- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 4
Read review
Summary
This paper proposes ANCHOR-GEN, a framework that uses a Diffusion Language Model (DLM) as an explicit clinical planner for chest X-ray radiology report generation (RRG), separating non-autoregressive anchor prediction from autoregressive report realization. It has three components: (1) a Diffusion Language Planner (DLP) that performs masked infill over a structured clinical canvas to predict grounded anchor fields such as disease existence, laterality, location, severity, and devices in a coarse-to-fine manner; (2) a Gated Planner-Memory Bridge (GPMB) that connects the planner and decoder through a dual channel, injecting anchor phrases as a textual prompt and planner hidden states as planner-aware visual evidence; and (3) an Anchored Causal Decoder (ACD), an autoregressive LLM that verbalizes the anchored signals into a coherent free-text report. The model is trained with a staged objective combining structured denoising, hierarchical coarse-to-fine supervision, and planner-decoder binding. Experiments on MIMIC-CXR, with supplementary results on IU X-Ray, report gains on NLG and CheXbert-based clinical-efficacy metrics, paired-bootstrap significance testing, and ablations over planner type, GPMB channels, and training objectives.
Strengths and weaknesses
Strengths
-
Clear and coherent methodological motivation. The separation of non-autoregressive structured planning from autoregressive realization is clean and well argued. The paper clearly explains the complementary roles of DLP, GPMB, and ACD, and the overall narrative is easy to follow from Figure 1.
-
A legitimate and clearly articulated combination of existing ideas. Under the General originality criteria, originality does not require every component to be new. Combining diffusion-based structured planning, a dual-channel planner-decoder bridge, and autoregressive report realization is a recognizable methodological contribution. The paper also provides a reasonable explanation of why these components may be complementary.
-
Reasonably complete experiments with significance testing. The comparison covers a broad set of baselines, and the headline gains are reported as statistically significant under paired-bootstrap resampling. The planner-type, bridge-channel, and training-objective ablations address several important design choices.
-
Informative ablations. The result that using the DLM directly as the decoder reaches only 0.343 F1 supports the decision to retain autoregressive realization. The observation that the Transformer-, LLM-, and BERT-based planners provide only small or negative gains, while the DLM planner produces a clearer improvement, is useful evidence for the structured diffusion-planning design.
-
Honest discussion of limitations. The conclusion acknowledges the dependence on a predefined clinical ontology and structured labels derived from reports, as well as the resulting limited coverage of rare, ambiguous, or nuanced findings
Weaknesses
-
The improvement over the strongest baseline is statistically significant but small. Against S2D-Align, the reported gains are at the third decimal: F1 improves from 0.608 to 0.612, precision from 0.613 to 0.616, recall from 0.606 to 0.609, BLEU-1 from 0.422 to 0.427, and ROUGE-L from 0.332 to 0.335. The paired-bootstrap result establishes statistical significance, but the paper does not report effect sizes or confidence intervals that would help assess the magnitude and practical meaning of these gains. In addition, the much larger improvement from the internal BASE model, 0.465 to 0.612 F1, should not be interpreted as the improvement over the strongest existing method.
-
The diffusion-specific originality is not fully isolated. I no longer regard the use of an established “predict anchors, then generate a report” paradigm as inherently insufficient: the DLP-GPMB-ACD combination is a legitimate form of originality under the General criteria. My remaining concern is that the experiments do not fully isolate whether the improvement comes specifically from diffusion-based planning rather than from additional structured supervision, staged objectives, or modeling capacity. The planner-type ablation is helpful, but a matched-capacity simpler structured predictor that emits the same 35 fields would provide a more decisive comparison.
-
The evidence for the significance and scope of the empirical gains is limited. The experiments support the chest X-ray RRG setting, but the main clinical-faithfulness conclusion is evaluated primarily through CheXbert label-presence metrics. The main results do not include RRG-specific metrics such as RadGraph, RadCliQ, or RateScore. Thus, it remains unclear whether the small improvement in CheXbert F1 corresponds to a meaningful improvement in entity/relation correctness or report-level factual quality. I do not require clinical deployment or domain-expert evaluation under the General criteria, but the claims should be scoped to the evidence actually provided.
-
The central faithfulness claim remains under-measured. The paper centers its contribution on improving clinical faithfulness, but planner-level factual accuracy, anchor usage, and hallucination analysis are placed in the appendix, while entity- and relation-level hallucination measures are not prominent in the main evaluation. Because faithfulness is a central methodological claim rather than merely application-side motivation, more direct evidence belongs in the main results.
-
Complexity and reproducibility remain concerns. The pipeline includes 35 structured fields, hierarchical coarse-to-fine supervision, two planner-decoder bridging channels, staged training objectives, and several thresholds. The manuscript reports implementation details and single-A40 execution, but reproducing the planner-data preprocessing—including deterministic consistency rules, the location-token set, and the canonical anchor bank—may be difficult without code or a more complete specification.
