- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper studies the mixture strategies optimization for different domain images (CT, MRI, and PET). They use MAE reconstruction loss to show that power-law scaling of different domains are different, and the cross-domain transfer is asymmetric. They show that, for different domains, the gain of more data is different and the information that can be transferred to other domain is also different. The extracted scaling law can be used to direct data allocation in large scale.
Strengths and weaknesses
Strengths:
- The motivation of this paper is good.
- Modeling both domain-specific scaling behavior and asymmetric cross-domain transfer is intuitive.
- The final allocation improves MAE loss across budgets and domains, and also improves downstream classification and segmentation after fine-tuning, indicating the effectiveness and generalizability of the proposed method.
Weaknesses:
- The scaling law is built on the MAE reconstruction loss, which is a proxy of knowledge transfer, not a semantic/clinical knowledge transfer. MAE loss itself is problematic when used for medical image. Because a model may reconstruct target-domain images refering to MAE well because it learned: low-level intensity statistics, texture, and easy background/foreground patterns. However, this does not guarantee the model learned clinically useful features (e.g. small lesions, abnormality recognition, and disease-relevant representations). These details can be critical for downstream medical task.
- The related work mentions RegMix. But experimentally, they do not seem to compare against adapted versions of this method. For example, RegMix treats data mixture selection as a regression problem: train many small proxy models on different mixtures, record performance, fit a regression model to predict performance for unseen mixtures, then choose the best predicted mixture for large-scale training. I think RegMix can be adapted to this paper easily.
- The foundation training is usually on large-scale dataset. But their method performance is best when the budget is 50K scale, and the improvement on 200K scale is very limited. This makes me suspect the meaningful of this method in very large scale training.
Questions
Given that the 200K gains nearly vanish, what's the argument that transfer-aware allocation still matters at the scales practitioners actually pretrain unified models at?
Limitations
The improvement on 200K is limited.
Paper formatting concerns
"AdamW [?]" in A.4 (line 551).
Final justification
I am satisfied with the rebuttal. I insist on my positive review.
We thank the reviewer for the positive and constructive assessment and for viewing the paper as a borderline accept. We appreciate the reviewer’s recognition of the importance of transfer-aware data allocation for heterogeneous 3D medical pretraining and of the potential value of the proposed scaling-law framework. The remaining concerns focus on three important questions: whether MAE is an appropriate proxy for clinically useful representation learning, how our approach compares with learned mixture optimization such as RegMix, and whether the benefit remains practically relevant as the pretraining budget increases. We address each point below with additional analyses, experiments, and corresponding manuscript revisions.
W1. MAE is a proxy rather than a direct measure of clinical knowledge
We agree that low MAE reconstruction loss alone does not establish semantic or clinical knowledge. A model may reduce reconstruction error by learning intensity distributions, texture, or background-foreground structure without necessarily capturing small lesions or disease-relevant abnormalities. We will therefore revise the manuscript to describe MAE explicitly as a controlled proxy for selecting the pretraining mixture, rather than as a direct measure of clinical validity.
In parallel, we also evaluate whether this proxy transfers beyond reconstruction through downstream tasks that require clinically relevant representations. The MAE-derived Transfer-Aware mixture achieves the strongest results across three classification benchmarks and six organ or lesion segmentation benchmarks spanning CT, MRI, and PET. In particular, it improves over Data-Proportional pretraining on all six segmentation tasks, including brain tumors, head-and-neck tumors, and brain hemorrhage, with p<0.01. Because these tasks require abnormality recognition and spatially accurate delineation of pathological regions, the results provide task-specific evidence that the learned representations capture information beyond low-level reconstruction statistics.
We do not claim that MAE is universally optimal or that these results establish full clinical validity. Rather, the downstream results show that MAE provides a useful mixture-selection proxy to extract clinical-meaningful representation which can be transfered to enhance diverse downstream clinical tasks. We will make this scope and limitation explicit in the revision.
W2. Comparison with RegMix
We agree that RegMix can be naturally adapted to our setting. We therefore implemented a RegMix-style baseline using anchored and Dirichlet-sampled mixtures under the same 5% minimum-allocation constraint. Each mixture uses the same 3D MAE proxy model and is evaluated on all six target domains. We fit one LightGBM regressor per target domain, average the six predicted losses, and search the predicted mixture landscape to obtain the RegMix allocation.
