acceptodds
Published as a conference paper at NeurIPS 2026

MedCache: Training-Free Spatially Aware Caching for Accelerated Medical Video Generation

Ufaq Khan, Umair Nawaz, Sathira Silva, Numan Saeed, Muhammad U Sheikh, Muhammad Bilal, Junaid Qadir, Lena Maier-Hein, Yutong Xie, Muhammad Haris Khan

Abstract

Video world models are now being adapted to medical applications such as surgical simulation, procedural rehearsal, and synthetic data generation, but their inference cost remains a major obstacle to practical use. Training-free caching is attractive because it can be applied to existing checkpoints, yet current methods face a clear trade-off. Lightweight rules track only the average change in the video and treat all regions of the frame as equally important, which is a poor fit for medical video where the meaningful motion is often confined to a small region such as a tool tissue interaction. Richer rules recover spatial awareness by partially running the network on every step to inform the skip decision, but this decision cost is paid whether the step is skipped or not, and it eats into the speedup. We introduce MedCache, a training-free and probe-free cache for rectified-flow video generation. MedCache reads a spatial risk signal directly from the latent using cheap arithmetic, with no help from the network itself. It combines this risk signal with a prompt-derived domain prior and a lazy consistency check that runs only when reuse is no longer clearly safe. Across three open-world model families in Text2World and Image2World settings, MedCache improves both speed and quality over the strongest training free baselines in the medical regime it targets. On Cosmos-H-Surgical 2B Text2World, it raises Total quality from 0.767 to 0.837 over EasyCache while reducing latency from 185 seconds to 95 seconds. Ablations show that risk-weighted drift drives the runtime gain, while the prior and guard recover fidelity.

Keywords:
Sydney, Main Track

Reviews

Among:
Shape:
123456this paper, Bottom 49%
Figure 1. Mean review rating of the reviewed papers at NeurIPS 2026. This paper averages 4.33 over 3 reviews, above 49% of the others.
Reviewer_T1q5OpenReview ↗
Rating
4
Clarity
2
Confidence
3
Originality
3
Quality
3
Significance
3
Read review
Summary

The authors propose MedCache as a training-free and probe-free cache for medical video generation based on rectified-flow. MedCache combines a latent-derived spatial risk map with a prompt-derived domain prior and a lazy high-frequency consistency check to improve both the speed and quality of medical video generation. The proposed method was validated on Text2World and Image2World settings. The results show that it can outperform or be competitive with baseline methods for medical video generation in terms of video quality and generation speed.

Strengths and weaknesses

Strengths:

  1. The proposed method can build a spatially selective reuse rule for medical video generation, which is beneficial when the underlying dynamics are structured and spatially concentrated as in medical video.
  2. The proposed method can improve the speed and quality of medical video generation over baseline caching methods.

Weaknesses:

  1. The three complementary spatial energies, i.e., S, F, M, used for spatial risk estimation are heuristic. To me, it is confusing why these spatial energies can be combined (Eq. (7)) as a risk indicator. The authors should give some intuitive illustration on why these spatial energies can be combined (Eq. (7)) as a risk indicator.
  2. Are there any other spatial energies can be used as risk estimator?
  3. In Eq. (7), the three normalized spatial energies were linearly combined as a risk estimator. Will it be better to use a nonlinear function (e.g., Tanh or MLP) to map the spatial energies into a risk estimation?
  4. On broader generic checkpoints, e.g., WAN2.1, MedCache’s gain on video generation quality is quite limited.
Questions
  1. Why the three complementary spatial energies, i.e., S, F, M, can be combined (Eq. (7)) as a risk indicator?
  2. Are there any other spatial energies can be used as risk estimator?
  3. In Eq. (7), the three normalized spatial energies were linearly combined as a risk estimator. Will it be better to use a nonlinear function (e.g., Tanh or MLP) to map the spatial energies into a risk estimation?
Limitations
  1. The three complementary spatial energies, i.e., S, F, M, used for spatial risk estimation are heuristic. The authors should give some intuitive illustration on why these spatial energies can be combined (Eq. (7)) as a risk indicator.
  2. On broader generic checkpoints, e.g., WAN2.1, MedCache’s gain on video generation quality is quite limited.
Paper formatting concerns

None

Final justification

I thank the authors for the detailed rebuttal. They have partially addressed my concerns. So, I would like to raise my rating from 3 to 4.

1 comment

We thank Reviewer T1q5 for recognizing the value of spatially selective reuse and for asking us to explain the risk estimator more clearly. The submission states what the three energies measure, but does not sufficiently explain their complementarity or the intended interpretation of Eq. (7). We clarify this below, add controls using alternative spatial energies and fusion rules, and qualify the WAN2.1 results.

