- Rating
- 4
- Clarity
- 2
- Confidence
- 4
- Originality
- 3
- Quality
- 2
- Significance
- 2
Read review
Summary
SliceWorld treats an axial CT study as an ordered slice sequence and learns a factor-aware latent state consisting of anatomy, lesion, and uncertainty components from prefix evidence. These states are projected into world tokens as context for LLM decoding. The model is pretrained with multi-step future-slice prediction, factor-aware learning, and lesion-factor counterfactual objectives, then fine-tuned on paired CT-report data. Experiments on M3D-Cap and CT-RATE report improvements over CT and medical VLM baselines, with additional analyses on future-slice prediction, factor alignment, lesion intervention, reduced-slice robustness, and expert-rated quality.
Strengths and weaknesses
The paper tackles an important use-inspired problem: CT report generation needs aggregation of volumetric, slice-ordered evidence rather than a single-image or global-volume-to-text mapping. SliceWorld is conceptually appealing in converting axial evidence into a predictive, partially intervenable latent state before generation—a more structured formulation than direct image-to-text.
Strengths: The motivation is clear and clinically meaningful, as modeling axial continuity is a reasonable inductive bias. The method is complete (slice encoder, causal sequence encoder, factor-aware states, world-token projection, LLM decoding, multi-objective pretraining). The evaluation is unusually broad—beyond NLG metrics, it includes clinically oriented metrics, ablations, future-slice prediction, factor-alignment probes, lesion intervention, reduced-slice robustness, and expert ratings. The Direct CTRG → +Recon → +MFP → +FAS → Full ablation gives useful evidence that predictive and factor-aware/counterfactual pretraining help.
Concerns: (1) The "world model" claim is only partially supported: prediction is in DINOv2 feature space, not over HU-valued slices, anatomy, masks, or clinical state transitions, so it remains unclear whether SliceWorld learns a structured world state or merely benefits from predictive pretraining of a causal encoder; the persistence/linear-extrapolation baselines are too weak to settle this. (2) Relevant recent CT systems—especially anatomy-guided and region-grounded approaches—are absent from the main tables; without explicit justification, the "consistent improvement" claim may be overstated. (3) Factor decomposition and controllability are under-evidenced: all three factors derive from the same hidden state, so the probes show some specialization but not disentanglement, and it is unclear whether lesion-zero changes reports via a meaningful lesion factor or via distribution shift from zeroing part of the latent—lesion-zero is latent report modulation, not a clinically validated counterfactual. The paper is well written and careful not to overclaim physical simulation, but "world model," "controllable," and "counterfactual" should be used more conservatively unless backed by stronger evidence.
Questions
-
Can the authors compare against, or clearly justify the absence of recent CT-specific report-generation systems that use anatomy-guided, graph-based, region-guided, or grounding-based modeling? A stronger answer here could increase my confidence in the significance of the empirical results.
-
Can the authors include stronger predictive-pretraining baselines beyond persistence, linear extrapolation, and reconstruction? For example, a causal masked slice modeling baseline, contrastive predictive coding, a Mamba sequence encoder pretrained only with future-feature prediction but without factor decomposition, or a 3D encoder + LLM prefix baseline would help determine whether the gain comes from the proposed world-state design rather than generic predictive pretraining.
-
How much information leakage exists across the anatomy, lesion, and uncertainty factors? I would like to see cross-factor probes, e.g., lesion prediction from the anatomy factor, z-location prediction from the lesion factor, and prediction-difficulty estimation from the lesion/anatomy factors. If leakage is substantial, the factor-specialization and controllability claims should be weakened.
-
Can the authors test factor swapping or lesion insertion, not only lesion-zero removal? For example, transferring a lesion factor from one study to another while keeping anatomy fixed would be a stronger test of whether the lesion factor carries controllable lesion-specific evidence.
-
Can the authors report stability across random seeds for the main ablation results and, if possible, more detailed expert-evaluation analysis such as error categories, inter-rater disagreement, and finding-level clinical correctness?
Limitations
Partially. The paper does acknowledge several important boundaries, however, and should be stated explicitly: (1) feature-space future prediction is weak evidence for genuine "world modeling," and (2) the same-hidden-state design admits information leakage across the anatomy, lesion, and uncertainty factors, which directly bears on the disentanglement and controllability claims.
