weaknesses
This work presents an anatomically compositional latent diffusion framework for controllable 3D brain MRI generation. The part-to-whole latent refinement approach is interesting and I think it distinguishes it from monolithic models by enabling independent manipulation of brain structures. I believe that this has great potential for simulating specific pathologies and, in general, generating synthetic cohorts. The quantitative results seem convincing to me and suggest that the proposed framework is effective.
However, as the authors have pointed out, their proposed framework introduces higher training and inference costs. It is unclear to me if the current quality gains fully justify this added complexity. My main concerns are related specifically to this “localized anatomical failures, such as blurred tissue interfaces, topological inconsistencies in the cortex, and unnatural asymmetries” (excerpt from the paper) and what I mean by this being a concern is that the paper only shows whole-brain images and quantitative results on whole-brain as well. I want to see more evidence that the proposed model is better at tissue interfaces (quantify the blurriness or sharpness in these regions) or show how the baselines produce topological inconsistencies.
Questions
In the introduction you say “Whole-brain samples that appear realistic at a macroscopic scale can exhibit localized anatomical failures, such as blurred tissue interfaces, topological inconsistencies in the cortex, and unnatural asymmetries. These localized artifacts compromise the downstream utility of the generated data, as shown in Fig. 1.” -- Can you please use arrows and point to these issues “blurred tissue interfaces, topological inconsistencies in the cortex, and unnatural asymmetries”?
Also, the pie radar chart from Figure 1 - can you please reference it in the text somewhere? I am not sure I understand what the message behind it is? I am a bit confused by this figure because I thought for both Cohen’s and FID the smaller the better, and so I would assume the “ours” lines should be closest to the centre instead of furthest apart? In any case, the figure does not really have labels.
Can you please be consistent between tables? Bold vs. underlined as shown in Table 2 is probably the way to go for Table 1 as well for consistency but also because red vs. yellow won’t show well if any readers decide to print the paper in black and white.
Why only ventricles / cerebellum / brainstem? Are the other labels produced by SynthSeg not giving good results?
Figure 3 - You say “Existing models that synthesize 3D volumes monolithically often overlook fine-scale anatomical structures or suffer from localized artifacts.” - Please add some arrows or zoomed in regions in the images as I cannot seem to visually find the localized artifacts or what fine-scale structures are overlooked.
Can you please define some of the abbreviations used? For example, at line 231 you say “FIDs are computed…” but I cannot find the non-abbreviated version of FID. If you mean “Fréchet Inception Distance” then I don’t see it spelled out anywhere. Some other abbreviations are missing as well.
Minor comment: Why comic sans?
Limitations
Yes, the authors have discussed limitations of their work and I would add that at the moment the results are for whole-brain and I would like to see more results on localised anatomical features.
Paper formatting concerns
N/A
Final justification
The authors have addressed and clarified the concerns I raised. Having considered the discussion, I have increased my rating to Borderline Accept.
Scope of baseline comparisons. We thank the reviewer for identifying this missing comparison. We agree that the scope of current experiments is limited. We are adding ControlNet LDM, grid-based LDM, VAE-GAN, and HA-GAN baselines. Previously, we included the whole-brain LDM and segmentation-conditioned LDM baselines because they use closely matched latent representations and denoising backbones as AnaDiffusion, allowing the comparison to more directly study anatomical compositionality within a controlled latent-diffusion setting. MorphLDM additionally provides a morphology-driven generative comparison, although it remains within the broader latent-diffusion family.
Table R1. Comparison to additional baselines: ControlNet LDM and Grid-based LDM. MedicalNet FID is reported as FID × 10⁴. Lower is better.
Grid-based LDM applies positional encoding to each of the 3x3x3 patches (27 total), designed to separate anatomical semantics from spatial specialization.
In Table R1, we performed 5,000 nonparametric cluster-bootstrap replicates on the held-out cohort of 291 scans from 61 subjects: in each replicate, we sampled 61 subjects with replacement and retained all longitudinal scans belonging to each selected subject, while independently resampling 291 generated volumes with replacement for each method. We then recomputed MedicalNet FID. We report bootstrap means with 95% percentile confidence intervals.