1. Why can SS, FF, and MM be combined?

The risk map in Eq. (7) is not a calibrated probability of clinical error or a semantic segmentation map. It has a narrower purpose: ranking spatial locations by the risk of applying a reused residual.

CueSignalReuse failure targetedMedical example
Structural energy SSFirst-order spatial gradientsDisplacement or blurring of persistent interfacesOrgan boundaries; tool-tissue contours
High-frequency energy FFLocal variation of the Laplacian responseLoss of thin or rapidly varying detail underrepresented by first-order edgesFine sutures; narrow interfaces; endoscopic texture
Relative-motion energy MMSelf-normalized change from the preceding same-branch latentLocal change within an otherwise stable sceneInstrument motion; tissue deformation; moving fluid

SS and FF describe the current spatial state at two derivative orders, while MM describes how that state changes. A static boundary may have high SS but low MM; fine texture may have high FF without a strong coarse edge; and a locally moving instrument may have high MM while most of the frame remains unchanged. Using only one cue can therefore miss failure modes represented by the others.

Each map is independently min-max normalized to [0,1][0,1]. Equation (7) consequently combines dimensionless spatial rankings rather than raw quantities with incompatible units. The non-negative sum acts as a union-of-evidence rule: any cue can raise a location's importance, the cues cannot cancel one another, and clipping limits extreme responses. We view this as a transparent training-free ranking rule, not the only possible construction.

The submitted Cosmos-H-Surgical Image2World ablation supports this interpretation:

Risk basisSpeedupSkip rateTotal
MM2.28×2.28\times61.4%61.4\%0.8400.840
SS2.23×2.23\times60.0%60.0\%0.8400.840
S+MS+M2.29×2.29\times60.0%60.0\%0.8410.841
S+F+MS+F+M2.24×2.24\times60.0%60.0\%0.8440.844

The similar skip rates show that the full basis is not included merely to increase reuse. Its benefit here is fidelity: S+F+MS+F+M recovers the uncached Total of 0.8440.844 while retaining 2.24×2.24\times acceleration.

We also evaluated all subsets of {S,F,M}\{S,F,M\}, including no spatial weighting, on a fixed 20-sample Cosmos-Predict-2.5 2B Text2World bank with all other settings frozen:

BasisSpeedupSkip rateTotal
None1.628×1.628\times41.43%41.43\%0.8556790.855679
SS1.605×1.605\times41.29%41.29\%0.8561450.856145
FF1.604×1.604\times41.29%41.29\%0.8560640.856064
MM1.593×1.593\times40.86%40.86\%0.8572660.857266
S+FS+F1.603×1.603\times41.29%41.29\%0.8563510.856351
S+MS+M1.597×1.597\times41.00%41.00\%0.8568310.856831
F+MF+M1.602×1.602\times41.14%41.14\%0.8563500.856350
S+F+MS+F+M1.619×1.619\times41.00%41.00\%0.8570070.857007

These variants span only 0.001590.00159 Total with closely matched skip rates, showing that the controller is not brittle to the exact cue subset. We therefore do not claim that every cue must yield a large independent gain on broad aggregate metrics: MM-only is nominally highest on this small bank, while the full basis is within 0.0002590.000259.

We repeated the key comparison on the full 200-prompt evaluation:

ScopeNNNo weightingMM onlyS+F+MS+F+MPaired Δ\Delta (full minus MM), 95%95\% CI
All prompts2002000.8626460.8626460.8626590.8626590.8627760.862776+0.000118+0.000118 [−0.000099,0.000344][-0.000099,0.000344]
Intervention86860.8570960.8570960.8568940.8568940.8572560.857256+0.000362+0.000362 [0.000035,0.000713][0.000035,0.000713]

The aggregate difference is small and its CI includes zero. On intervention prompts, however, the full basis improves over motion-only with a positive paired CI, consistent with structural and high-frequency cues mattering most when localized interfaces and fine procedural structure are important.

We will sharpen the claim accordingly: the three energies form an interpretable basis within one risk estimator, not three separate contributions that must each produce a large gain in every setting. Their clearest benefit appears in structured medical content; a simpler basis may suffice on broader aggregate metrics.

2. Can other spatial energies be used?

Yes. Sobel, Laplacian, and relative change are not uniquely optimal. Other inexpensive statistics, including local variance, wavelet energy, entropy, or orientation coherence, could provide similar spatial evidence. We selected the submitted operators because they are parameter-free, interpretable, inexpensive at latent resolution, and cover distinct failure modes.

