- Rating
- 4
- Clarity
- 2
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper introduces a Semantics and Structure Loss for mask-guided CT generation. The SID loss aligns HU distributions for different organs and tissue-specific regions, while the SA loss regularizes anatomical structure using gradient-based constraints. The effectiveness of this loss is evaluated across different backbones. Specifically, the method is tested on SegRap and AutoPET using GAN, diffusion, flow, and 3D foundation-model backbones. On downstream segmentation task, the generated image can train models that outperform models trained on real data.
Strengths and weaknesses
Strengths:
-
The proposed loss is intuitive and well motivated. The SID loss targets tissue-specific HU distribution alignment, while the SA loss targets structural fidelity through anatomical gradients.
-
The paper also evaluates the loss across different generative backbones, including GAN, diffusion, flow, and a 3D foundation model, and the comparison is quite comprehensive, benchmarking the paper against rich competitors.
Weaknesses
-
My major concern is that the proposed loss may reduce conditional diversity. Mask-guided CT synthesis is naturally a one-to-many problem: the same mask can correspond to multiple plausible CT images. However, the proposed loss is computed between the generated CT and the corresponding real CT during training. This may push the model toward one specific target image for each input mask. This does not necessarily mean that the model will always generate the same image for a given condition, but the paper does not evaluate whether multi-sample diversity is preserved. The authors should show multiple generated samples from the same mask and analyze whether LS2 reduces variation.
-
The application of these image space loss functions are also limited. The paper claims that LS2 works with diffusion and flow models, but the integration details need more clarification. First, the flow formulation seems tied to a simple linear path or per-step clean-image estimate. Second, for latent space generative models, the author doesn't explain how the loss function interacts with the VAE. Third, in diffusion steps, the author estimated a clean image every step, which, at early stage of diffusion, can be really unreliable. Last, and least, the reviewer think the integration details should be put in the main text, not just in the appendix.
-
Another weakness is readability, especially in Section 3.3 and the experiment section. Section 3.3 gives a frequency-domain explanation for why semantic-structure modeling may improve spectral alignment. This is useful intuition, but it does not establish causality in the usual sense. There is no causal intervention or causal identification. The paper should probably call this a frequency-domain interpretation rather than a causal perspective.
The experiment section also misses some important details in the main text. For example, Table 2 shows that training with LDM-generated data gives better downstream segmentation performance than training with true data, and LDM+LS2 improves further. This is possible, but counterintuitive. The authors should clarify the exact downstream setup: whether the amount of training data is equal, whether synthetic and real data use the same masks, whether the test set is fully real and disjoint, and whether there is any risk of mask-to-image leakage.
Justification of my ratings below:
Quality: 2 Not good. The method is reasonable, but several important experimental details are missing or unclear.
Clarity: 2 Not good. The high-level idea is understandable, but Section 3.3 is hard to follow and uses “causal” too strongly. The experiment section also omits key setup details that are needed to interpret the results.
Significance: 2 Not good The problem is important, but the loss functions provided is limited to specific settings of flow matching and diffusion.
Originality: 3 Good. The paper does not propose a new generative model, but the CT-specific loss design is useful and reasonably original. The main contribution is the semantic intensity distribution loss and structural anatomy loss, and their application across different model families.
Questions
- Since LS2 compares the generated CT with the corresponding real CT, does it push the model toward a single target image for each mask? Some diversity or stochasticity analysis would be helpful.
- For latent diffusion models, is LS2 computed after VAE decoding? Since SID and SA depend on HU values and image gradients, computing them in latent space would be hard to interpret.
- Is the VAE frozen when applying LS2 to LDM? If the VAE is imperfect at reconstructing HU values, SID may penalize the diffusion model for VAE reconstruction errors.
- Section 3.3 is useful as a frequency-domain interpretation, but the term “causal” seems too strong. There is no actual causal intervention or causal identification.
- In Table 2, why does training on LDM-generated data outperform training on true data? This is possible, but counterintuitive and needs a clearer explanation. And details for these experiments are also essential. For example, are the real-data, LDM-data, and LDM+LS2-data training sets the same size? Additionally, the Dice and IoU values in Table 2 do not appear to follow the usual Dice-IoU relationship. This may be valid if different averaging schemes are used, but the paper should define this clearly.
- [Nit] How sensitive is SID to the choice of HU windows and organ masks?
Limitations
No. The paper does not include a dedicated limitations section. Several important limitations are not well discussed. For example, the computational cost of reconstructing a clean image estimate during diffusion or flow training, the interaction with latent diffusion/VAE decoding, and the practical application scenarios (latent diffusion, pixel-space diffusion) are not clearly addressed. The authors should discuss these limitations more explicitly.
Paper formatting concerns
No
Final justification
After considering the rebuttal and subsequent discussion, I have raised my score to 4.
