- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper introduces RadOmni, a foundation model framework aimed at overcoming the inherent low soft-tissue contrast of Non-Contrast CT (NCCT) by progressively integrating multimodal clinical knowledge. The authors propose a four-stage curriculum consolidation strategy that sequentially injects structural priors from NCCT, cross-phase anatomical features from Contrast-Enhanced CT (CECT), semantic context from radiology reports, and diagnostic cues from pathology reports. Instead of joint training, the method employs a progressive layer-freezing mechanism and retains previous loss functions to prevent optimization interference and catastrophic forgetting. To facilitate this complex training pipeline, the authors curated Omni-CT10K, a proprietary dataset of over 10,000 multi-modal NCCT cases, and demonstrate the model's performance across various downstream medical tasks.
Strengths and weaknesses
Strengths Strong Clinical Motivation and Relevance: The paper addresses a highly practical clinical problem, the limited soft-tissue contrast of Non-Contrast CT (NCCT). The approach of injecting complementary knowledge from Contrast-Enhanced CT (CECT), radiology reports, and pathology reports perfectly aligns with real-world clinical diagnostic workflows, providing a highly logical foundation for the research.
Effective Curriculum Consolidation Strategy: The proposed four-stage progressive learning framework is well-designed. Rather than simply employing joint training, the authors thoughtfully implement a progressive freezing strategy. The ablation studies, particularly the effective rank analysis, successfully demonstrate that this strategy mitigates optimization interference and prevents catastrophic forgetting of previously acquired representations.
Significant Data Curation Effort: The curation of Omni-CT10K, which contains over 10,000 multi-modal data pairs (NCCT, CECT, reports, pathology, and masks), represents a massive undertaking. This comprehensive dataset serves as a robust groundwork for training the proposed omni-pretraining framework.
Weaknesses Critical Lack of Reproducibility due to Closed Dataset: While the paper positions RadOmni as a "Foundation Model," its core performance relies heavily on the proprietary Omni-CT10K dataset. Since this dataset is private and no representative samples are provided, the research community cannot verify the data quality or reproduce the foundation model's claimed capabilities.
Omission of State-of-the-Art Public Benchmarks: The external validation relies on the outdated MSD dataset, which is insufficient for proving the generalizability of a foundation model. The authors completely omit evaluations on recent large-scale public benchmarks. For instance, to truly validate the text-to-image semantic understanding and report generation capabilities, evaluating the model on datasets like CT-RATE (which provides over 40,000 NCCT-report pairs) is essential.
Insufficient Cross-Modal Validation on Open Data: To robustly justify the cross-phase knowledge transfer from CECT to NCCT (Stage 2), the framework must be tested on established public datasets that contain explicit NCCT-CECT pairs and organ/lesion masks, such as KiTS19 or relevant collections from TCIA. Relying primarily on internal benchmarks weakens the claim of strong cross-center generalization.
Marginal Methodological Novelty: The individual components of the four stages, Masked Image Modeling (S1), Logit Distillation (S2), and Learnable Query-based Contrastive Learning (S3, S4), are standard techniques in the field. While the orchestration of these methods into a single pipeline is commendable, the framework reads more like a heuristic combination of existing techniques rather than introducing a fundamentally novel 3D architectural design for medical foundation models.
Questions
-
Clarifying Methodological Novelty and Architectural Innovation The proposed four-stage curriculum integrates Masked Image Modeling (S1), Logit Distillation (S2), and Learnable Query-based Contrastive Learning (S3, S4). While the orchestration is logical, these are fundamentally standard techniques. Does RadOmni introduce any novel architectural modifications specifically tailored to the unique spatial properties of 3D medical volumes, or is the core contribution strictly the heuristic sequencing of these existing methods?
-
Strengthening Claims of Generalization via Modern Public Benchmarks The external validation relies heavily on the older MSD benchmark. Given that this is positioned as a "Foundation Model" for NCCT, why were more recent, large-scale public datasets omitted from the evaluation? To substantiate the claim that RadOmni is a generalized foundation model, it is highly recommended to evaluate it on contemporary large-scale benchmarks. For the cross-phase transfer (CECT to NCCT in Stage 2), please provide experimental results on public datasets that contain explicit NCCT-CECT pairs and masks, such as KiTS19 or relevant collections from TCIA. For report-guided semantic learning and report generation tasks, validating the model on the recently released CT-RATE dataset (which contains over 40,000 NCCT-report pairs) would significantly strengthen the paper's claims.
