- Rating
- 4
- Clarity
- 3
- Confidence
- 3
- Originality
- 3
- Quality
- 3
- Significance
- 2
Read review
Summary
The paper looks at CLIP-style pre-training, focusing on Chest X-rays and radiology reports. Specifically, it focuses on the impact of semantically similar training samples being treated as negatives by the contrastive loss. The paper identifies two failure modes that are induced by this dynamic: a rise-then-fall behaviour in zero-shot classification performance as the number of training steps increases, and large batch collapse, where sufficiently large batch sizes prohibit generalization. The authors make a theoretical argument that these behaviours can be attributed to a target misspecification as opposed to standard overfitting. They verify this with experiments on MIMIC-CXR as well as on CLEVR-Radiology, a novel controlled testbed. These results motivate their new pre-training objective, CorLIP, which does not treat semantically compatible images and texts from distinct samples as negatives. Finally, the authors include experiments where the proposed method outperforms Vanilla CLIP as well as related prior work on a collection of classification benchmarks.
Strengths and weaknesses
Strengths:
-
The problem is well motivated, as semantically similar pairs being treated as negatives is something that has been observed previously in Chest X-ray CLIP training, forcing adopters to limit the batch size.
-
The theory nicely quantifies why the Vanilla CLIP objective will limit cosine similarity between semantically similar samples. The paper shows that this is due to a misaligned target rather than general overfitting.
-
The construction of a testbed, CLEVR-Radiology, to test these training dynamics in a more controlled environment, seems like it could be genuinely useful for the community.
Weaknesses:
The importance of the relationship between the comparability schema and the downstream classification task is understated. My main concern has to do with the implicit assumptions we make when we choose the compatibility kernel. Essentially, the choice of this kernel determines how we cluster images in representation space (by avoiding pushing compatible images and texts apart). The implication is that for strong zero-shot performance we should choose a kernel that aligns well with the downstream classification task. The paper acknowledges this somewhat by discussing how different granularities can be useful for different tasks, but I think this goes beyond that. It seems to me that CorLIP approaches supervised clustering (with labels extracted from reports), while maintaining the textual semantics (allowing for zero-shot classification), which could potentially be useful in certain settings. My worry, however, is that this method optimizes for zero-shot classification on specific tasks, which could come at the cost of generality, since much work in this domain evaluates representations on additional tasks such as facilitating better supervised learning, segmentation, and modality transfer [1, 2].
For example, we only see CorLIP outperforming prior work on MIMIC-CXR when using ChexBert-13d (which aligns nearly one-to-one with the MIMIC labels) to extract compatibility scores. On VinDr, the best configuration switches to the finer MedGemma-30d schema, not because it matches VinDr's labels (it does not), but because its finer granularity avoids collapsing distinctions that the coarse schema merges. That the optimal schema changes with the evaluation is the concern: schema choice is doing task-specific work.
Clarity of experiments. Secondly, I think the paper would benefit from clarity on several points.
- Due to the concerns discussed above, I think it would be fair to include the label spaces of all datasets that the paper evaluates on. Furthermore, while the latent fact states are included in the appendix, clustering will also be determined by the prompt given to MedGemma-30d, so this should likely be included as well.
- I think the paper would benefit from being more precise about the exact classification and projection heads used. Are these both linear layers, or are any of them MLPs? And perhaps more importantly, are the backbones completely fine-tuned in all experiments, or are any parts frozen? This is important for the discussion of the different behaviours observed in Section 2 to ensure that both the supervised and CLIP models are equally expressive (which would have an impact on generic overfitting).
- On a similar note, is the text projection / backbone fine-tuned as well?
Minor comments:
- Line 282 says that Figure 3 shows Vanilla CLIP evaluation, but I can't seem to find it.
- The "Data scaling helps more when it scales the right target." paragraph (line 292) only references results in the appendix, somewhat detracting from the flow of the paper.
- Since CorLIP essentially allows for clustering of semantically similar samples, it could be good to include some visualizations of this.
References:
[1] Zhou et al., (2026). A multimodal vision–language model for generalizable annotation-free pathology localization. Nature Biomedical Engineering, 1-15.
[2] Huang et al., (2021). Gloria: A multimodal global-local representation learning framework for label-efficient medical image recognition. In Proceedings of the IEEE/CVF international conference on computer vision (pp. 3942-3951).
Questions
- Have the authors thought about comparing these results against text-supervised clustering? I.e., extract clusters from the reports but don't align with them, and instead apply supervised contrastive learning between images [3]. This would, of course, forfeit open-vocabulary zero-shot inference, so it is not a drop-in replacement, but it could be worth comparing the representations extracted from both. Is there a reason to believe this would perform worse? The similarity between CorLIP and this setup is alluded to in Appendix A.4.
- Could the authors please clarify the experimental details asked about above?
- If I understand correctly, all of the values in the decomposition in Lemma 1 are realizable during training (, , ). Do the authors think it would be useful to include a plot of these values?
[3] Khosla et al., (2020). Supervised contrastive learning. Advances in neural information processing systems, 33, 18661-18673.