I consider the work technically solid, although the presentation of the paper should be better enhanced to make sure on reproducibility.
Weakness1 and question1: multi-sample diversity under LS2
We will add diversity analysis in the revision.
On AutoPET test set, we sampled 10 times per mask across head, chest, and abdomen using LDM and LDM+LS2, and computed LPIPS (perceptual diversity), (1−SSIM) (structural diversity), and HU-W1 (HU distribution diversity). LDM+LS2 reduced LPIPS from 0.0506±0.0195 to 0.0353±0.0148 and (1−SSIM) from 0.1314±0.0436 to 0.0948±0.0284. This is consistent with design of LS2 since it would reduce unstable visual and structural variations.
However, diversity does not collapse. HU-W1 only decreased from 1.8949±0.5328 to 1.7671±0.3670, indicating intensity variations from random sampling are largely preserved. Visualizations confirm that unconstrained regions (e.g., muscle, soft tissue, boundary details) still vary reasonably. Since links for images are nor permitted here, figures will be in the revision.
Overall, LS2 constrains organ-level distributions, not pixel-wise reconstruction, so it does not collapse one-to-many to one-to-one. The experiments confirm LS2 filters unanatomical variations while preserving stochasticity, achieving a favorable fidelity–diversity trade-off.
Weakness2 and question2,3: integration details
Thank you for the detailed suggestions. We will add the integration details to the main text.
For LDM, LS2 is computed in image space. The VAE decoder is frozen; it decodes the latent code into an image, where LS2 is computed, and gradients pass through the decoder to the diffusion. VAE reconstruction is accurate (AutoPET: MAE 0.0039, SSIM 0.9824, PSNR 36.97; SegRap: 0.0028, 0.9893, 38.52). Although frozen VAE errors remain, the same VAE is used for baseline and LS2 and comparisons are fair. We will explicitly state that VAE reconstruction fidelity sets an upper bound for LS2 performance under LDM framework. In order to keep LS2 definition consistency and comparison fairness across all baselines, we do not apply time-step weighting to diffusion training. Despite this, LS2 still improves results obvisouly (Table 1). We leave it as future work.
For flow, LS2 applies the same way: any flow that outputs a differentiable clean-image prediction can compute SID and SA in image space. Equation (12) is specific to our MOTFM flow setup and is not a requirement for LS2. LS2 only needs an image-space prediction, regardless of the flow path. We will clarify this in the main text.
Weakness3 and question4: frequency-domain interpretation
We agree that "causal perspective" is inappropriate and will revise it. We will also add data analysis and spectral validation of frequency improvement to better support our claims in the revised manuscript.
Intuitively, compared with arbitrary image patches, patches within anatomical masks exhibit more concentrated HU distributions and lower spatial intensity variation in CT. In AutoPET, organ-mask patches show substantially lower intensity variation (std: 48.53 vs. 157.15; IQR: 46.09 vs. 159.50; median absolute deviation: 20.35 vs. 37.42) and smaller gradient magnitudes (mean gradient: 12.68 vs. 22.31; total variation: 24.87 vs. 35.97) compared to random patches. This provides empirical support for the link between organ-level distribution constraints and low-frequency consistency.
We clarify that our claim is not that SID theoretically guarantees low-frequency alignment for all images. Rather, the observed spectral improvements are an empirical byproduct of semantic-structural regularization on medical CT data, where organ-level intensity distributions are inherently constrained.
As for additional spectral validation, we compared SID with the differentiable histogram loss in [1] (suggested by reviewer 4Kg1), applied either globally or within organ masks under the same pix2pixHD settings in Table 1 of paper. The baseline low-frequency error (LF error) was 0.491±0.061. The global histogram loss reduced it to 0.480±0.062, whereas the organ-wise histogram loss further reduced it to 0.451±0.058. The high-frequency error (HF error) remained almost unchanged for the organ-wise histogram loss (0.416±0.042 vs. 0.418±0.043 for the baseline), while HU-W1 improved from 188.706±4.960 to 167.553±15.672.
Notably, SID produced a larger improvement compared to [1], reducing HU-W1 to 162.303±21.320 and LF error to 0.391±0.051, a reduction of approximately 20.4% from the baseline. Its HF error remained close to the baseline at 0.408±0.037, indicating that its main effect is organ-aware HU alignment accompanied by improved low-frequency spectral consistency, rather than uniform improvement across all frequency bands. In contrast, SA had little effect on the LF error but reduced the HF error to 0.295±0.013. Combining SID and SA, LS2 achieved LF and HF errors of 0.389±0.047 and 0.287±0.022, respectively, together with the best SSIM of 0.752±0.048 and the lowest HU-W1 of 159.242±4.668.