To test dependence on the exact filters, we replaced SS and FF with parameter-free local variance while retaining MM; all other settings remained frozen:

BasisSpeedupSkip rateTotalPSNRSSIMAgreement
Submitted S+F+MS+F+M1.619×1.619\times41.0%41.0\%0.857010.8570124.151924.15190.866460.86646Reference
Local variance +M+M1.598×1.598\times41.0%41.0\%0.856880.8568824.177824.17780.866870.8668719/2019/20 videos byte-identical

The alternative changes Total by only −0.00013-0.00013, with paired 95%95\% CI [−0.00038,0.00000][-0.00038,0.00000], while retaining the same skip rate. This supports the design principle rather than filter uniqueness: what matters is a cheap, spatially resolved signal that reweights cache drift without probing the generator.

3. Would nonlinear fusion be better?

We tested two parameter-free nonlinear controls with all other settings fixed:

FusionSpeedupSkip rateTotalChange from linear
Linear S+F+MS+F+M1.619×1.619\times41.0%41.0\%0.857010.85701Reference
tanh⁡(S+F+M)\tanh(S+F+M)1.590×1.590\times40.7%40.7\%0.857430.85743+0.00042+0.00042; 95%95\% CI [−0.00086,0.00213][-0.00086,0.00213]
Pixelwise max⁡(S,F,M)\max(S,F,M)1.597×1.597\times41.0%41.0\%0.857010.85701Numerically unchanged; 20/2020/20 videos identical

Neither nonlinear rule yields a statistically resolved quality improvement or higher speed. We therefore retain linear non-negative fusion because it is transparent, inexpensive, and sufficient for spatial ranking.

An MLP might learn a more complex mapping, but it would require training data and a target definition for risk, add checkpoint-dependent parameters and inference overhead, and change the problem from training-free caching to a learned controller. We do not claim that an MLP can never help; it belongs to a different setting.

4. Interpreting WAN2.1

We agree that the quality gain on WAN2.1 is limited, as already noted in Supplement F:

WAN2.1 14B taskUncached TotalWorldCache speedup / TotalMedCache speedup / Total
Text2World0.9040.9041.18×/0.8981.18\times/0.8983.62×/0.8913.62\times/0.891
Image2World0.8850.8852.02×/0.8842.02\times/0.8843.77×/0.8833.77\times/0.883

These rows demonstrate transfer of the acceleration mechanism, not universal quality improvement. In Image2World, MedCache increases speedup from 2.02×2.02\times to 3.77×3.77\times with a 0.0010.001 Total reduction relative to WorldCache. In Text2World, it provides substantially greater speed with a 0.0070.007 reduction. We will state more prominently that the strongest speed-quality gains occur on the medical and image-conditioned Cosmos settings, while WAN2.1 represents a more aggressive operating point.

This does not imply failure on every generic checkpoint. On HunyuanVideo/VBench, MedCache reaches 3.44×3.44\times speedup and 0.8990.899 Total, versus 0.8960.896 uncached and 2.93×/0.8902.93\times/0.890 for WorldCache. We will use these results to distinguish broad applicability from the settings in which MedCache offers its clearest advantage, rather than claiming uniform dominance.

Reviewer_jVDuOpenReview ↗
Rating
4
Clarity
3
Confidence
4
Originality
2
Quality
3
Significance
3
Read review
Summary

Medcache is a training free diffusion caching method for speeding up rectified flow trained medical video generation models. The idea is that you can decide when to skip a denoising step (by reusing the cached residual) in a spatially aware way without probing the large network (probing means you don't run any parts of the heavy DiT to make the skip decision). The way they decide on when to skip is by reading a cheap risk map straight from the latent, like sobel edges, laplacian maps, or motion drift, and upweightig the drift in the regions that actually matter clinically. Their method sits in between easycache (fast but no spatial awareness) and worldcache (spatial awareness but probing is needed). Medcache yields around 2.8x speedup on Cosmos 2b while also improving the quality over the strongest training free baselines across a few open world model families.

Strengths and weaknesses

Overall Medcache is a good idea and I lean positive on it. My only hesitation is almost entirely about how many hyperparameters it has and whether the evaluation is broad enough to turst that those knobs are robust rather than fitting on the benchmark. I also have my worries, whenever a technical paper have so many knobs (like a knob fixing the effect of some other knob), it reminds me of an AI generated technique which is a bit repellant at this stage of research. That being said, the idea is still good and there is value in this work. I am open to moving up or down on my score depending on how the authors handle the hyperparameter robustness question.

Significance.\textbf{Significance.} The problem and the angle they are taking are significant, no question about it. Inference cost and latency is a real blocker for interactive and iterative medical video use, and training free caching is a great tool because it applies to ecxisting checkpoints without more training. The observation that you can get spatial when-to-cache awareness without probing the generator because the latent already carries the signal is great and they back it up with a cost model bound (Eq 2) showing why the per step probe cost in worldcache eats into the speedup. The significance somewhat narrowed by the method applied only in the medical domain though, but the method itself is not medical specific so I think the contribution is more general.