Paper formatting concerns
No major formatting or anonymity concerns identified.
Final justification
I am raising my score from Borderline Reject to Borderline Accept.
The rebuttal addresses my main concerns about whether the reported gains arise from the proposed factor-aware world-state design rather than generic predictive pretraining. The authors add matched controls under the same CT-RATE setting, including causal masked-slice modeling, future-feature pretraining without factor decomposition, and a 3D encoder with an LLM prefix. SliceWorld performs best across BLEU-1, GREEN, and RaTEScore, which provides substantially stronger evidence for the contribution of the full predictive, factor-aware, and intervention-sensitive design.
The rebuttal also improves the empirical positioning of the method. The authors provide a directly comparable result against CT-AGRG on the official CT-RATE split and explain why several other recent CT report-generation systems use materially different datasets, splits, metrics, or auxiliary resources. In addition, the cross-factor probes show that each intended factor performs best on its corresponding target, while the nonzero off-diagonal results appropriately reveal residual information sharing. I appreciate that the authors now characterize this behavior as preferential specialization rather than independence or perfect disentanglement.
The added lesion-factor swapping experiment further strengthens the controllability analysis. Across three findings, most swapped reports change toward the donor label in both directions. The three-seed results also show small run-to-run variation, and the additional expert error analysis provides useful context on the remaining clinical mismatches.
Some concerns remain. The term “world model” should still be interpreted in the restricted sense of a predictive latent-state model over ordered CT features, rather than a general simulator of anatomical or pathological dynamics. Likewise, lesion-factor intervention supports latent report modulation but does not establish clinically valid causal counterfactuals. The number of directly comparable recent CT-specific baselines also remains limited.
Overall, the rebuttal resolves or substantially reduces my main technical concerns. The remaining issues primarily concern terminology, claim scope, and clinical interpretation rather than a fundamental flaw in the method or evaluation. I therefore raise my recommendation to Borderline Accept.
We thank the reviewer for the detailed questions on evidence, comparisons, and claim scope.
C1. The “world model”...
R1. We use “world model” in a restricted CT-specific sense: the latent state summarizes evidence observed along the axial sequence, predicts unobserved slice-level evidence in feature space, and supports factor-level intervention during report generation. Table 3 separates MFP-only, factor-aware, and full intervention-sensitive training under the same architecture and report-generation setup; Figure 2 evaluates the intended specialization of the state factors; and Table 4 and Appendix Table 11 examine selective report changes and non-target preservation under lesion-factor intervention. The persistence and linear-extrapolation baselines test whether future-feature prediction exceeds simple axial-continuity rules. We will clarify these evidence roles and the feature-space scope of the world state. Stronger controls against generic predictive pretraining are reported in A2.
C2. Relevant recent CT...
R2. We reviewed recent CT report-generation systems covering or closely related to the highlighted anatomy-guided, graph-based, region-guided, and grounding-based directions, including MvKeTR [1], Reg2RG [2], CT-GRAPH [3], and CT-AGRG [4]. Among them, CT-AGRG reports results using the same official CT-RATE report corpus and split as ours. We therefore include the directly comparable result below:
SliceWorld is higher than CT-AGRG on all shared metrics. The remaining systems provide cross-protocol context because they use materially different report corpora, splits, metrics, or auxiliary resources: MvKeTR evaluates CTRG-Chest-548K with a random split and retrieves reports from a CT-RATE report bank; Reg2RG evaluates region-structured RadGenome-ChestCT or CTRG-Chest-548K reports and uses segmentation masks; and CT-GRAPH pairs a deduplicated CT-RATE subset with RadGenome-derived reports, uses a different clinical metric, and additionally uses anatomical masks, large-scale 3D pretraining, and a 7B decoder. We will state these protocol conditions and restrict the “consistent improvement” claim to the directly comparable CT-RATE setting.
References for R2
[1] Deng, Xiwei, et al. "Mvketr: chest CT report generation with multi-view perception and knowledge enhancement." IEEE Journal of Biomedical and Health Informatics (2025).
[2] Chen, Zhixuan, et al. "Large language model with region-guided referring and grounding for CT report generation." IEEE Transactions on Medical Imaging (2025).
