- Rating
- 2
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 1
- Significance
- 2
Read review
Summary
The authors introduce SOAR, a pre-training method for CT imaging. SOAR consists of three main components: organ-level masked reconstruction, organ-level vision-language alignment, and organ-level supervision, which are combined in one objective with the aim of pre-training a ViT vision encoder for downstream application. They experiment with multiple tasks and demonstrate performance superior to self-supervised baselines.
Strengths and weaknesses
I read the paper in detail and found several strengths and weaknesses:
Strengths:
- Experimental results including selected metrics are quite elaborate and conducted on multiple datasets.
- SOAR generalizes well to multiple downstream tasks.
- SOAR, in general, outperforms self-supervised baselines on the presented tasks.
- SOAR is well-motivated. The task of foundational ViT CT pre-training is relevant to the community and could potentially benefit multiple applications.
- The method is in general easy to follow.
- The authors claim that code will be available.
Weaknesses:
- Extremely underwhelming and confusing ablation studies. It is unclear to me how ‘replacing random patch masking with random organ masking improves multiple-choice accuracy from 85.76% to 88.64%’ (L314-315), given that Tab3 exclusively compares the number of classes used for masking, L_organ-super, and the use of organ-specific mask tokens in L_organ-recon, and L_organ-align. The method consists of three loss components: L_organ-super, L_organ-recon, and L_organ-align. There is no ablation on switching individual loss components off, which would yield insights into their necessity. Further, ablations of core components should be conducted on multiple downstream tasks.
- Missing baselines. Given that the model uses ground truth labels for pre-training, it does not classify as self-supervised. I, therefore, disagree strongly with the authors statement: 'SOAR can also be viewed as a self-supervised pre-training method, since it does not rely on manual anatomical annotations but instead uses automatically derived anatomical priors from medical image segmentation foundation models' (L100-103). Given that, it is essential to compare to supervised baselines, such as [1, 2, 3] or simply encoders of pre-trained anatomical segmentation models such as [4, 5, 6].
- Conceptual issues. The Organ-level Vision-language Alignment module is not based on reports, but rather on simple class labels and does therefore not account for abnormal structures and diseases. Further, simple alignment to an embedding derived from the class name is far from ‘vision-language alignment’. I am interested in seeing the performance of SOAR if their tokens derived from PubMedBERT are exchanged with simple, fixed class tokens. This needs to be ablated in detail.
- Missing downstream tasks. It would be interesting to see SOAR’s performance on segmentation and detection tasks.
- No statistical significance for ablation results. These are necessary, given low performance delta in Tab3.
- It is unclear whether their in-house esophageal cancer screening dataset will be release to the public.
- SOAR depends heavily on TotalSegmentator, which does not represent the state-of-the-art [5]. It is therefore inherently limited to CT (and MR) images.
In summary, the weaknesses clearly outweigh the strengths of this paper. In particular, the ablations are incomplete and the baseline selection is unfair, which prevents a valid assessment of SOAR's contribution. Although the paper is well-motivated and there is a clear need of foundational CT encoders in the medical community, I can not recommend to accept SOAR at NeurIPS.
[1] Varma, Maya, et al. "MedVAE: Efficient automated interpretation of medical images with large-scale generalizable autoencoders." arXiv preprint arXiv:2502.14753 (2025).
[2] Chen, Qi, et al. "Foundation VAEs for 3D CT Reconstruction, Augmentation, and Generation." arXiv preprint arXiv:2605.30893 (2026).
[3] Guo, Pengfei, et al. "Maisi: Medical ai for synthetic imaging." 2025 IEEE/CVF Winter Conference on Applications of Computer Vision (WACV). IEEE, 2025.
[4] Wasserthal, Jakob, et al. "TotalSegmentator: robust segmentation of 104 anatomic structures in CT images." Radiology: Artificial Intelligence 5.5 (2023): e230024.
[5] Xu, Murong, et al. "CADS: A Comprehensive Anatomical Dataset and Segmentation for Whole-Body Anatomy in Computed Tomography." arXiv preprint arXiv:2507.22953 (2025).
[6] He, Yufan, et al. "VISTA3D: A unified segmentation foundation model for 3D medical imaging." Proceedings of the Computer Vision and Pattern Recognition Conference. 2025.
Questions
Suggestion: Please compare to supervised baselines for fair comparison.
Suggestion: SOAR needs to be ablated in detail (each introduced component individually).
Suggestion: I would appreciate downstream experiments on segmentation tasks.
Limitations
yes
Paper formatting concerns
none
Final justification
As discussed in the rebuttal, I find the paper's framing issues to be deeply rooted. Even though the authors have backtracked on positioning SOAR as self-supervised, I believe that all experimental results require comparison against multiple fully supervised baselines - verification that goes beyond what can be done within the narrow time frame of the rebuttal period. Given that, I still favor rejecting the paper.
Dear Reviewer PZ3k, we sincerely thank you for your thoughtful and constructive feedback. We address each point below.