Originality.\textbf{Originality.} The probe free spatial design is the novel part and although it is incremental, it is still a fair contribution. The individual ingredients of their method (sobel, laplace, accumuated drift caching etc.) are all known and the accumulated error structure is borrowed directly from easycache. Still the framing is non obvious and useful so I think it is okay.

Quality.\textbf{Quality.} I have my concerns about the quality of this paper. Their method is essentially a stack of heuristics held together by a a lot of hand set parameters. Like the risk-weighting strength β=6.0\beta = 6.0, the risk map weights = {1, 0.75, 1.25}, the guard band kappa = 1.1 and eta = 0.2 the guard trigger rho > 1,5 and the top k = 12% support the warm up W0= 6, the domain scales being 0.7,0.95,1.5, the list goes on and on and on. From these parameters, it makes me think that this is an AI generated approach (I personally observed that especially claude makes so many hyperparameters for the methods it suggests), but I do not want to have that assumption here. The point is though, this is a lot of hyperparameters for a training free caching method and from what I see most of them are asserted rather than ablated. The paper does ablate the high level components like risk weighted drift drives speed, the prior and guard recovering fidelity etc., which looks good but a component ablation is not the same as showing the method is insensitive to these specific values. If these parameters were tuned per setting, then the reported pareto win could be partly a fitting artifact and I cannot tell from the current results if that is the case. Furthermore, the prompt derived domain prior seems a bit worrying which is literally keyword matching into three hardcoded categories, with three fixed scales. That feels weak as medical domain or a prompt phrasing that does not hit those keywords just falls back to sigma = 1 and gets none of the benefits and it is not clear this generalizes beyond the prompts they tested. The motivation in fig 2b (top 10% of the pixels cary most of the drift mass) looks strong but appears to be shown on a representative sample, so I would want to know this concentration holds in aggragate across domains since the entire premise of this idea stands on the drift being spatially concentrated. On the positive side, the results look encouraging and harder to fake than a single cherry picked row. Medcache shows a simultaneous speed and quality improvement over the other caching techniques more than one more family and not jsut in one favourable setting.

Clarify.\textbf{Clarify.} Paper is nicely written and understandable. It can be reproduced from what is given.

Questions
  1. Hyperparam sensitivity is my biggest concern as I said. For the main constants can you provide sensitivity curves showing the speed quality operating point is stable across reasonable ranges? And were any of these settings tuned per model or per setting, or is it a single fixed config across all of Table 1?
  2. The prompt derived domain prior is keyword matching into three categories with three fixed scales. How robust is this to prompts that do not include these keywords, or to medical domains not covered by your prompt set, like ultrasound or dermatology? Also, what fraction of your evaluation prompts actually resulted in a non-default sigma? It would be helpful to separate how much of the reported gain comes from the prior itself versus the risk map.
  3. Fig 2b motivates the whole method (top 10% pixels carry the most drift), but it looks like just one representative sample (please indicate if it is an aggregate already). Can you report this concentration in aggragate over the dataset and across the different model families so. the central premise is demonstrated fully?
  4. The risk map is refreshed only on conditional cache failure and reused across subsequent skips. How stale can this map get during a long skip streak and is there a failure mode where the risk map points at the wrong region because it was computed many passes ago? Or medical domain is stationary enough that it never happens?
Limitations

The paper relies on farily large set of hand set hyperparameters and their robustness across domains and models is not established, which is a real concern for a training free method that is supposed to drop into arbitrary checkpoins. Also the domain prior is hardcoded keyword matching into multiple categories which is unlikely to generalize to medical domains or prompt phrasings outside the tested set, and this is presented as a feature without acknowledging the fragility. The evaluation, while spanning a few model families, is still relatively narrow in terms of medical domains and prompt diversity, so the claim that medcache helps "the medical regime it targets" is somewhat broader than what is demonstrated.

Paper formatting concerns

N/A

Final justification

The rebuttal and discussion addressed my main concerns, and I am updating my rating to Borderline Accept. In more detail:

  • Hyperparameter robustness: My primary concern was that the large number of hard set constants could make the reported tradeoff problematic. The authors clarified that the controller parameters were selected once on a disjoint development split and then frozen across models and tasks which makes sense. More importantly, the additional one dimensional sensitivity sweeps, joint perturbation study over multiple constants, and seed analysis provide convincing evidence that the method is not dependent on a overly tuned configuration so I consider this concern largely resolved.

