- Rating
- 4
- Clarity
- 3
- Confidence
- 3
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
The paper studies omission noise in chest X-ray report generation: clinical reports are not exhaustive labels, so a finding can be visible on the image but not mentioned in the report. A model trained on such reports may then learn to omit the same findings. The authors propose PU-DPO, which treats missing mentions as unlabeled rather than negative. They create contrastive report pairs that either mention or omit a target finding, then train with a positive-unlabeled version of DPO. The paper evaluates the method in semi-synthetic omission settings and on CheXpert/MIMIC-CXR with several VLM backbones.
Strengths and weaknesses
I think the paper is going after the right problem. The “not mentioned” != “not present” point is very important in radiology, and the paper makes a good case that standard SFT or reward-based training can inherit this bias. The PU-DPO idea is also neat: it is not just another reward tweak, but a principled attempt to fix the label structure behind the preference signal.
The semi-synthetic experiments are the most convincing part. When positives are deliberately hidden, standard DPO becomes too conservative, while PU-DPO keeps sensitivity higher. That is exactly the failure mode the method is supposed to address, and the comparison to Dr-DPO is useful.
The paper is also reasonably well documented. I appreciated the derivation, the alpha sweep, multiple backbones, two datasets, confidence intervals, prompts, and compute details. This is more complete than many papers in this space.
That said, I am not fully convinced by the real-world clinical evidence. The paper’s core claim is that PU-DPO recovers visually present findings that reports omit. But most of the real-world evaluation still uses labels extracted from reports. This leaves a gap, because those reports are precisely what the paper says are incomplete. The radiologist study helps show that omission noise exists, but it does not really validate that PU-DPO produces clinically better reports on omitted-positive cases.
I also want more evidence that the synthetic edited preference pairs are clean. GPT-OSS 120B is carrying a lot of the training signal here. If the edits add artifacts, change unrelated findings, or make the “presence vs absence” contrast too artificial, then the training signal may not mean what the paper says it means. A length filter is not enough to settle that.
The assumptions are another concern. SCAR/multi-SCAR is convenient, but in radiology omissions are probably not random within a subtype. Mild findings, ICU context, support devices, view quality, co-occurring disease, and clinical indication can all affect whether a radiologist mentions something. The paper admits this, but does not really show how much it matters in practice.
Finally, I would tone down the specificity claim. PU-DPO often improves sensitivity/F1, but the tables show specificity drops in some settings. That may be a reasonable clinical tradeoff, but the paper should call it a tradeoff rather than saying specificity is not compromised.
Questions
-
Can you evaluate PU-DPO on a small radiologist-adjudicated subset of generated reports, especially cases where the original report omits a finding that radiologists mark as present?
-
Can you manually audit the GPT-OSS edited preference pairs? I would like to know how often the edits are clinically valid, preserve unrelated findings, and correctly express the target subtype.
-
How sensitive are the real-world results to alpha estimation errors? The semi-synthetic sweep is useful, but the real setting is the important one.
-
Could you state the specificity result as a sensitivity-specificity tradeoff where appropriate? Some results do show specificity degradation.
-
Can you clarify how to interpret real-world gains measured against report-derived labels, given that the paper’s premise is that report-derived labels are noisy?
Limitations
The current limitations section covers alpha estimation and SCAR, which is good, but it misses several practical issues. I would add the lack of direct radiologist evaluation of generated reports, dependence on GPT-OSS edits, limited pathology/subtype coverage, single-seed reporting, and the fact that sensitivity gains sometimes come with specificity loss.
Paper formatting concerns
No
Final justification
The authors substantially addressed my concerns by adding an evaluation on the radiologist-adjudicated CheXpert test set, real-world sensitivity analysis for alpha, a radiologist audit of the GPT-OSS contrastive edits, and pathology-specific results.
The edit audit suggests that the editor usually performs the requested operation and preserves unrelated findings, although only 62/70 pairs were judged definitively clinically correct. More importantly, the pathology-specific analysis shows that PU-DPO helps recover omitted atelectasis findings but does not improve over standard DPO for cardiomegaly, where the authors detect a statistically significant SCAR violation. This is a useful and honest result, but it also shows that the method’s real-world benefit depends strongly on its assumptions.
The adjudicated-alpha variants are oracle/post-hoc analyses, while the deployable BBE results remain mixed across backbones. Sensitivity gains also sometimes come with lower specificity. I therefore remain positive about the problem formulation, method, and semi-synthetic evidence, but retain a Borderline Accept rating rather than moving to a clear Accept.
We thank the reviewer for their careful reading and thoughtful questions, which allowed us to further clarify and improve our empirical evaluations.
[Q1] Evaluation on adjudicated test set. Please refer to the response for reviewer nvDG [Q2].
[Q2] Auditing contrastive edits. We have created a study for manually auditing the contrastive edits and will include study results with a radiologist in the camera-ready version. In the study, we evaluate the correctness of the edit, the preservation of unrelated findings, and the clinical correctness of the preferred response using the Medgemma base responses, where edits are introduced by GPT-OSS 120B to the on-policy response.
[Q3] Sensitivity to α in real-world settings. We conducted a sensitivity analysis on the real-world radiologist-adjudicated test set and found that the real-world results mirror our semi-synthetic findings. Please refer to the response for reviewer nvDG [Q2] for the result table.
While underestimating α dampens the maximum theoretical benefit of PU-DPO, it still often outperforms both standard DPO and the base model in recall and omission recovery. Crucially, our PU-DPO objective modifies the standard DPO objective purely through an α-scaled loss correction term. This allows us to interpret α as a calibration parameter for the diagnostic threshold, explicitly managing the sensitivity-specificity tradeoff. Therefore, if a training dataset is known to contain hidden positives, using a conservatively estimated α (e.g., the empirical prevalence of labeled positives plus a small ϵ) may provide a safe and effective strategy for recovering them in practice.
[Q4] Specificity degradation. We acknowledge the decrease in specificity compared to the base model in certain settings, and we will update the text to explicitly characterize this as a necessary sensitivity-specificity trade-off. We note that a base model that systematically underdiagnoses will naturally exhibit an artificially inflated specificity, simply because it overwhelmingly defaults to predicting the negative class.
[Q5] Evaluating against noisy report-derived labels. We address the noise in report-derived labels by strictly filtering the evaluation dataset to contain only labeled positives and labeled negatives (where the original report explicitly noted the absence of the pathology). By testing models on this curated distribution, we can evaluate their underlying diagnostic accuracy on a sufficiently large set of real images with known pathology presence. However, this setup likely introduces a distribution shift and does not directly evaluate the recovery of hidden positives. Therefore, we now additionally report results on a test-sample with radiologist-adjudicated labels (see [Q1]) which we will include in the main text of our revised manuscript.