- Rating
- 3
- Clarity
- 2
- Confidence
- 4
- Originality
- 3
- Quality
- 2
- Significance
- 2
Read review
Summary
This paper addresses 3D medical image synthesis, motivated by the trade-off that fully volumetric generators are expensive while purely slice-wise 2D generators struggle to maintain consistency along the through-plane axis.
The central idea is a factorization: a predominantly 2D synthesizer handles high-resolution in-plane slice formation, while a lightweight, depth-indexed "trajectory" module handles only through-plane organization.
The method is evaluated across three settings—unconditional MR generation (BraTS 2023), missing-modality MR synthesis (BraTS 2023, vs. cWDM), and MR-to-CT synthesis (SynthRAD2023)—reporting per-slice quality, through-plane coherence, inference cost, a no-mapper ablation, and appendix analyses (bootstrap CIs, paired Wilcoxon tests, a memorization probe, and depth-trajectory PCA).
I read the main contributions as: (1) the 2D-synthesizer-plus-lightweight-trajectory-module factorization, with the claim that through-plane organization can be added cheaply; (2) LiFT-U, using a frozen 2D generator and a depth mapper trained by tri-planar drift; (3) LiFT-C, using a BiGRU z-context mixer with memory-efficient native-resolution inference; and (4) an evaluation showing the principle transfers across both unconditional and paired regimes at lower inference cost than volumetric or iterative alternatives.
Strengths and weaknesses
Strengths : The experiment is basically complete. I think the idea is somewhat novel. The evaluation indicators are also basically appropriate.
Weaknesses : 1. The comparisons neither establish SOTA nor isolate the contribution against the right baselines. My main concern is that the experimental design does not cleanly support the central claim. Two problems compound. First, on the paired tasks the results do not actually demonstrate state-of-the-art performance, and the paper's framing slightly obscures this. On missing-MR (Tables 2–3), LiFT-C trails cWDM on the averages for both PSNR (28.31 vs. 28.42 dB) and SSIM (0.9518 vs. 0.9525), and the authors' own paired Wilcoxon tests find no significant difference at any contrast (p≥0.37). Second, LiFT is benchmarked only against fully-volumetric and naive slice-wise baselines.
2. Figures 1 and 2 are difficult to follow and, in places, internally inconsistent. I am concerned they were AI-generated without careful post-editing. The clearest symptom is in Figure 2, whose legend does not map onto the formulation it is supposed to illustrate. The drift loss in Eq. (4) involves exactly three objects: the generated feature gg g, the bank of real features {rk}, and the kernel-weighted local target μ. The legend, however, lists more marker types than this, and they cannot be matched back to the equation. Most confusingly, it contains two separate entries that both read "local mean"—"Drift target (local mean)" (the × glyph) and "Drift target in real distribution (local mean)" (the ⋆ glyph)—using different markers but identical descriptions. A reader cannot tell whether these denote the same quantity (in which case why two glyphs?) or two different quantities (in which case the labels fail to distinguish them).
3. The architecture of the depth mapper is never specified. The paper describes it only as a "lightweight network" with a M parameter count (Appendix E.1), but gives no layer structure—is it an MLP, and of what depth?—and never states the dimensions of , , or (the symbol is introduced in Eq. (1). For a paper whose central contribution is precisely "a lightweight depth-indexed trajectory module," leaving both the module's architecture and its interface to the generator undefined directly undermines reproducibility.
4. The paper lacks experimental setups and visualizations specifically targeting the inter-slice inconsistency problem. Given that through-plane coherence is the stated core contribution, the evaluation should be built around it directly—dedicated experiments and qualitative reformats that isolate and display slice-to-slice consistency—rather than relying on aggregate quality scores and figures that do not clearly show it.
5. The MR-to-CT no-mapper ablation conflates two mechanisms and so cannot attribute the improvement. Per Appendix E.3, "no mapper" is Stage 1 alone—a plain per-slice 2D U-Net with no BiGRU and hence no depth encoding—while the full model adds, simultaneously, both the BiGRU sequence model (which actually reads neighboring slices) and the Fourier depth signal γ(d). This matters for what the contribution is: if adding a plain normalized scalar depth input to the Stage-1 U-Net (no BiGRU) already recovered most of the benefit, the BiGRU-plus-Fourier design would not be shown to be necessary. I would suggest an intermediate ablation—no mapper → Stage-1 + depth encoding only, no BiGRU → full—to separate the two. Relatedly, the Fourier encoding itself is left unspecified (normalization of ddd, number/scale of frequencies), which is a reproducibility gap; for LiFT-U, where the trajectory module is not removable, this is purely a specification issue rather than an attribution one.
Questions
Please refer to the weaknesses.
Limitations
Overall, I find the motivation of this paper appealing: the inversion of the usual question—asking how little explicit 3D processing is needed once a strong 2D model is in place, rather than how to make a 3D generator cheaper—is a genuinely interesting starting point. My main suggestion is that the writing, the experimental design, and the figures do not yet cohere around this motivation as well as they should, and this is where the paper most needs improvement. Concretely: the evaluation should be built more directly around through-plane coherence (the stated core idea), including a direct coherence metric for LiFT-U and at least one comparison against a competing 2D-lifting method rather than only volumetric and naive slice-wise extremes; the exposition should fully specify the components that carry the contribution (MϕM_\phi Mϕ, the conditioning interface, the context merge) rather than the peripheral details; and the figures need to be redrawn so they accurately and clearly convey the mechanism. With the motivation tightened into the design, evaluation, and presentation in this way, this could become a considerably stronger submission.