[3] Kalisch, Hamza, et al. "Ct-graph: Hierarchical graph attention network for anatomy-guided ct report generation." In 2025 IEEE/CVF International Conference on Computer Vision Workshops (ICCVW), pp. 6834-6843. IEEE, 2025.
[4] Di Piazza, Theo, et al. "Ct-agrg: Automated abnormality-guided report generation from 3d chest ct volumes." In 2025 IEEE 22nd International Symposium on Biomedical Imaging (ISBI), pp. 01-05. IEEE, 2025.
C3. Factor decomposition and...
R3. Because all factors share ht and encode related clinical signals, we expect residual overlap and target functional specialization rather than independence. Figure 2 shows that each intended factor is strongest on its corresponding probe, supporting preferential specialization but not disentanglement. Table 4 and Appendix Table 11 show that lesion-zero primarily changes lesion-related content, preserves non-target findings, and has much larger effects than uncertainty-zero and lesion-negative controls, supporting factor-selective latent report modulation. Here, “controllable” denotes lesion-factor intervention with the CT, other factors, decoder, and generation protocol fixed; “counterfactual” denotes paired factual and intervened model states rather than clinical causal ground truth. We will revise the terminology accordingly.
Q1. Can the authors compare...
A1. Please see R2, where we report the equal-protocol CT-RATE comparison with CT-AGRG and explain why the other representative systems use materially different evaluation settings.
Q2. Can the authors include...
A2. We add three matched controls under the same CT-RATE report-generation setting. The Mamba control is distinct from Table 3's +MFP: +MFP retains the shared three-factor SliceWorld architecture with the FAS and CF objectives disabled, whereas this control removes the factor heads and uses a single Mamba state.
Our feature-space predictive design and these comparison axes follow established directions: matched video pretraining favors feature-space over pixel-space prediction [5], while CT-RATE studies report gains from causal slice modeling over a direct 3D encoder [6] and slice-specific inter-slice modeling over a 3D-encoder variant [7].
SliceWorld is highest on all three metrics. The two predictive controls indicate that generic masked-slice or future-feature pretraining does not fully explain the gain, while the 3D-encoder control shows that a volumetric LLM prefix alone is insufficient. Alongside Table 3, the comparisons support the full predictive, factor-aware, and intervention-sensitive design.
References for A2
[5] Bardes, Adrien, et al. "Revisiting feature prediction for learning visual representations from video." arXiv preprint arXiv:2404.08471 (2024).
[6] Hamamci, Ibrahim Ethem, et al. "Ct2rep: Automated radiology report generation for 3d medical imaging." In International Conference on Medical Image Computing and Computer-Assisted Intervention, pp. 476-486. Cham: Springer Nature Switzerland, 2024.
[7] Lee, Changsun, et al. "Read like a radiologist: efficient vision-language model for 3D medical imaging interpretation." Medical Image Analysis (2026): 104077.
Q3. How much information...
A3. The requested cross-factor probes are reported in Section 4.4 and Figure 2, using the same shallow probe family for all three factors on held-out DeepLesion sequences:
Each intended factor performs best on its corresponding target, while the nonzero off-diagonal scores confirm residual information sharing. The results support preferential specialization, not independence or perfect disentanglement; we will revise the claim accordingly.
Q4. Can the authors test...
A4. Appendix Figure 4(b) provides a qualitative lesion-factor insertion example. We further evaluate this behavior on CT-RATE by pairing 50 positive and 50 negative factual generated reports for each of three findings and swapping their lesion factors in both directions while keeping anatomy, uncertainty, and the trained model fixed.
Across all three findings, most swapped reports change toward the donor label in both directions. The consistent pattern suggests that the lesion factor carries finding-related information and supports report modulation while the other factors remain fixed.
Q5. Can the authors report...
A5. We repeated the five Table 3 settings with three random seeds. Their averaged standard deviations are:
The consistently small standard deviations indicate limited run-to-run variation across all ablation settings.
The existing 100-case expert evaluation reports inter-rater agreement of κ=0.86. In the error analysis of the 100 generated/reference report pairs, 57% of cases are dominated by additional findings (e.g., medical-material mentions), 28% are dominated by omitted findings (e.g., lung opacity); the remaining 15% contain equal numbers of the two mismatch types. The most frequent subtypes are additional medical-material mentions and omitted lung-opacity findings.