This paper proposes Pan-FM, a pan-organ foundation model for seven organs, aiming to address the common problem of missing organs in real-world biomedical data. Pan-FM introduces a saliency-guided masking strategy, which adaptively masks dominant organs according to the model’s attention distribution, thereby encouraging the model to learn more balanced cross-organ representations. Experimental results show that Pan-FM overall outperforms multiple self-supervised learning baselines across 13 disease groups and 14 individual disease prediction tasks, and demonstrates stronger robustness under both single-organ and multi-organ missing scenarios.
Strengths and weaknesses
Strengths:
- Pan-FM focuses on the problem of missing organs in multi-organ medical imaging foundation models, which aligns well with real clinical scenarios and has strong practical value.
- Pan-FM observes the dominant-organ shortcut learning bias in multi-organ self-supervised pre-training, and proposes Saliency-Guided Masking to mitigate this issue, which also shows a certain degree of transferability.
- Pan-FM conducts robustness evaluations across multi-disease groups, individual disease prediction tasks, and different organ-missing settings. The results show that Pan-FM has advantages in both overall prediction performance and missing-organ robustness.
Weaknesses:
- The generalization validation is limited. Since Pan-FM aims to serve as a multi-organ foundation model for real clinical scenarios, validation on a single data source is insufficient to fully demonstrate its generalizability across centers, imaging devices, or populations.
- The input format is biased toward low-dimensional features rather than raw medical images. This may limit its direct comparability with existing vision-based medical foundation models.
- The core assumption of SGM is to use the attention distribution to measure organ importance. However, whether attention is stable and whether it truly corresponds to biologically meaningful organ contributions still require further validation.
Questions
- CAPE is used to balance the dimensionality across different organs. The author should clarify whether not balancing the organ dimensions would affect the results. An ablation study on CAPE is also missing.
- Figure 3 shows that adipose is the dominant organ, and removing it leads to a significant performance drop, while removing the pancreas has almost no effect. In Figure 4, w/o brain and liver has only a limited impact, and Pan-FM even underperforms DINOv2 w/o spleen. Does this suggest that using only a small subset of dominant organs can achieve performance nearly comparable to that obtained with all seven organs?
- The relative improvement over DINOv2, denoted by Δ, in the last row of Table 2 is somewhat unusual. A more common presentation would be to report the absolute improvement over the second-best method.
- In Figure 5(b), there are cases where the performance under single-organ removal is even lower than that under two-organ removal. For example, w/o Adipose=0.647 < w/o Adipose+Spleen=0.654. This raises concerns about the contribution of the complete multi-organ input.
- The paper lacks comparisons with recent methods (2024, 2025, and 2026). The baselines are mainly foundation models from the general vision domain, whereas direct comparisons with medical imaging foundation models are missing.
Limitations
Yes
Paper formatting concerns
N/A
Final justification
My major concerns still partly remain. Adding one external application is somewhat still limited, and direct quantitative measures are desired for illustrating the attention stability and biological implication. Therefore, my rating remains the same.
We thank the reviewer for their detailed and insightful feedback, and for recognizing the strong practical value of addressing missing organs, the dominant-organ shortcut learning bias and transferability of SGM, and the robust evaluation. We address each concern below.
Weaknesses
W1: Generalization is validated on a single data source, insufficient across centers, devices, or populations.
We thank the reviewer for this important concern. We have added an external evaluation on ADNI, which differs from UK Biobank in population, scanner fleet, acquisition protocol, recruitment, and disease prevalence. Please refer to USq3-W2/Q2 and h3iE-Q2 for the full experimental setup and implementation details.
Using only brain features, with six of the seven organs absent, Pan-FM achieves 0.921 ± 0.007 test balanced accuracy, outperforming DINOv2 pre-training (0.896 ± 0.012), training from scratch (0.865 ± 0.009), and classical MLP and SVM baselines. No architectural modification is required. These results provide evidence that Pan-FM transfers across cohorts and imaging settings and remains effective under extreme organ missingness.
W2: The input is low-dimensional features rather than raw images, limiting comparability with vision medical FMs.
Thanks for raising the concern. The current study uses imaging-derived features to enable a controlled investigation of joint multi-organ representation learning under realistic organ missingness. Nevertheless, the learned Pan-FM representation is transferable across cohorts: as shown by the external ADNI evaluation in W1, our UK Biobank-pretrained multi-organ model transfers well to a single-organ brain cohort without architectural modification.
To directly assess whether Pan-FM and SGM extend beyond imaging-derived features, we further developed a raw-imaging version using seven available UK Biobank modalities: total-body DXA, cardiac cine MRI, brain T1 MRI, liver MRI, pancreas MRI, and left and right retinal OCT. Each modality is tokenized using a modality-specific 2D or 3D convolutional encoder, after which CAPE aggregates the resulting image tokens into a fixed set of organ tokens. The subsequent multi-organ Transformer and SGM are unchanged. In particular, SGM operates only on organ-level token groups and is therefore agnostic to whether these tokens originate from tabular features or raw images.