  • Prompt prior and medical motivation: The authors clarified that the prompt-agnostic risk weighted controller is the core method, while the keyword prior only provides a smaller optional operating point adjustment. This is a more convincing framing, and I agree that the prior should be presented this way in the revision. The additional dataset-level spatial-concentration analysis and localized instrument/boundary fidelity results also provide substantially stronger evidence for the motivating medical regime, where small spatial regions can be disproportionately important.

  • Risk-map validity/staleness: The aggregate risk-map analysis and refresh-delay experiments address my questions about whether the spatial concentration is representative and whether stale risk maps can destabilize the method. I find these results sufficient for the claims made in the paper.

  • Corrected component ablation: I initially remained concerned by the apparent reversal between the submitted Table 3 and the rebuttal. The authors clarified that this resulted from interchanged efficiency entries for two configurations and an incorrect parameter label, rather than an implementation or evaluation change, and provided an independent sanity check consistent with the corrected interpretation.

Some limitations remain: the method is still based on a number of heuristic design choices, the prompt prior is unlikely to generalize to arbitrary medical domains and prompt formulations, and the medical-domain evaluation is not exhaustive. However, after the rebuttal I no longer think these concerns outweigh the paper's strengths. The core probe free spatial caching idea is useful, the empirical speed/quality gains are meaningful, and the additional evidence substantially improves my confidence that the results are not an artifact of hyperparameter tuning. I therefore lean toward acceptance.

1 comment

We thank the reviewer jVDu for recognizing the significance of inference latency, the novelty of obtaining spatial reuse information directly from the latent without probing the generator, and the consistency of the results across multiple model families. The questions on parameter robustness, the prompt prior, Figure 2b, and risk-map staleness help us clarify the method and add more targeted evidence.

Q1. Hyperparameter sensitivity and selection

The number of constants listed in the paper may suggest extensive per-setting tuning, but this was not our protocol. As stated in Supplement A.6, all MedCache parameters were selected once on a disjoint Text2World development split, frozen, and transferred unchanged across models and tasks; Image2World used the Text2World-selected controller without retuning. Denoising steps, CFG scale, and resolution are backbone sampling settings, not MedCache parameters. The prompt prior is also a fixed lookup rule and is never selected from evaluation quality or latency.

The constants have distinct roles: τ=0.095\tau=0.095 is the main reuse-tolerance control; κ=1.10\kappa=1.10 sets the forced-recompute boundary; η=0.20\eta=0.20 defines the clearly safe band; (αS,αF,αM)=(1,0.75,1.25)(\alpha_S,\alpha_F,\alpha_M)=(1,0.75,1.25) and β=6\beta=6 define how spatial risk redistributes drift rather than prescribing a skip budget; and σ\sigma is an optional context-dependent scale. Thus, these are not twelve co-equal speed-quality knobs.

Supplement D.4/Figs. 10-11 already sweep τ,β,κ\tau,\beta,\kappa on WAN2.1 14B Image2World. We additionally repeated these sweeps and tested all exposed constants on a fixed, domain-balanced 20-prompt Cosmos-Predict-2.5 2B Text2World bank not used for configuration selection. Prompts, seeds, 35-step schedule, resolution, hardware, and all non-swept settings were fixed. The frozen configuration achieves 2.619×2.619\times speedup [2.502,2.755][2.502,2.755] and Total 0.85700.8570 [0.8421,0.8711][0.8421,0.8711].

SweepRangeReuseSpeedupTotalPSNR/SSIM trend
τ\tau0.075→0.1150.075\rightarrow0.11531.1431.14%\rightarrow46.43%2.408→2.762×2.408\rightarrow2.762\times0.85480.8548-0.85920.859226.724/0.9082→22.366/0.831826.724/0.9082\rightarrow22.366/0.8318
κ\kappa1.00→1.201.00\rightarrow1.2034.4334.43%\rightarrow46.43%2.472→2.766×2.472\rightarrow2.766\times0.85390.8539-0.86160.861625.657/0.8894→22.873/0.839325.657/0.8894\rightarrow22.873/0.8393
β\beta0→90\rightarrow941.4341.43%\rightarrow41.00%2.628→2.618×2.628\rightarrow2.618\times0.85570.8557-0.85700.8570essentially flat

Increasing τ\tau or κ\kappa smoothly increases reuse and speed while paired PSNR/SSIM to the same-seed uncached output decrease, as expected. Total remains within a narrow perceptual-quality band. The β\beta response is nearly flat: reuse changes by only 0.430.43 percentage points and the largest Total change from the frozen setting is 0.00130.0013, showing that β=6\beta=6 is not sharply tuned. τ\tau and κ\kappa both act on the same effective reuse boundary rather than serving as unrelated corrective mechanisms.