Mean reconstruction MAE across six domains (↓):
The comparison is budget-dependent. Transfer-Aware reduces mean MAE relative to RegMix by 14.3% at 10K and 19.5% at 100K. RegMix is slightly better at 50K by 3.3%, while the two methods are effectively tied at 200K.
More broadly, the gaps among Transfer-Aware, RegMix, Uniform, and Data-Proportional become small at 200K, suggesting that the strongest strategies are approaching an irreducible-loss or capacity-limited regime in which mixture selection has less influence. We therefore use the 100K budget for downstream evaluation: it remains within the data-limited regime, exhibits clear separation among mixture strategies, and allows the effect of allocation quality on learned representations to be evaluated before performance becomes obscured by near-saturation.
At the 100K budget used for downstream evaluation, Transfer-Aware outperforms RegMix on all five segmentation tasks for which RegMix results are available, with gains ranging from +0.5 to +2.3 Dice and an average improvement of +1.7 Dice. The gains are particularly clear on AMOS-CT (82.5 vs. 83.1), BraTS-T1 (55.1 vs. 53.0), BraTS-T2 (65.4 vs. 63.1), HECKTOR (71.1 vs. 69.3), and BHSD (61.2 vs. 59.3). On classification, Transfer-Aware achieves higher accuracy on OASIS-1 and SynBrain-PET, whereas RegMix performs better on OrganMNIST3D and obtains a higher OASIS-1 AUC. Thus, RegMix remains competitive on classification, while Transfer-Aware shows more consistent improvements on dense organ and lesion segmentation.
The two methods make complementary modeling trade-offs:
Thus, our contribution is not simply another predictor of the optimal mixture. RegMix learns the correspondence between mixture weights and loss, whereas our framework provides a structured model of how knowledge transfers directionally among heterogeneous 3D CT, MRI, and PET domains. It yields reusable, budget-dependent allocations h∗(T) and explains which domains act as transfer hubs and which require direct investment as islands. We view this interpretability and the consistent dense-prediction improvements as the main advantages of our approach, while recognizing RegMix’s greater flexibility in modeling nonlinear mixture interactions. It will be a great extension or become our next step to integrate the transfer knowledge modeling into Regmix-like approach and modeling the non-linear interaction with the cross-domain knowledge between 3D medical imaging.
W3. Relevance to large-scale foundation-model training
We agree that the reduced separation at 200K requires clarification. The observed saturation is specific to the relatively small, fixed-capacity proxy model used for mixture estimation; it should not be interpreted as a universal performance ceiling for larger foundation models.
Our intended workflow is to use a small proxy model to efficiently estimate the relative scaling behavior and directed transfer among the available 3D imaging domains before committing compute to full-scale pretraining. At the current six-domain data scale, this proxy is sufficient to recover a meaningful mixture: Transfer-Aware provides clear reconstruction-loss improvements at 100K, and the resulting encoder consistently improves downstream segmentation over RegMix. The purpose of the proxy is therefore to identify useful allocation structure, rather than to reproduce the ultimate loss floor of the final foundation model.
The narrowing gaps at 200K indicate that the current proxy model is approaching its capacity-limited floor. When model capacity is increased, this floor and the allocation-sensitive data regime are expected to shift, which motivates scaling the data population together with model size, as also practiced in recent large-scale vision foundation models such as DINOv3 and Perception Encoder [7,8]. A larger model may therefore continue to benefit from additional data after the smaller proxy has saturated.
We nevertheless do not assume that the exact fitted parameters or mixture remain invariant across model sizes. Model scaling may change Ei, βi, and potentially τij. Our present results establish that small proxy models can provide useful mixture guidance within the evaluated regime; jointly modeling model size, data budget, and mixture through L(N,h,T) is an important extension for validating transfer to substantially larger foundation models.
References:
[7] Siméoni, Oriane, et al. "Dinov3." arXiv preprint arXiv:2508.10104 (2025).
[8] Bolya, Daniel, et al. "Perception encoder: The best visual embeddings are not at the output of the network." Advances in Neural Information Processing Systems 38 (2026): 60884-60937.