Limitations
Unfortunately, I find the scope of the work to be quite limited. As discussed above, my understanding is that the paper essentially optimizes for zero-shot classification, and even then, there is a need to choose an appropriate schema for the downstream classification task. The benefit of this method could be strengthened by comparing against standard supervised clustering (where the clusters have been extracted from the texts).
Paper formatting concerns
None
Final justification
My original review raised concerns regarding
- the clarity of some experimental details,
- the scope of the paper, and the potential overlap with classic supervised contrastive learning,
- the understated importance of the choice of comparability schema.
The author's rebuttal addressed many of these concerns by including the requested experimental details and a thorough discussion positioning the paper in relation to standard supervised contrastive learning, including additional experiments comparing against the SupCon baseline.
Some concerns remained, namely:
- The impact of the choice of compatibility schema is still not completely understood, and the fact that MedGemma-30d beats CheXbert-13d on CheXpert (even though the label spaces of the latter should align perfectly) means that it could be difficult to construct these schemas using expert knowledge.
- Whether or not CorLIP could lead to worse performance on alternative downstream tasks (e.g., report generation or supervised fine-tuning) remained underexplored since the paper mainly evaluates on zero-shot classification.
Still, after discussion with the authors, I believe the current contribution is acceptable as is, given that these limitations are properly raised in the final version of the manuscript.
We thank the reviewer for the careful reading, and are glad the review finds the problem well motivated, agrees the theory correctly attributes the failure to target misalignment rather than overfitting, and sees CLEVR-Radiology as useful to the community. We clarify each concern below.
1. Scope and positioning.
We respectfully clarify that our contribution is not an optimization for zero-shot classification, in two respects.
Why this problem matters. Radiology data is generated with paired images and reports in routine clinical care, making image–text contrastive learning one of the most widely adopted approaches for radiology representation learning. Major works across X-ray [2–7], CT [8, 9], and MRI [10] all build on the CLIP-style contrastive recipe. Yet practitioners routinely encounter unexplained failures, such as performance degradation during training and instability at larger batch sizes, and prior work has responded with heuristic fixes without a unified diagnosis. Our paper fills this gap: it identifies the structural root cause, explains both failure modes from a single mechanism, and derives a minimal correction. The scope is the contrastive learning objective and radiology data pretraining, not a single downstream task.
What we evaluate, and why. Zero-shot classification is one probe here, not the objective being optimized. Our evaluation answers the two questions central to a pretraining objective. (i) Representation quality. In-domain classification (Table 1), OOD classification on two external label spaces (Table 2), and dense phrase grounding on MS-CXR (Table 2), which is localization rather than classification. (ii) Scaling stability. Trajectory stability from B=16 to B=2048 (Figures 1, 3, 4), data scaling (Table 3), generality across loss families (CLIP and SigLIP, Figure 8), and transfer to another modality and encoder family (CXR to 3D CT, Section 5). This is what the heuristic fixes leave unresolved, and what matters most for pretraining at scale.
2. Comparison Against Supervised Learning
We group these concepts, since the distinction from each defines CorLIP's position.
Multi-label supervised learning is already our baseline. Training the vision encoder directly on report-extracted labels is the red dashed curve in Figures 1 and 3, using the CheXpert 14-class labels released with MIMIC-CXR, themselves derived from the reports, on the same backbone, data, augmentations, and schedule (Appendix E.1, L972-977). This is precisely "clusters extracted from the texts." Vanilla CLIP peaks well below it (0.68 vs 0.748), while sentence-level CorLIP exceeds it. The comparison is informative in one direction: label supervision cannot perform open-vocabulary or zero-shot inference at all, so exceeding it while retaining cross-modal alignment shows contrastive learning recovers its advantage once positives are correctly defined.
Supervised contrastive learning. In SupCon [41], the label set exhaustively defines the semantic space: samples sharing a label are positives, all others negatives, and no distinction outside the label list can be learned. A multi-label extension is still bounded by that predefined space. CorLIP is related to a multi-label, cross-modal variant of SupCon but is not reducible to it. Within the schema's coverage, extracted facts identify which off-diagonal cells are false negatives and correct the target. Outside the coverage, standard CLIP mechanics operate unchanged, and the text encoder still trains end-to-end on all textual content. The schema denoises the target rather than bounding what the model can represent, which is why open-vocabulary inference survives. Two further differences: our positives are defined by entailment rather than class equivalence or embedding similarity, and radiology compatibility is directional and per-assertion, since two sentences entailed by the same image may assert unrelated facts and are not interchangeable positives.