To test interactions, we used an eight-run L8L_8 design varying seven constants simultaneously: τ∈0.0855,0.1045\tau\in{0.0855,0.1045}, β∈4.5,7.5\beta\in{4.5,7.5}, κ∈1.05,1.15\kappa\in{1.05,1.15}, η∈0.15,0.25\eta\in{0.15,0.25}, topk {9%,15%}, ρ∈1.35,1.65\rho\in{1.35,1.65}, and Wo∈5,7Wo\in{5,7}. Across these runs, speedup spans 2.4522.452-2.798×2.798\times, Total 0.85070.8507-0.86000.8600, and no interaction collapse occurs. Across the complete 40-configuration study, including Q2 prior contrasts, every configuration retains at least 2.4×2.4\times speedup; 38/4038/40 are within 0.0050.005 Total of the frozen setting and 40/4040/40 within 0.010.01. Seeds 1,7,421,7,42 on the same six contexts give 1.783,1.774,1.789×1.783,1.774,1.789\times speedup and 46.1946.19%,45.24%,45.71% reuse. We will revise the presentation to distinguish the low-dimensional reuse boundary from stable spatial coefficients and optional safety settings.

Q2. Prompt-derived prior

Keyword matching is the least general component and is not the basis of the spatial or medical-motivation claim. Supplement F already identifies it as hand-specified and potentially fragile to unseen prompt styles. Its only role is τeff(p)=σ(p)τ\tau_{\mathrm{eff}}(p)=\sigma(p)\tau; it does not enter the risk map, risk-weighted drift, or guard. If no keyword matches, σ=1\sigma=1 and MedCache becomes the complete prompt-agnostic controller.

We re-audited exactly the submitted three groups and fixed vocabulary:

Prompt bankNon-neutral / total
Medical Text2World171/200171/200 (85.585.5%)
Medical Image2World23/2323/23 (100100%)
CholecT50 surgical Image2World300/300300/300 (100100%)
Generic controls0/160/16 (00%)

The 16 generic prompts cover animals, architecture, food, people, lifestyle, plants, scenery, and vehicles. Ultrasound, dermatology, and dermoscopy examples not represented in the submitted vocabulary correctly fall back to σ=1\sigma=1; we therefore do not claim semantic generalization to arbitrary specialties.

The corrected component ablation separates the prior from the core: EasyCache gives 1.39×1.39\times/Total 0.8400.840; prompt-agnostic risk-weighted drift gives 2.37×2.37\times, 61.161.1% reuse/Total 0.8400.840; adding the prior gives 2.52×2.52\times, 64.064.0%/Total 0.8400.840. Thus, the spatial cache provides the main gain, while the prior is a smaller optional operating-point adjustment. We will state this hierarchy explicitly.

Q3. Aggregate evidence behind Figure 2b

Figure 2b shows one representative decision; we will label it accordingly. For dataset-level analysis, at each eligible conditional decision we select the highest-risk locations and measure the actual latent-drift mass inside them, averaging decisions within videos and then videos. CIs use 20,000 video-bootstrap replicates.

Checkpoint/taskEvaluationTop-1010% drift mass
Cosmos-Predict-2.5 2B T2W20 videos25.8325.83% [25.65,26.04][25.65,26.04]
Cosmos-H-Surgical 2B I2W300 videos/8,100 decisions27.1227.12% [26.99,27.25][26.99,27.25]

On the full 300-video I2W set, selected supports of 11%,5%,10%,12% contain 6.286.28%,14.21%,27.12%,32.42% drift, respectively, compared with uniform expectations of 11%,5%,10%,12%. Thus, the map consistently ranks locations carrying disproportionate latent change across both general and medical checkpoints.

The medical motivation is not that a small region must contain most frame-wide drift, but that cache-error consequences are spatially asymmetric. On 260 CholecT50 I2W cases, the fixed conditioning-frame instrument region occupies only 7.427.42% of the image. Against same-seed uncached generation over the first generated second, WorldCache versus MedCache MAE is 32.53432.534 versus 13.69913.699 in the instrument region, a 57.957.9% reduction with absolute reduction 18.83518.835 [17.247,20.540][17.247,20.540], and 31.00531.005 versus 13.72313.723 at its boundary, a 55.755.7% reduction with absolute reduction 17.28317.283 [15.954,18.671][15.954,18.671]. This is a localized cache-fidelity diagnostic, not a claim of segmentation or clinical correctness.

Q4. Risk-map staleness

MedCache does not assume stationarity. The map is refreshed after every rejected conditional reuse/full computation and reused only during the following skip streak. For analysis only, we computed a fresh map at every eligible decision and compared it with the cached map; this diagnostic did not affect generation or latency. Map age counts conditional decisions since refresh.