SynthSeg independence. We thank the reviewer for raising this important concern and appreciate the opportunity to clarify the data flow. AnaDiffusion uses a subject-disjoint ADNI split, and no held-out test scan or SynthSeg output generated from a test scan is used to train the autoencoders, regional diffusion models, or whole-brain diffusion model. For data preparation, SynthSeg is applied to preprocess the ADNI images to extract part volumes and MNI 152 template to define the regional crops. During both training and inference, AnaDiffusion does not require any subject-specific SynthSeg map; fixed MNI152-derived regional masks localize the part latents, and the generated regional assets provide the masks used for reinjection. For evaluation, we followed prior brain-generation studies, including Wu et al. [1], in using SynthSeg quality control and regional-volume effect sizes across all compared generators. However, because the SynthSeg training subject identifiers are not publicly available for exact matching, we cannot guarantee that none of our held-out ADNI subjects contributed anatomical labels to the SynthSeg prior. We will state this information explicitly in the SynthSeg-based results.
Asymmetric hemisphere ablation. We thank the reviewer for noting that the hemisphere-specific results require a more thoughtful interpretation. Separate hemisphere models improve left-hemisphere FID from 5.68 to 4.97 but worsen right-hemisphere FID from 6.17 to 8.35. Therefore, this ablation does not demonstrate that weight sharing uniformly improves every hemisphere-specific metric. At the whole-volume level, however, the shared hemisphere model improves whole-brain FID from 36.40 to 34.33 and reduces the mean bilateral FID from 6.66 to 5.93, indicating better average bilateral balance and downstream whole-brain composition despite the side-specific trade-off. We interpret this pattern as a possible sample-efficiency and regularization trade-off. Canonicalizing the right hemisphere into the left-oriented coordinate system allows the shared model to pool observations from both sides when learning homologous cortical and subcortical structure, while the side-conditioning embedding preserves laterality information. Separate models provide greater side-specific capacity but each receives fewer effective training examples and may therefore exhibit greater optimization, sampling, or finite-sample FID variability. More broadly, recent work has shown that representational ordering can produce direction-dependent performance differences in vision models: REOrder reports substantial changes under alternative patch permutations [2], and Flatten Wisely reports statistically significant scan-order effects across MRI segmentation datasets [3]. These sequence-model studies do not directly explain our convolutional U-Net results, but they reinforce that asymmetric performance should not be attributed to biological laterality without targeted experiments. We will revise the discussion to present these explanations as hypotheses. We are particularly interested in this asymmetry and would welcome the opportunity to investigate these effects more.
Clarification of claims about ADNI. We agree that phrases such as “improves ADNI” are imprecise because ADNI is the training and evaluation dataset rather than an object being improved. We will revise these statements to specify that AnaDiffusion improves the evaluated synthesis metrics on held-out ADNI subjects relative to the compared baselines. We will also consistently state that the model was trained on the ADNI training split and evaluated on a subject-disjoint ADNI test split.
Downstream utility. We agree that distributional and morphometric metrics alone provide limited evidence of practical utility. AnaDiffusion’s modular design allows region-specific conditioning, offering a mechanism to model heterogeneous anatomical or disease-related variation across brain components. We also added a structural agreement analysis between generated and real test volumes. AnaDiffusion shows stronger volumetric and boundary agreement than the LDM baseline, suggesting that its samples may be suitable as synthetic training data for segmentation models [4]. Confirming this utility will require a dedicated synthetic-to-real downstream segmentation experiment.
Table R2. Structural agreement between generated and real test volumes using SynthSeg-derived anatomical labels. Dice (↑) measures volumetric overlap, while HD95 (↓) measures the symmetric 95th-percentile Hausdorff surface distance in millimetres [4]. Compared with LDM, AnaDiffusion achieves higher Dice in 16 of 17 regions and lower HD95 in 16 of 17 regions, indicating improved anatomical consistency.
References:
[1] Wu et al., “Evaluating the Quality of Brain MRI Generators,” MICCAI, 2024.
[2] Kutscher et al., “REOrdering Patches Improves Vision Models,” 2025.
[3] Hardan et al., “Flatten Wisely: How Patch Order Shapes Mamba-Powered Vision for MRI Segmentation,” 2025.
[4] Taha and Hanbury, “Metrics for evaluating 3D medical image segmentation: analysis, selection, and tool,” 2015.
[5] Chang et al., “Mining multi-center heterogeneous medical data with distributed synthetic learning,” 2023.