- Rating
- 4
- Clarity
- 2
- Confidence
- 3
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
The authors propose MedCache as a training-free and probe-free cache for medical video generation based on rectified-flow. MedCache combines a latent-derived spatial risk map with a prompt-derived domain prior and a lazy high-frequency consistency check to improve both the speed and quality of medical video generation. The proposed method was validated on Text2World and Image2World settings. The results show that it can outperform or be competitive with baseline methods for medical video generation in terms of video quality and generation speed.
Strengths and weaknesses
Strengths:
- The proposed method can build a spatially selective reuse rule for medical video generation, which is beneficial when the underlying dynamics are structured and spatially concentrated as in medical video.
- The proposed method can improve the speed and quality of medical video generation over baseline caching methods.
Weaknesses:
- The three complementary spatial energies, i.e., S, F, M, used for spatial risk estimation are heuristic. To me, it is confusing why these spatial energies can be combined (Eq. (7)) as a risk indicator. The authors should give some intuitive illustration on why these spatial energies can be combined (Eq. (7)) as a risk indicator.
- Are there any other spatial energies can be used as risk estimator?
- In Eq. (7), the three normalized spatial energies were linearly combined as a risk estimator. Will it be better to use a nonlinear function (e.g., Tanh or MLP) to map the spatial energies into a risk estimation?
- On broader generic checkpoints, e.g., WAN2.1, MedCache’s gain on video generation quality is quite limited.
Questions
- Why the three complementary spatial energies, i.e., S, F, M, can be combined (Eq. (7)) as a risk indicator?
- Are there any other spatial energies can be used as risk estimator?
- In Eq. (7), the three normalized spatial energies were linearly combined as a risk estimator. Will it be better to use a nonlinear function (e.g., Tanh or MLP) to map the spatial energies into a risk estimation?
Limitations
- The three complementary spatial energies, i.e., S, F, M, used for spatial risk estimation are heuristic. The authors should give some intuitive illustration on why these spatial energies can be combined (Eq. (7)) as a risk indicator.
- On broader generic checkpoints, e.g., WAN2.1, MedCache’s gain on video generation quality is quite limited.
Paper formatting concerns
None
Final justification
I thank the authors for the detailed rebuttal. They have partially addressed my concerns. So, I would like to raise my rating from 3 to 4.
We thank Reviewer T1q5 for recognizing the value of spatially selective reuse and for asking us to explain the risk estimator more clearly. The submission states what the three energies measure, but does not sufficiently explain their complementarity or the intended interpretation of Eq. (7). We clarify this below, add controls using alternative spatial energies and fusion rules, and qualify the WAN2.1 results.
1. Why can S, F, and M be combined?
The risk map in Eq. (7) is not a calibrated probability of clinical error or a semantic segmentation map. It has a narrower purpose: ranking spatial locations by the risk of applying a reused residual.
S and F describe the current spatial state at two derivative orders, while M describes how that state changes. A static boundary may have high S but low M; fine texture may have high F without a strong coarse edge; and a locally moving instrument may have high M while most of the frame remains unchanged. Using only one cue can therefore miss failure modes represented by the others.
Each map is independently min-max normalized to [0,1]. Equation (7) consequently combines dimensionless spatial rankings rather than raw quantities with incompatible units. The non-negative sum acts as a union-of-evidence rule: any cue can raise a location's importance, the cues cannot cancel one another, and clipping limits extreme responses. We view this as a transparent training-free ranking rule, not the only possible construction.
The submitted Cosmos-H-Surgical Image2World ablation supports this interpretation:
The similar skip rates show that the full basis is not included merely to increase reuse. Its benefit here is fidelity: S+F+M recovers the uncached Total of 0.844 while retaining 2.24× acceleration.
We also evaluated all subsets of {S,F,M}, including no spatial weighting, on a fixed 20-sample Cosmos-Predict-2.5 2B Text2World bank with all other settings frozen:
These variants span only 0.00159 Total with closely matched skip rates, showing that the controller is not brittle to the exact cue subset. We therefore do not claim that every cue must yield a large independent gain on broad aggregate metrics: M-only is nominally highest on this small bank, while the full basis is within 0.000259.
We repeated the key comparison on the full 200-prompt evaluation:
The aggregate difference is small and its CI includes zero. On intervention prompts, however, the full basis improves over motion-only with a positive paired CI, consistent with structural and high-frequency cues mattering most when localized interfaces and fine procedural structure are important.
We will sharpen the claim accordingly: the three energies form an interpretable basis within one risk estimator, not three separate contributions that must each produce a large gain in every setting. Their clearest benefit appears in structured medical content; a simpler basis may suffice on broader aggregate metrics.
2. Can other spatial energies be used?
Yes. Sobel, Laplacian, and relative change are not uniquely optimal. Other inexpensive statistics, including local variance, wavelet energy, entropy, or orientation coherence, could provide similar spatial evidence. We selected the submitted operators because they are parameter-free, interpretable, inexpensive at latent resolution, and cover distinct failure modes.
To test dependence on the exact filters, we replaced S and F with parameter-free local variance while retaining M; all other settings remained frozen:
The alternative changes Total by only −0.00013, with paired 95% CI [−0.00038,0.00000], while retaining the same skip rate. This supports the design principle rather than filter uniqueness: what matters is a cheap, spatially resolved signal that reweights cache drift without probing the generator.
3. Would nonlinear fusion be better?
We tested two parameter-free nonlinear controls with all other settings fixed:
Neither nonlinear rule yields a statistically resolved quality improvement or higher speed. We therefore retain linear non-negative fusion because it is transparent, inexpensive, and sufficient for spatial ranking.
An MLP might learn a more complex mapping, but it would require training data and a target definition for risk, add checkpoint-dependent parameters and inference overhead, and change the problem from training-free caching to a learned controller. We do not claim that an MLP can never help; it belongs to a different setting.
4. Interpreting WAN2.1
We agree that the quality gain on WAN2.1 is limited, as already noted in Supplement F:
These rows demonstrate transfer of the acceleration mechanism, not universal quality improvement. In Image2World, MedCache increases speedup from 2.02× to 3.77× with a 0.001 Total reduction relative to WorldCache. In Text2World, it provides substantially greater speed with a 0.007 reduction. We will state more prominently that the strongest speed-quality gains occur on the medical and image-conditioned Cosmos settings, while WAN2.1 represents a more aggressive operating point.
This does not imply failure on every generic checkpoint. On HunyuanVideo/VBench, MedCache reaches 3.44× speedup and 0.899 Total, versus 0.896 uncached and 2.93×/0.890 for WorldCache. We will use these results to distinguish broad applicability from the settings in which MedCache offers its clearest advantage, rather than claiming uniform dominance.