-
Addressing Reproducibility and the Closed Dataset A major pillar of this work is the curation of the Omni-CT10K dataset. However, since this dataset is private, how can the research community verify the data distribution, reproduce the foundation model's baseline, or build upon this framework? The lack of access to Omni-CT10K limits the paper's impact and reproducibility. While privacy constraints are understandable, please provide highly detailed statistical distributions of the dataset. Furthermore, strongly consider releasing the pre-trained weights of RadOmni, the source code for the 4-stage training pipeline, and potentially a small, anonymized "toy" subset of the data so peer researchers can validate the methodology.
-
Computational Overhead of the Curriculum Strategy The ablation studies convincingly argue that the 4-stage progressive freezing strategy prevents the segmentation performance degradation seen in joint training. However, what is the computational cost (e.g., total GPU hours, memory footprint) of this sequential 4-stage pipeline compared to a single-stage joint training approach? Please include a brief computational complexity analysis (efficiency vs. performance trade-off). This will help readers understand if the marginal gains in certain downstream tasks justify the potentially massive computational overhead of training a model through four distinct, cumulative stages.
Limitations
The authors have not adequately addressed the limitations of their work, as a dedicated "Limitations" section appears to be missing from the manuscript. I strongly recommend adding a section that critically discusses the boundaries and constraints of the proposed framework. Specifically, the authors should explicitly address the implications of the points raised in the "Weaknesses" sections above.
Paper formatting concerns
.
Final justification
I thank the authors for their comprehensive rebuttal and the extensive additional experiments (e.g., CT-RATE, PLCC, and computational cost analysis). Most of my concerns have been successfully addressed. I will update my final score accordingly.
We appreciate your thoughtful feedback and accolades on our contribution: "Strong Clinical Motivation and Relevance", "Well-designed Curriculum Consolidation Strategy", and " with ablation studies that "successfully demonstrate". We also value your acknowledgment that the curation of Omni-CT10K "represents a massive undertaking" and "serves as a robust groundwork." Below, we address each of your concerns point by point.
Q1. The external validation on recent large-scale public benchmarks CT-RATE.
Response: We have added experiments on CT-RATE using its official data split and the zero-shot diagnosis protocol of fVLM. To ensure a controlled comparison, we retain the same contrastive-learning framework, text encoder, preprocessing, and evaluation protocol, and replace only the visual backbone and its initialization with the nnUNet encoder pretrained by RadOmni and evaluate zero-shot text-to-image semantic understanding task. As shown in the table, RadOmni outperforms CT-CLIP, fVLM, and ViSD-Boost across Precision, ACC, F1, and AUC, providing further evidence that RadOmni learns transferable representations on large-scale public NCCT-report data. We interpret this result cautiously, since our data construction is focused on abdominal colorectal cancer; thus, validation on CT-RATE serves only as supplementary evidence of transfer potential, not conclusive proof of cross-organ generalization.
Q2. Cross-Modal Validation on Open Data.
Response: We additionally evaluated RadOmni on two public multiphase CT datasets, the Primary Liver Cancer CECT (PLCC) dataset [ref1] and TriALS [ref2]. PLCC provides liver and lesion masks across NCCT, arterial, venous, and delayed phases, and TriALS, which provides liver-lesion annotations for NCCT and venous phases. Following the standard nnUNet protocol, we conducted 5-fold cross-validation on both datasets. The results show consistent improvements from RadOmni pretraining across both organ and lesion segmentation, and across both non-contrast and contrast-enhanced phases. Notably, on PLCC, the NCCT lesion Dice with RadOmni initialization reaches 59.06, surpassing the arterial-phase baseline without pretraining (58.82). This further suggests that the cross-phase knowledge introduced during pretraining can effectively enhance NCCT representations, and that this benefit is not limited to internal data.