The raw-imaging cohort contains 137,716 subjects, more than 3× the 40,689 subjects used in the current paper, and exhibits substantially more severe natural missingness. Only 1,350 subjects (1.0%) have all seven modalities, compared with 33% complete cases in the feature-based setting.
Preliminary linear-probing results show that Pan-FM consistently outperforms its DINOv2 counterpart under both natural missingness and additional organ dropout:
These results are evaluated on a held-out test set of 2,100 subjects, comprising 1,300 disease cases and 800 controls. Only 17 subjects (0.8%) have all seven modalities. The Drop-k settings further remove modalities on top of this natural missingness. This evaluation is therefore substantially more challenging than the current setting in the paper, where 33% of participants have complete seven-organ data. The heavier missingness likely contributes to the lower absolute performance. Nevertheless, Pan-FM maintains a consistent advantage over DINOv2 across all evaluated settings.
Overall, these results show that SGM is not specific to imaging-derived features and remains effective across heterogeneous raw imaging modalities, including MRI, DXA, and retinal OCT. The raw-imaging extension also broadens the practical applicability of Pan-FM to downstream datasets that provide raw scans but do not share an identical pre-extracted feature pipeline. We will include these new results in the revised paper.
W3: Whether attention is stable, and whether it reflects biologically meaningful organ contributions.
Appendix Fig. 15 evaluates the stability of the learned organ saliency throughout pre-training. The saliency trajectories evolve progressively rather than changing abruptly, and Pan-FM with SGM exhibits smoother trajectories and smaller fluctuations than DINOv2. This suggests that SGM promotes a more stable allocation of attention across organs.
Appendix Fig. 16 assesses biological relevance through leave-one-organ-out disease prediction. Removing different organs causes disease-specific performance drops. Adipose contributes broadly across several disease groups, whereas brain removal most strongly affects mental and behavioural disorders. These patterns suggest that the attention-derived [CLS] representation captures biologically meaningful, disease-dependent organ contributions.
Questions
Q1: An ablation on CAPE is missing. Would not balancing the organ dimensions affect the results?
We thank the reviewer for this important suggestion. The original organ dimensions are highly imbalanced: Brain and Heart contribute 87.3% of all 228 IDPs, with a largest-to-smallest ratio of 39.7:1. CAPE maps the seven organs from (119,80,16,4,3,3,3) IDPs to (64,32,16,4,4,4,4) tokens, reducing this ratio to 16:1 and the combined Brain&Heart share to 75.0%.
We therefore compare DINOv2 and Pan-FM with either feature-wise tokenization or CAPE, while keeping all other settings fixed.
CAPE improves AUROC by 1.1 points for DINOv2 and 0.6 points for Pan-FM, supporting its effectiveness in reducing organ-dimensional imbalance. Pan-FM also outperforms DINOv2 under both tokenization schemes. Note that the SGM gain is larger under the more imbalanced feature-wise setting, at 2.5 points compared with 2.0 points using CAPE, suggesting that SGM is helpful when organ imbalance is more severe. Overall, CAPE and SGM provide complementary benefits.
Q2 and Q4: Some organs have minor effect. Can a small subset of dominant organs match all seven? Why can removing two organs occasionally outperform removing one?
Thank you for this careful observation. The small average effect of removing organs such as the pancreas in Fig. 4 partly results from averaging over all 13 disease categories. Appendix Fig. 16 provides a leave-one-organ-out analysis showing that organ contributions are disease-specific. For example, removing the pancreas reduces AUROC for mental and behavioural disorders by 0.011 and 0.014 under LP and FT, respectively. Its smaller overall contribution is also expected given that it is represented by only four tokens, compared with 64 for brain, 32 for heart, and 16 for adipose.
Tables 10 and 12 show that Pan-FM AUROC decreases progressively from all seven organs to removing one, two, and three organs. Likewise, Figs. 7 and 8 show that removing any individual organ lowers the mean balanced accuracy under both LP and FT. Thus, even organs with modest average effects provide complementary disease-specific information, and the complete seven-organ input achieves the strongest overall performance.
Q3: Reporting the relative improvement over DINOv2 is unusual.
Thank you for this suggestion. Reviewer h3iE raised the same concern (h3iE-W2) for the full discussion. In the revised version, we will additionally report the absolute improvement in the revision.
Q5: The paper lacks comparisons with recent methods (2024 to 2026) and with medical imaging FMs.
Thank you for this suggestion. Most existing medical imaging FMs are trained for a single organ or modality, whereas Pan-FM targets joint subject-level multi-organ learning under missingness, making a direct comparison in the current feature-based setting difficult. We therefore use controlled comparisons with six SSL methods under the same backbone, tokenizer, and training data, together with 35 single-organ baselines shown in Tables 16 and 17. In addition, our new raw-imaging Pan-FM can be transferred to downstream single-organ imaging datasets, enabling more direct comparisons with existing organ-specific imaging medical FMs. We will expand the discussion in the revision.