Reassessed under the General contribution criteria, this paper presents a technically coherent and clearly motivated combination of diffusion-based structured planning and autoregressive report realization. I regard this combination as a legitimate form of originality, and the planner-type, bridge-channel, and training-objective ablations provide useful supporting evidence. My main reservations are not the absence of deployment, domain-expert engagement, or cross-modality validation. Rather, they concern whether the central clinical-faithfulness claim is adequately supported and whether diffusion planning provides a meaningful advantage over a matched simpler structured predictor. The gain over the strongest baseline is small, while more direct entity/relation-level faithfulness and hallucination evidence is limited or relegated to the appendix. On balance, the reasons to reject slightly outweigh the reasons to accept, although stronger faithfulness evidence or a decisive matched-planner comparison could raise my assessment.
Questions
-
Evidence for the central faithfulness claim. Could the authors report RadGraph, RadCliQ, RateScore, and an explicit entity/relation-level hallucination rate in the main results? Clear improvements on these measures would show whether the DLM planner provides faithfulness gains that CheXbert F1 does not capture and would raise my significance assessment.
-
Magnitude of the gain over the strongest baseline. Beyond the paired-bootstrap p-value, could the authors report effect sizes or confidence intervals and discuss whether an F1 improvement from 0.608 to 0.612 is clinically or scientifically meaningful?
-
A matched simpler alternative. If the DLM planner were replaced with a lighter, matched-capacity structured predictor that emits the same 35 fields and receives the same structured supervision, how much would end-to-end performance change? This comparison would more directly quantify the incremental value of diffusion-based planning.
-
Scope of the claims. The current evidence mainly establishes performance for chest X-ray report generation. Is the intended contribution specifically scoped to CXR RRG? If broader medical report generation is claimed, what evidence supports transferring the fixed 35-field ontology, location tokens, and canonical anchor bank beyond this setting?
-
Contribution of the two GPMB channels. In the bridge ablation, the visual-only channel reaches 0.592 F1, which is already close to the dual-channel result of 0.612. Could the authors further characterize the marginal contribution of the textual-anchor channel on top of the visual channel and provide representative success and failure cases?
Limitations
The authors candidly discuss the dependence on a predefined clinical ontology and structured labels derived from reports, together with the resulting limited coverage of rare, ambiguous, or nuanced findings. This is appreciated. Under the General criteria, I do not additionally require evidence of clinical deployment or domain-expert engagement. My remaining limitations-related concerns are the small magnitude of improvement over the strongest baseline, reliance on CheXbert for the primary clinical evaluation, and the reproducibility burden of the structured preprocessing pipeline. These issues are already reflected in the assessment above and should not be double-counted.
Paper formatting concerns
None observed.
Final justification
I have read the rebuttal and both follow-up clarifications. The authors resolved the numerical and comparator inconsistencies in the additional analysis and provided a corrected comparison against S2D-Align using 1,000 study-level paired-bootstrap resamples.
The corrected results confirm that the gains on conventional NLG and CheXbert metrics are small but statistically significant—for example, BLEU-1 improves by 0.005 with a 95% CI of [0.001, 0.009], and CE F1 improves by 0.004 with a 95% CI of [0.002, 0.006]. More importantly, the faithfulness-oriented results show substantially larger and consistently supported improvements: RadGraph F1 increases by 0.080 [0.064, 0.097], RadCliQ decreases by 1.450 [-1.630, -1.270], RaTEScore increases by 0.120 [0.098, 0.141], and Report Halluc. decreases by 0.130 [-0.155, -0.105], corresponding to a reduction from 0.18 to 0.05. None of these confidence intervals crosses zero.
These results directly address the main score-changing condition in my review: whether the added complexity produces a clear clinical-faithfulness improvement beyond CheXbert. The planner ablation also provides useful, although not fully conclusive, evidence that the DLM planner contributes beyond the Transformer-, LLM-, and BERT-based alternatives. Under the General contribution criteria, I credit the combination of structured diffusion planning, gated planner-decoder bridging, and autoregressive realization as a legitimate form of originality.
Some concerns remain. The improvements on conventional metrics are marginal; the experiments do not completely separate the diffusion mechanism from structured supervision and staged training; the demonstrated scope remains chest X-ray report generation; and full reproducibility still depends partly on the promised release of code, annotations, and model weights. These are meaningful limitations, but after the corrected faithfulness analysis they no longer make the overall balance negative.
I therefore update my overall rating from 3 (Borderline Reject) to 4 (Borderline Accept) and my Significance score from 3 to 4.
Dear Reviewer 8ozo,
We sincerely thank you for the careful review and constructive suggestions, which help us improve the empirical analysis, positioning, and reproducibility of this paper. In the following, we provide detailed responses to your concerns.