Paper formatting concerns
N/A
Final justification
After reading the rebuttal and discussion, I raise my rating from 2 to 3. The authors clarified the architecture, added the requested depth-only ablation, provided stronger statistical analysis of through-plane coherence, and expanded comparisons with recent baselines, which make the quality–efficiency claim more convincing.
Thank you for the detailed, point-by-point review. We appreciate the specific concerns about baseline positioning, presentation, reproducibility, direct coherence evidence, and the MR-to-CT ablation. We address each below and report two new analyses: a direct coherence evaluation and the requested depth-only control.
1. Baselines, SOTA framing, and comparison with 2D-lifting methods. Our intended claim is not that LiFT has the best image-quality metric in every task. The main result is the quality–efficiency trade-off. On missing-MR, LiFT-C is within approximately 0.12 dB PSNR and 0.0007 SSIM of cWDM, while reducing inference time from 156.4 s to 1.16 s per volume (~135×). The nonsignificant paired Wilcoxon result does not establish equivalence or non-inferiority. We are re-evaluating the comparison with a formal equivalence/non-inferiority test and do not interpret the current p-values as evidence of equivalence.
We also completed a matched MAISI-v2 experiment on BraTS T1n at 128³ using the same MedicalNet-FID protocol:
Both timings were measured on an NVIDIA RTX 5090. Matched 3D MedDiffusion and Fast-cWDM evaluations are in progress, and we will share verified results as soon as they are available.
Table 1 includes the 2.5D-LDM result reported by WDM, which is a Make-A-Volume-style adaptation under the same evaluation protocol. However, this is a quoted result rather than our own matched reproduction, so it only partially addresses the requested baseline comparison. We will clarify this limitation and avoid presenting it as an independently rerun comparison.
2. Figures and presentation. We apologize that the current figures mix the shared conceptual idea with task-specific implementations, making the relationship between LiFT-U and LiFT-C harder to follow. We are revising the presentation by separating the conceptual overview from the two implementation diagrams, simplifying the notation, and making the captions self-contained.
The two Figure 2 legend entries labeled “local mean” are an editing error, not two different quantities. Both refer to the same kernel-weighted local target μ in Eq. (4). The revised figure will use a single marker for μ and show only the three quantities used by the loss: the generated feature g, the real feature bank {r_k}, and the local target μ. We will also label Figure 1 explicitly as a conceptual overview rather than a literal architecture diagram. We appreciate your careful attention to these presentation errors.
3. Depth mapper, conditioning interface, and reproducibility. We agree that these details are necessary for reproducibility and should have been stated explicitly. For LiFT-U, z∈R^{256} is combined with a Fourier encoding of depth and mapped to c_d∈R^{512} by a four-layer SiLU MLP followed by a lightweight residual depth refiner. The mapper has ≈1.455M trainable parameters, and each c_d conditions the frozen 2D generator through adaptive GroupNorm at every residual block. We will add the exact layer widths, Fourier-feature setup, kernel sizes, and initialization details in the revision. For LiFT-C, recurrence is applied only at the bottleneck and merged through a zero-initialized residual 1×1 convolution. The missing-MR model uses a two-layer bidirectional GRU over pooled 512-D slice descriptors, while the MR-to-CT model uses a single-layer bidirectional GRU over a 256-channel 16×16 bottleneck feature map. In item 5, the two BiGRU cells use the same MR-to-CT architecture and differ only in whether the depth term is included.
4. Direct evaluation of through-plane coherence. We appreciate this request and added direct through-plane measurements rather than relying mainly on aggregate image-quality metrics.
For LiFT-C, we evaluated the full model and the no-mapper control on the same 219-subject missing-MR validation set:
The full per-contrast results improve all 12 cells (four contrasts × three metrics); the table reports the cross-contrast averages and the largest contrast-specific change.
For LiFT-U, paired derivative error is not defined because generated samples have no paired targets. We therefore added a real-calibrated roughness measure, A=Rz/Rxy, where Rz is adjacent-slice roughness and Rxy is in-plane roughness:
This control shows that LiFT-U is far more orderly than a random slice permutation and that its through-plane roughness is on a similar scale to real BraTS volumes. It does not establish anatomical equivalence.
We are also revising the qualitative presentation so that coronal and sagittal reformats, rather than only axial slices, are used to make through-plane behavior easier to inspect.
5. MR-to-CT depth-only ablation. The submitted no-mapper ablation removed both recurrent context and depth encoding, so it could not isolate which component produced the gain. We therefore ran the intermediate control requested in the review.
The new control results are:
Depth conditioning gives no improvement—it is essentially unchanged with or without the BiGRU—whereas recurrent context improves MAE by approximately 1.1 HU. This indicates that the gain is associated with inter-slice context rather than absolute slice position. We appreciate this suggestion, as the requested control helped us identify and isolate this important finding.
The individual ingredients—2D generators, GRUs, and Fourier features—are established. The contribution is the specific separation of responsibilities: the 2D model retains the high-capacity spatial synthesis path, while the added module is restricted to through-plane interaction. The new ablation and direct coherence measurements now test that separation much more directly than the original submission did.
We appreciate the specificity of these comments; the added controls, coherence analysis, and clearer technical description make the central claim substantially easier to assess.