- Rating
- 4
- Clarity
- 3
- Confidence
- 3
- Originality
- 2
- Quality
- 3
- Significance
- 3
Read review
Summary
The paper selects regions worth cropping based on Anatomy-awareness, Informativeness, and Diversity, then places them into a bank. The paper presents two versions: VolumeProbe-Lite: Uses only simple information from the image itself, such as location, boundary distance, gradient, and entropy. VolumeProbe-Feat: Uses a frozen visual encoder to extract features, then determines which regions are more meaningful based on those features.
Strengths and weaknesses
Strength
-
This method is plug-and-play and widely applicable. It doesn't introduce learnable parameters, thus it's compatible with existing 3D SSL frameworks.
-
The empirical evaluation is quite comprehensive. The paper uses various backbone networks and tests VolumeProbe on three tasks: segmentation, classification, and registration. It achieves good results with few labels.
-
Detailed experiments are provided, including ablation analysis, pruning occupancy analysis, representation diversity analysis, and early learning curve analysis.
Weaknesses
-
It's more like a reasonable sampling engineering improvement than a strong algorithmic contribution. Essentially, this method first builds a crop-center bank offline, then samples a sub-volume from this bank during training, without modifying the SSL backbone or the training objective.
-
It lacks theoretical guarantees explaining why this bank selection objective should improve SSL representation.
-
Q2 concerns frozen MedicalNet feature variance; does it also depend on an external feature extractor?
-
If the featured version depends on a strong external encoder but doesn't improve it, it suggests the framework's ability to utilize semantic cue may be limited.
-
The paper's limitations also acknowledge that the current probe bank is offline and static, unable to adapt to the dynamic nature of model training.
-
For classification, reporting only accuracy is insufficient; AUC, F1, sensitivity, and specificity should be included.
Questions
1.Why does the performance of the Feature variant consistently fail to surpass Lite? Does this indicate that the frozen feature extractor is not extracting effective semantic information?
2.Q2 concerns frozen MedicalNet feature variance; does it also depend on an external feature extractor?
3.For scans of chest, brain, orthopedics, breast, and dental areas, are the current priors still valid?
Limitations
Details are in the weaknesses
Paper formatting concerns
None
We appreciate the reviewer’s favorable evaluation of VolumeProbe’s plug-and-play applicability, broad empirical evaluation, and detailed mechanistic analyses. In response, we clarify the empirical scope of the contribution, disentangle the role of external feature extractors, and add comprehensive classification metrics.
Summary of Key Concerns and Main Responses
W1: The contribution of sampling engineering.
We appreciate this constructive feedback. We agree that VolumeProbe is simple and does not alter the SSL backbone or objective. Its contribution is to identify sub-volume observation policy as an overlooked bottleneck, formulate it as a where-to-look problem, and demonstrate across multiple SSL frameworks that better allocation of a fixed crop budget consistently improves downstream transfer. The lightweight offline design is thus a deliberate plug-and-play choice rather than an ad hoc sampling heuristic.
W2: Theoretical guarantees.
Thank you for this thoughtful comment. We agree that VolumeProbe does not provide a formal theoretical guarantee. Instead, it is motivated by controlled studies showing that higher-quality crops improve downstream transfer, while ablations and cross-framework results empirically validate the proposed objective. We will clarify this empirical scope in the Limitations and leave formal analysis to future work.
W3: Dependency of external feature extractor.
Please see Q2.
W4: Use of semantic cues.
Please refer to Q1.
W5: Offline and static probe bank.
We agree that the offline probe bank cannot adapt to the model’s evolving learning dynamics, and we acknowledge this as a limitation. The static design is a deliberate choice to preserve simplicity and avoid model-dependent online scoring and substantial recurring overhead. Developing online, training-aware probe selection is an important direction for future work, which has been discussed in Limitations.
W6: Additional classification metrics.
We thank the reviewer for suggesting this additional analysis. Our original evaluation followed the downstream protocols of VoCo [1] and S2DC [2], which reported classification performance using accuracy only. We agree that additional metrics provide a more comprehensive evaluation. We therefore further report macro-averaged one-vs-rest AUC, Macro-F1, sensitivity, and specificity, as follows.
Table R1. Additional classification metrics on the classification task.
As reported, VolumeProbe consistently improves all four metrics across VoCo, S2DC, and MedGMAE. The improvements reach +0.28 AUC, +0.88 Macro-F1, +0.88 sensitivity, and +0.58 specificity, consistent with the accuracy gains reported in Table 1. These results confirm that VolumeProbe improves classification performance beyond accuracy across both threshold-dependent and threshold-independent metrics.
We will add these results and the complete evaluation protocol to a new Appendix section titled Additional Classification Metrics on CC-CCII.
Q1: Analysis of Feature vs. Lite variant.
We appreciate the reviewer’s comment on improving the analysis of our results. We first clarify that MedicalNet is used only for the diagnostic Q2 proxy in the motivation study, whereas VolumeProbe-Feat uses a frozen 3DINO-ViT encoder. VolumeProbe-Feat still consistently improves over random sampling, suggesting that the frozen encoder does provide useful semantic information, but it does not reliably outperform VolumeProbe-Lite. We attribute this to three possible factors:
Hence, under the current normalized 3D volumetric setting, the intrinsic cues in Lite appear more directly aligned with informative sub-volume selection. This does not indicate that semantic cues are ineffective, but rather that the current frozen-feature instantiation provides no reliable advantage over simpler intrinsic cues. We will add this discussion to a new Appendix D.4 subsection, Analysis of the Feat Variant, while task-adaptive or jointly learned semantic scoring will be further explored in future work.
Q2: Dependency on an external feature extractor.
We appreciate the reviewer’s insightful comment. **Yes. Q2 uses frozen MedicalNet features, but MedicalNet is used only for the Q2 diagnostic and is not used by either VolumeProbe variant. VolumeProbe-Lite is fully volume-intrinsic, whereas VolumeProbe-Feat uses frozen 3DINO-ViT only for offline bank construction, which is included solely for diagnostic comparison.
Q3: Validation on additional types of scans.
Thank you for raising this important generality question.
References
[1] Wu L, et al. Voco: A simple-yet-effective volume contrastive learning framework for 3d medical image analysis. 2024.
[2] Pan T, et al. Structure-aware semantic discrepancy and consistency for 3d medical image self-supervised learning. 2025.
[3] Baid U, et al. The rsna-asnr-miccai brats 2021 benchmark on brain tumor segmentation and radiogenomic classification. 2021.