The apparent discrepancy arises because these results appear in different tables: 85.76% is the random-patch MAE baseline in Table 1, whereas 88.64% is the organ-level reconstruction model with 30 masked organs in Table 3. We will add the MAE baseline to Table 3 in the revised paper.
Regarding ablation studies of different losses, presented below, we performed the requested ablation study in the manuscript. Each component is isolated through a paired comparison. Δ denotes the change relative to the preceding configuration.
Following the reviewer’s suggestion, we further evaluated all six ablation configurations on pneumonia classification and CT-RATE abnormality detection. As shown below, the proposed SOAR (last row) consistently provides robust overall performance across VQA and detection tasks.
Best results are shown in bold, and second-best results are underlined.
We would like to clarify that SOAR does not use ground-truth anatomical labels during pretraining. As stated in Lines 100–103, manual organ annotations are unavailable for our pretraining dataset; instead, a frozen, open-source TotalSegmentator automatically derives coarse anatomical masks used only as auxiliary spatial priors, not as ground-truth supervision.
Among the six suggested baselines, MedVAE [1] provides a directly transferable CT encoder, whereas Foundation VAE [2] does not introduce or train a method-specific CT encoder and is contemporaneous work under the NeurIPS 2026 policy. MAISI [3] is a diffusion-based CT synthesis framework without a visual-token interface for downstream understanding and is therefore outside our scope. References [4–6] are segmentation foundation models. We therefore added two representative and directly comparable baselines: MedVAE [1] and TotalSegmentator [4]. We selected TotalSegmentator because it is the exact pseudo-label generator used by SOAR, making its encoder the most direct segmentation-only control for determining whether SOAR’s performance is inherited from segmentation pretraining.
As shown below, SOAR outperforms MedVAE by 0.55–14.17 points and the TotalSegmentator encoder by 1.60–7.30 points across all CT-RATE VQA metrics, confirming SOAR’s superior performance over both autoencoder- and segmentation-based baselines.
Each Δ denotes SOAR’s improvement over the corresponding baseline.
We agree that our pretraining objective does not use radiology reports and therefore does not explicitly inject disease or abnormality semantics. Instead, SOAR preserves fine-grained visual information in anatomically grounded visual tokens through reconstruction and structural learning. During downstream instruction tuning, the LLM learns to associate these visual features with disease concepts and findings. The superior performance across the downstream benchmarks reported in the paper demonstrates the effectiveness of this design.
Following the reviewer’s suggestion, we replaced the PubMedBERT-derived organ embeddings with fixed class tokens and retrained the encoder under identical settings. Presented below, the results on pneumonia and abnormality detection show that PubMedBERT-derived organ embeddings provide more effective supervision than simple class identifiers.
All results are AUC (%). Δ denotes the improvement of SOAR over the fixed-class-token model.
Detection: We would like to draw your attention to Tables 1-2 that evaluate SOAR on detection-oriented tasks, including anatomy and abnormality detection in 3D-RAD and AMOS-MM, scan-level disease detection, and 18-class abnormality detection on CT-RATE. Together, they assess whether SOAR representations capture the presence of anatomical structures and abnormalities.
Segmentation: We agree that the original evaluation did not include segmentation. SOAR is designed primarily to produce fine-grained visual tokens for CT understanding tasks such as VQA and report generation. We therefore initially focused on these understanding tasks. Moreover, because SOAR pretraining already includes an auxiliary segmentation loss, a segmentation evaluation could inherently favor SOAR.
To fully address your concern, we evaluated all frozen encoders on KiTS19 using the same segmentation decoder and training protocol. SOAR achieves the highest mean Dice score of 0.897, compared with 0.726 for MAE, 0.663 for CLIP, 0.681 for fVLM, 0.837 for ViSD, and 0.868 for VoCo.
We appreciate this suggestion. We performed paired t-tests on the per-example open-ended VQA scores and added the results to the original Table 3 of the manuscript. As shown in the table below, full SOAR significantly outperforms the ablated models on most metrics.
Numbers in parentheses indicate the number of masked organs used during pretraining. Superscripts report paired t-test significance against the full SOAR model in the last row: *p<0.05$, **p<0.005, and ***p<0.00005.
The in-house esophageal cancer screening dataset was obtained under a data transfer agreement with the providing hospital. It can be made available to qualified researchers through a standard and straightforward data transfer agreement process. We will clarify this procedure in the revised Data Availability statement and release our pretrained weights and source code.
We respectfully clarify that SOAR is not inherently tied to TotalSegmentator. It serves only as an offline pseudo-label generator and can be replaced by any compatible anatomical segmentation model without modifying SOAR’s architecture or objectives. Therefore, developing or using a particular state-of-the-art segmentation architecture is not a prerequisite of SOAR.
We selected TotalSegmentator because it is a mature and widely adopted community tool. According to its paper, it was validated on heterogeneous routine clinical CT data spanning different scanners, sites, protocols, body regions, and major pathologies. Importantly, its documented training data exclude CT-RATE, whereas CADS [5] was trained on 3,134 CT-RATE volumes, creating potential data overlap.
Finally, the present work is intentionally scoped to 3D CT understanding, as explicitly stated in the title; extending SOAR to other modalities remains future work.