Ref1: Comprehensive multi-phase 3D contrast-enhanced CT imaging for primary liver cancer. Scientific Data, 2025.
Ref2: TriALS: Triphasic-Aided Liver Lesion Segmentation Benchmark in Non-Contrast CT. arXiv, 2026.
Q3. The novelty of the proposed method.
Response: We would like to clarify that the main contribution of this work lies not in the individual techniques used at each stage, nor in introducing a new 3D architectural block, but in two main aspects. (1) New problem formulation. Prior work typically focuses on a single paradigm, such as self-supervised learning, supervised pretraining, or vision-language pretraining. In contrast, our goal is not to pursue isolated SSL/VLP/SP, but to address the information-limited nature of NCCT in real clinical practice by systematically leveraging clinically co-occurring and complementary supervision, including CECT, radiology reports, and pathology reports, to enhance NCCT representations, while relying on NCCT alone at inference time. We believe this clinically motivated, NCCT-centered omni-pretraining formulation is itself an important contribution. (2) New training paradigm. Our training paradigm is neither simple joint training nor plain sequential training. Instead, it is designed to stably organize heterogeneous supervision, accumulate knowledge, and integrate it into a single model. Specifically, the progression from Stage 1 to Stage 4 is not a heuristic stacking of objectives, but follows a multi-dimensional increase in supervision difficulty: supervision becomes less directly grounded in the image, more semantically abstract, and more prone to optimization conflict. Based on this progression, later stages retain earlier objectives and progressively freeze shallow or intermediate representations to reduce interference with previously learned visual and structural knowledge and to mitigate forgetting. Compared with joint training, curriculum consolidation consistently improves both internal and external performance, for example increasing internal tumor segmentation from 56.76 to 63.83 Dice and external zero-shot T/N staging from 68.20/54.82 to 74.64/64.61. The stage-wise ablations and effective-rank analysis further show that retaining earlier objectives and progressive freezing reduce optimization interference and representation collapse. In this sense, the methodological novelty of our work lies not in any isolated module, but in a principled framework for ordering, accumulating, and stably consolidating heterogeneous supervision.
Q4. Code, model, and data availability.
Response: To improve reproducibility, we will release the code and pretrained model weights, and we have already provided the code and representative anonymized samples to the AC via an anonymous link. Regarding the dataset, Omni-CT10K contains retrospective clinical imaging data together with associated multimodal clinical information, and therefore cannot be made fully public because of patient privacy protections, institutional data governance, and IRB-related restrictions. Researchers may request access to anonymized data and supporting clinical information by contacting the corresponding author. Access will be granted subject to institutional approval, IRB approval where applicable, and a signed data-use agreement, and will be limited to non-commercial academic research. We will include a formal data availability statement in the revised manuscript to clearly describe this access process.
Detailed statistical distributions of the dataset are also provided.
Q5. Efficiency vs. performance trade-off.
Response: Table R8 compares the GPU hours and peak memory of RadOmni and joint training. The main computational cost lies in S1, which is shared by both strategies; thus, the relevant overhead comparison is for the post-S1 stages. Under our setting, RadOmni adds only 97 GPU hours over joint training, corresponding to about 12 extra wall-clock hours in our 8-GPU setup. RadOmni also has a lower peak memory footprint than joint training, because progressive freezing in S2–S4 reduces the number of trainable parameters. To contextualize this cost, we further report zero-shot generalization on the external ExtBenchB benchmark in addition to the internal ablation results. RadOmni shows consistent improvements on both internal tasks and the external benchmark, with especially notable gains on the external data. Overall, compared with joint training, RadOmni delivers stable internal and external performance gains at the cost of only 12 additional wall-clock hours. This overhead arises only during training; inference cost remains identical. We will add this efficiency analysis to the revised manuscript to better clarify the performance–computation trade-off.
Q6. Limitations.
Response: We thank the reviewer and agree that the limitations should be stated more explicitly. The current manuscript already discusses several limitations in the conclusion, but they are not organized under a dedicated “Limitations” heading and may therefore be easy to overlook. We will revise the paper to present them in a clearly marked Limitations section.