Checkpoint/taskDecisionsMean/95th/max ageMap cosineTop-1212% IoU
Cosmos-Predict-2.5 2B T2W5402.08/5/112.08/5/110.97240.9724 [0.9700,0.9747][0.9700,0.9747]0.56770.5677 [0.5476,0.5882][0.5476,0.5882]
Cosmos-H-Surgical 2B I2W8,1003.22/8/163.22/8/160.99060.9906 [0.9904,0.9909][0.9904,0.9909]0.71070.7107 [0.7056,0.7159][0.7056,0.7159]

The soft map remains highly similar; lower IoU shows that locations near the top-1212% boundary can change, which we will state explicitly. In a controlled refresh-delay stress test on the 20-video T2W bank, N=1,2,4N=1,2,4 give mean/95th/max ages 2.08/5/112.08/5/11, 3.16/8/143.16/8/14, and 5.07/12/205.07/12/20; cosine 0.9724,0.9688,0.95870.9724,0.9688,0.9587; IoU 0.5677,0.5242,0.45930.5677,0.5242,0.4593; and Total 0.857007,0.857007,0.8568310.857007,0.857007,0.856831. Even N=4N=4 changes Total by less than 0.00020.0002; we retain conservative N=1N=1.

Finally, the soft multiplier (1+βr)(1+\beta r) gives every location base weight 11, so a newly changing region outside the old high-risk support still contributes to accumulated drift. When reuse is rejected, a full computation refreshes the map. This explains why exact support may evolve without destabilizing output quality.

Reviewer_eDhAOpenReview ↗
Rating
5
Clarity
4
Confidence
2
Originality
3
Quality
3
Significance
3
Read review
Summary

MedCache is a training-free caching mechanism for medical video generation that improves speed-quality trade-offs in rectified-flow models. It uses three lightweight components: (1) a spatial risk map derived from latents to identify regions where reuse errors matter most, (2) a prompt-derived domain prior that adjusts skip aggressiveness for medical contexts, and (3) a lazy Laplacian consistency check for safety verification. The key insight is that latent representations already contain sufficient spatial information to guide selective reuse decisions without expensive network probing. The method is evaluated across four world-model families in both text-to-world and image-to-world settings.

Strengths and weaknesses

Strengths

The key insight is compelling: latent representations already contain sufficient spatial information to guide selective reuse decisions without expensive network probing. Clean delivery and well-motivated design choices. Each component has a clear role in the speed-quality trade-off.

Weaknesses

Table 1 inconsistencies: Several bolded/underlined numbers show mismatches (e.g., IQ Large-scale models column where Easy Cache, FasterCache, and WorldCache perform identically). The baseline should be more prominently emphasized for clarity. Weak ablations: The ablation study weakens the contribution claims: D has minimal effect on IQ, with slight improvements. C reduces speedup without improving quality over the B variant. Unclear component necessity: The ablation results suggest not all three proposed components meaningfully contribute to the final method, raising questions about design complexity.

Questions

While the design choices are well justified, the ablations do not fully support the contribution of individual components. How is the loss of speedup justified by marginal quality improvements? Would a simpler two-component design be preferable?

Limitations

Limitations are not discussed.

Paper formatting concerns

No

Final justification

The authors addressed the weaknesses, however, the final version should be revised.

1 comment

We thank Reviewer eDhA for the positive assessment of the central idea, particularly the observation that latent representations can provide spatial information for cache decisions without requiring an expensive model-side probe. We also appreciate the reviewer’s comments on the clarity of the presentation and the distinct intended roles of the method’s components.

The concerns regarding Table 1 formatting and the necessity of each component are well taken. They prompted us to recheck the final experiment records and identify presentation and transcription errors that obscured the intended interpretation of the ablation results.

1. Table 1 formatting and the uncached reference

The inconsistent bold and underline markers in Table 1 were formatting errors. We have corrected them and will use the following convention consistently in the revision:

  • The uncached model is displayed separately as the quality reference.
  • Best and second-best rankings are computed only among accelerated methods.
  • Tied values receive the same formatting.

We will also state this convention more prominently in the caption so that the uncached reference is not confused with the ranking among acceleration methods.

2. Component necessity and the speed-quality trade-off

We thank the reviewer for directing our attention to Table 3. While checking the final experiment records, we identified two transcription errors in the submitted table:

  1. The efficiency values for configurations B and C were interchanged.
  2. The intervention scale in row C was written as (\sigma=0.70) instead of the intended (\sigma=1.25).