Image-only SupCon. This lies largely outside our scope, since it removes the image-text objective under study, and with no text encoder there is no zero-shot capability, so only linear probing is comparable. We ran it as a reference point for the bound described above. Following the reviewer's suggestion, we trained a vision encoder alone with multi-label SupCon, positives defined by MIMIC-CXR's 14 report-extracted labels, on the same backbone, data, augmentations, and schedule, evaluated by linear probe. In domain on MIMIC-CXR, where the evaluation label space is the one its positives came from, it reaches 80.3 mean AUC, close to the 81.6 CorLIP-CB sentence obtains zero-shot. On OOD VinDr, whose 28 labels it never saw, it falls to 76.3, below uncorrected vanilla CLIP at 83.1 and more than 10 points below CorLIP-MG sentence at 87.3, despite its probe being fitted on VinDr's own training split while the CLIP results are zero-shot. This is the drawback made concrete: the fixed labels exhaustively define what the model can represent, so distinctions outside them are collapsed rather than left unsupervised, and with no text side there is no route to an unseen label space. CorLIP corrects the target only inside the schema's coverage and leaves standard CLIP mechanics intact outside it, so open-vocabulary generalization is preserved.
3. Schema Granularity
We agree granularity matters, but it does not require per-task tuning. The choice reduces to two cases, neither involving tuning against an evaluation.
When the downstream label space is known, matching the correction schema to it during pretraining simply uses information already in hand, and is the better choice. On MIMIC, CheXbert-13d reaches 81.6 mean AUC at sentence level, above the strongest prior method at 78.9.
When it is not known, which is the general case, the finer schema is uniformly better and can be fixed in advance. MedGemma-30d beats CheXbert-13d on CheXpert, VinDr, and MS-CXR at all three text granularities, nine of nine, while CheXbert-13d wins MIMIC at all three. The split follows granularity rather than the individual evaluation. Under this single fixed configuration, CorLIP-MG sentence beats every prior method on all three: 86.6 vs 83.5 on CheXpert, 87.3 vs 84.1 on VinDr, and 41.6 vs 35.8 on MS-CXR grounding. This is why MedGemma-30d is already the paper's stated default (L246), as the less benchmark-coupled option.
Correction itself does not depend on the choice: across all six extractor by granularity combinations, CorLIP improves over vanilla CLIP on every evaluation (Table 4).
4. Relationship to GLoRIA and AFLoc
Methodological orthogonality. GLoRIA adds a local contrastive objective on top of CLIP's global contrastive loss, and AFLoc extends this to three alignment levels. Both keep paired-identity targets in every branch, so the misspecification we identify is present in their global term exactly as in vanilla CLIP, untouched by the local objectives they contribute. Their axis is the alignment architecture; ours is the target these objectives are trained against. The two are complementary rather than alternative. Following the reviewer's comment we verified this directly with two experiments: (1) original GLoRIA, and (2) GLoRIA with the local branch untouched and the global-branch target replaced by CorLIP-CB compatibility. MIMIC mean AUC improves from 69.1 to 78.8, confirming that CorLIP's contribution is orthogonal to local contrastive methods.
Evaluation breadth. Because our contribution is at the level of the target, our evaluation is organized around the properties a pretraining objective should have, and is thorough in that respect. Beyond in-domain and OOD classification, it covers dense phrase grounding on MS-CXR, trajectory stability across batch sizes from 16 to 2048, data-scaling efficiency from 60K to 120K studies, generality across contrastive loss families with CLIP and SigLIP, and transfer to a different modality and encoder family with 3D CT.
5. Experimental Details
Controlled comparison. Per Appendix E.1, all methods share the same DINOv3 ViT-B/16 image encoder, BioClinicalBERT text encoder, data, augmentations, optimizer, and schedule. CorLIP changes only the target matrix. Projection heads are standard CLIP linear layers; the supervised head is an MLP. Both vision and text backbones are fully fine-tuned end-to-end in all experiments.
Dataset label spaces. MIMIC-CXR and CheXpert share the same 14-class space: Atelectasis, Cardiomegaly, Consolidation, Edema, Enlarged Cardiomediastinum, Fracture, Lung Lesion, Lung Opacity, No Finding, Pleural Effusion, Pleural Other, Pneumonia, Pneumothorax, Support Devices. VinDr uses a 28-class vocabulary: Aortic Enlargement, Atelectasis, Calcification, Cardiomegaly, Clavicle Fracture, Consolidation, COPD, Edema, Emphysema, Enlarged PA, ILD, Infiltration, Lung Cavity, Lung Cyst, Lung Opacity, Lung Tumor, Mediastinal Shift, Nodule/Mass, No Finding, Other Diseases, Other Lesion, Pleural Effusion, Pleural Thickening, Pneumonia, Pneumothorax, Pulmonary Fibrosis, Rib Fracture, Tuberculosis. VinDr's 28 labels do not align with MedGemma-30d's 30 slots (Table 5, Appendix C.1): they differ in granularity, laterality, and category boundaries. MedGemma-30d's stronger VinDr result (Table 4) therefore reflects finer correction preserving clinical distinctions, not schema–evaluation alignment.
MedGemma-30d prompt. Will be added to the appendix; space here is limited.
6. Minor Comments Line 282 / Figure 3: Will correct the reference. Data scaling (line 292): It's hard to add to main text due to the limited space. Embedding visualizations: Will add t-SNE plots comparing vanilla CLIP and CorLIP clusters. Lemma 1 decomposition plot (Q3): Feasible on CLEVR-Radiology where fact states are available. Will include ‖d_sem‖ and ‖d_id‖ over training in the revision.