\hline Method & SSIM & HU-W1 & LF\\ error & HF\\ error \\\\ \hline pix2pixHD & 0.719±0.057 & 188.706±4.960 & 0.491±0.061 & 0.418±0.043 \\\\ [1]-organ & 0.710±0.053 & 167.553±15.672 & 0.451±0.058 & 0.416±0.042 \\\\ [1]-global & 0.714±0.055 & 170.190±14.672 & 0.480±0.062 & 0.418±0.033 \\\\ SID & 0.736±0.051 & 162.303±21.320 & 0.391±0.051 & 0.408±0.037 \\\\ SA & 0.743±0.052 & 171.552±4.596 & 0.482±0.060 & 0.295±0.013 \\\\ LS2 & 0.752±0.048 & 159.242±4.668 & 0.389±0.047 & 0.287±0.022 \\\\ \hline \end{array}$$ [1] M. Avi-Aharon, A. Arbelle, and T. Riklin Raviv, “Differentiable Histogram Loss Functions for Intensity-Based Image-to-Image Translation,” IEEE Transactions on Pattern Analysis and Machine Intelligence, vol. 45, no. 10, pp. 11642–11653, Oct. 2023, doi: 10.1109/TPAMI.2023.3278287. **Question5: downstream segmentation protocol and interpretation** We will add full segmentation details in the revision. Segmentation experiments used the same patient-wise split as synthesis (90/20/10 for train/val/test on SegRap), with no patient overlap. All segmentation models were trained and validated solely on synthetic CTs paired with real masks. The same patients, masks, and sample sizes were used across all segmentation experiments. Evaluation was conducted exclusively on real CTs and real masks from unseen test patients—no leakage occurred. We acknowledge that using the same mask as generation condition and segmentation label increases image-label consistency, but this is not test-set leakage. Why synthetic-only outperformed real-only: (1) Synthetic CTs are more standardized, with less scanner noise, acting as regularization. (2) Real CTs and manual annotations may have boundary misalignment, while synthetic CTs provide more label-consistent training pairs. Importantly, we do not claim that synthetic data are superior to real data. LDM data generated with LS2 achieved better performance on the independent real test set, indicating improved synthetic-to-real transfer utility. Nevertheless, the experiment was conducted on only 10 test patients from the single-center SegRap dataset. The result should therefore be interpreted cautiously and larger multi-center studies are required for synthetic and real comparison. As for Dice–IoU relationship, our averaging scheme is: Dice and IoU were first computed independently for each organ on each 2D slice. The slice-level values were then macro-averaged (weighted equally regardless of region size) within each organ, followed by macro-averaging across organs to obtain the reported mean Dice and mean IoU. The nonlinear Dice–IoU conversion ($IoU_i = Dice_i/2-Dice_i$) holds per sample, but not after macro-averaging: $$\frac{1}{N}\sum_{i=1}^{N} IoU_i \neq \frac{ \frac{1}{N}\sum_{i=1}^{N} Dice_i }{ 2-\frac{1}{N}\sum_{i=1}^{N} Dice_i }$$For example, consider two slices with Dice of 1.0 and 0.1. Their mean Dice is 0.55. The corresponding IoU are 1.0 and 0.0526, giving a mean IoU of 0.5263. In contrast, converting the mean Dice directly via IoU-Dice relationship would yield 0.55/(2−0.55)=0.3793. **Question6: sensitivity of SID to HU windows and organ masks** Thank you for this question. We will add the following clarifications in the revised manuscript. HU windows. All experiments use a unified preprocessing where CT is clipped to [−1000, 1000] HU. This is a standard practice to remove air and noise. SID internally applies multiple HU windows that provide non-exclusive but full coverage of [−1000, 1000] HU, allowing the focus on different tissue intervals. The same window setting is used for both AutoPET and SegRap without dataset-specific tuning. For normal anatomical CT, fixed windows are sufficient; for disease-specific tasks (e.g., lung lesions), window weights could be adjusted, which we leave for future work. Organ masks. SID does not rely on a fixed organ sets. It computes distribution constraints only for annotated organs and averages across valid organs, preventing small structures from being dominated by large ones. Thus, although AutoPET and SegRap have different organ sets, SID could apply directly without redesign. Notably, different HU window and organ choices may affect the improvement. This depends on dataset quality and anatomical characteristics. Our unified settings already yield consistent gains across different baselines; further tuning or task-adaptive weighting could be explored in future work. **Response to limitation** We will discuss limitations more comorehensively. First, LS2 adds training-time and memory overhead during diffusion/flow training due to clean-image reconstruction and image-space loss computation, but incurs no extra inference cost. Second, LDM performance is bounded by frozen VAE reconstruction fidelity. Third, diffusion models have high inference latency. For time-critical applications like online adaptive radiotherapy, faster LS2-constrained frameworks are needed. Clinical deployment also requires real-time workflow validation, dosimetric assessment, and safety analysis.