The corrected table is:

ConfigurationSpeedupSkip rateIQTotalIntended role
Uncached reference1.00x--0.6100.844Quality reference
A: EasyCache1.39x--0.5940.840Scalar-cache starting point
B: + risk-weighted drift, σ\sigma=12.37x61.1%0.5930.840Core spatial cache
C: + intervention prior, σ\sigma=1.252.52x64.0%0.5930.840Threshold adjustment
D: + lazy consistency guard2.52x64.0%0.6120.846Fidelity recovery

To independently verify the effect of the threshold scale, we also reran a fixed set of ten separate Cosmos-H-Surgical 2B Image2World samples. We held the model, inputs, denoising schedule, cache configuration, hardware, and all other parameters fixed. We varied only (\sigma) and disabled the guard so that its effect would not be conflated with the threshold change.

σ\sigmaLatency per sample, 95% CISpeedupSkip rateTotal
No cache52.4 s [51.9, 53.1]1.000x0.00%0.8517
0.7026.0 s [24.8, 27.0]2.015x54.86%0.8473
1.0022.4 s [21.6, 23.3]2.339x62.29%0.8454
1.2521.0 s [20.2, 21.9]2.495x65.43%0.8499
1.7019.3 s [18.8, 20.0]2.715x68.86%0.8459

This additional experiment is a post-submission sanity check rather than a replacement for the submitted ablation. Nevertheless, it reproduces almost the same relative efficiency change as the corrected Table 3.

Increasing σ\sigma from 1.00 to 1.25 improves speedup by 6.7%, from 2.339x to 2.495x. This closely matches the 6.3% improvement in the corrected Table 3, from 2.37x to 2.52x. Increasing σ\sigma further to 1.70 produces greater acceleration, but with a lower Total score. This supports σ\sigma=1.25 as the intended balanced operating point rather than the most aggressive setting.

With the corrected ordering, the contribution of each component is clearer:

  • A to B isolates the core contribution. Replacing global scalar drift with risk-weighted spatial drift increases speedup from 1.39x to 2.37x while preserving Total at 0.840.

  • B to C adjusts the operating point. The prompt prior is not intended to provide an independent quality gain. It increases the skip rate from 61.1% to 64.0% and speedup from 2.37x to 2.52x while maintaining the same Total.

  • C to D isolates the guard. The guard is intended as a fidelity safeguard rather than an additional acceleration mechanism. At the same 2.52x speedup and 64.0% skip rate, it improves IQ from 0.593 to 0.612.

The guard therefore closes the full 0.017 IQ deficit between configuration C and the uncached reference of 0.610. We interpret the remaining (+0.002) difference as numerical parity, not as evidence that caching improves the underlying generator. The corresponding increase in Total is smaller, from 0.840 to 0.846, because Total is the arithmetic mean of four metrics. An IQ improvement of 0.019 contributes only [0.019/4 = 0.00475] to the composite score if the other dimensions remain approximately unchanged. Thus, configuration D represents a fixed-efficiency fidelity improvement over C, while configuration C provides the additional throughput gain.

Our original presentation made the method appear more complex than necessary. We will revise the paper to state the contribution hierarchy more clearly:

  • Risk-weighted spatial caching is the core method.
  • The prompt prior is an operating-point control.
  • The lazy guard is a fidelity safeguard near the reuse boundary.

Comments on the paper

1 comment
Meta-review

The paper presents a training-free approach for speeding up medical video generation by leveraging the latent space and image processing operators. The paper received an initial review of 3,3,4. The reviewers generally appreciated the idea of skipping inference steps using latents themselves, leading to substantial improvement in speed and quality. However, the reviewers still have many questions and concerns that the authors should address during the rebuttal.

The AC notes the primary concerns that came out of this discussion: (1) The proposed method seems to be very general, so why is the paper focused on medical video generation? What is specific about the technique that is related to medical video? (2) There are significant concerns about the large number of hyperparameters and heuristics-based design choices in the approach, and no systematic study indicating how robust and important these choices and settings are, raising concerns of a potential AI-generated method. Authors are strongly encouraged to read and respond to R-jVDu’s (Q 1-4), R-T1q5’s (Q 1), and R-eDhA’s concerns about the lack of many ablation studies.

Overall, the AC feels the current version of the paper has a large number of hyperparameter and heuristic-driven design choices, which have neither been conceptually explained nor empirically validated, and lacks a concrete connection to the medical domain. The rebuttal should try to address these critical concerns.

After the rebuttal, the score of the paper is 4,4,5. The rebuttal mostly addressed the 2 main concerns regarding the scope of the paper (Why medical videos) and the heuristic-driven design choices and their robustness. The AC recommends the paper for acceptance. However, the AC notes that the paper requires significant revisions, primarily to motivate the medical focus better and clarify the design choices. The supplementary material should include more robustness analysis and additional experiments presented in the rebuttal. The AC would also ask the authors to maintain brevity in any additional experiments included in the paper/supplementary. The rebuttal was particularly long and verbose which could have been more succint.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Related papers

Loading the map…

Discussion (0)

Sign in to comment.