A1: We agree with this assessment and would like to further clarify this comparison. Relative to
S2D-Align,Anchor-Genimproves both NLG and CE metrics by a small margin. Yet, we would like to point out that higher NLG and CE scores do not always correlate to reports in better quality, as the former mainly measures lexical overlap (n-gram based), so that models can obtain high scores by overfitting descriptive template texts; while the latter does not always accurately reflect report faithfulness via the CheXbert labeler. Our observations align well existing published studies [1, 2, 3]. To further support this observation, we conduct further comparisons withS2D-Alignwith respect to RadGraph F1, RadCliQ, RaTEScore, and Report Halluc., as is suggested in Q3, with results shown below.Compared with
S2D-Align,Anchor-Genimproves RadGraph F1 by 38.1%, where RadGraph F1 serves as a more fine-grained evaluator than that of the CE metric, further confirming that the promising NLG performance originates from accurate diagnoses rather than overfitting the patternized texts. For comparison on RadCliQ, our method reduces by 56.2%, a large improvement magnitude demonstrating stronger overall clinical consistency between the generated and ground-truth reports. Regarding the RaTEScore, which mainly measures the preservation of report-level clinical semantics,Anchor-GenoutperformsS2D-Alignby 26.7%. Finally, it reduces Report Halluc. by 72.2%, showing that the generated reports contain substantially fewer unsupported clinical findings, where this observation aligns well with our advantage on RadGraph F1 and RadCliQ. Collectively, these improvements demonstrate that the benefit ofAnchor-Genis more evident in clinically grounded and faithfulness-oriented evaluation than in conventional lexical-overlap metrics. Note that all gains in our main paper as well as the additional experiments pass paired bootstrap testing with p<0.05. We will add all aforementioned results and their corresponding discussions in the final revision of our paper.References in A1:
A2: We agree that the suggested two-stage RRG paradigm, which first predicts plans and then verbalizes them into final repors, is not newly proposed. To clarify the positioning of our method, we would to distinguish the main difference between these studies and
Anchor-Genvia further illustrations. Specifically, we notice that most existing methods are proposed before 2023, in the time when LLM-based RRG methods are not developed, meaning that these methods manage to handle the RRG task based on from-scratch training with dedicated small encoder-decoder models. Another notable aspects of these studies lies at their paradigm to model plan prediction via vanilla Transformer- or BERT-based architecutre, where our main difference herein is to use non-autoregressive paradigm to retain the hierarchical structures of clinically-grounded planning. To enhance the aforementioned illustrations for a better positioning ofAnchor-Gen, we will particularly add these discussions to the second paradigm of Sec. 2 in our revised paper. Moreover, to showcase the advantage of non-autoregressive paradigm against autoregressive ones, we report this comparison in Tab. 1 of our main paper, as is also shown below. Here, we highlight the best-performing and second-best results in boldface and with underlines, respectively.A3: We agree that the NLG and CheXbert-based CE metrics might be biased, and report the results with respect to RadGraph F1, RadCliQ, RaTEScore, and Report Halluc. (following LLM-RG4) below:
Here, we have already discussed the comparison between
Anchor-GenandS2D-Alignin A1, and further analyze the performance advantage against other methods:R2GenandR2GenCMNare two representative encoder-decoder RRG methods, where we notice that these methods still perform heuristicly andAnchor-Genobtains an average performance gain by 58.2%.R2GenGPTis one of the first LLM-based RRG methods, yet we observe that direct adaptation of LLMs for RRG does not always lead to better clinical accuracies, where this observation aligns well with the performance drop of all metrics in the comparison table.LLM-RG4further enhances RRG with various context input settings. While comparable hallucination rate is shown, its performance on more fine-grained clinical metrics are not as competitive.A4: We would like to clarify that we have included several details in Sec. 3 and Appendix A, but they might not be sufficiently salient for readers to notice. In our final revision, we will further enhance the illustration of Sec. 4. For your concerns of the code availability, we will release the code, annotations, and the corresponding model weights upon paper acceptance.
A5: We agree with you that the data issue is one of the limitations by the time we proceed this work, as the available datasets are mostly chest X-ray. In our subsequent research, we have successfully extend this paradigm to paranomic radiology datasets, where results show similar effectiveness for RRG in other modalities. For the ontology and canonical anchor bank under such a setting, we notice that the terminologies differ a lot in other modalities, and thus, some hyper-parameter details, e.g., the vocabulary size, the number of anchor fields, might be slightly different, but we still keep the same paradigm proposed in this paper. We hope this additional information could address your concerns.
A6: We would like to further clarify this. Essentially, the two channels serve different roles. Specifically, the planner-aware visual states preserve continuous confidence and field interactions through the residual bridge, while the textual channel explicitly enumerates which clinical concepts should be verbalized. The textual channel is most useful when a correct low-frequency anchor might otherwise be ignored by the decoder. It can fail when a false-positive anchor is retained, which is why the baseline with prompt injection, i.e.,
Prompt-Onlyin Tab. 3 (a), obtains lower scores.We hope that our responses address your concerns. Please feel free to let us know if any questions remain, and we would be happy to provide further clarification.
Best,