- Rating
- 5
- Clarity
- 3
- Confidence
- 5
- Originality
- 2
- Quality
- 3
- Significance
- 3
Read review
Summary
The paper introduces UltraVoxelGS, a 3D ultrasound reconstruction framework that generates fast volumetric reconstructions and physically realistic renderings from 2D ultrasound scans. The method incorporates ultrasound-specific physical properties, including attenuation, reflection, and scattering, into the rendering process. The authors evaluate the method against several baselines and report improved reconstruction/rendering quality, particularly in SSIM, along with substantially faster reconstruction times. Qualitative results also suggest visually impressive 3D reconstructions.
Strengths and weaknesses
This paper addresses an important technical challenge in ultrasound imaging: reconstructing 3D volumetric information from 2D ultrasound acquisitions. The proposed UltraVoxelGS framework is technically interesting because it incorporates ultrasound-specific imaging physics, including attenuation, reflection, and scattering, into the rendering process rather than treating ultrasound as a generic image reconstruction problem. This is a meaningful strength and improves the relevance of the method for ultrasound data.
The manuscript is generally well written and easy to follow. The literature review includes relevant prior work, and the experimental results are promising. The reported improvements in SSIM over the evaluated baselines are significant, and the qualitative results are visually impressive. Another important strength is the substantial reduction in reconstruction time compared with baseline methods, which is highly relevant if the long-term goal is real-time or near-real-time 3D ultrasound visualization.
However, the clinical motivation needs to be clarified. Not every ultrasound application requires 3D reconstruction from 2D scans. In some domains, such as echocardiography, dedicated 3D probes are already available, while in many other applications 2D ultrasound remains the standard clinical workflow. The paper would be stronger if it clearly identified the intended clinical use case. For example, extended field-of-view ultrasound for scoliosis monitoring, long-bone fracture assessment, thyroid imaging, or other anatomy-specific applications could provide clearer motivation for why 3D reconstruction from 2D ultrasound is clinically necessary.
A related limitation is the lack of discussion of existing industry solutions. Commercial approaches already exist for 3D reconstruction from 2D ultrasound acquisitions, such as PIUR Imaging. The paper should explain how UltraVoxelGS differs from these systems, what limitations it overcomes, and why the proposed method would be clinically or technically advantageous. This is difficult to evaluate without a clearer clinical focus.
The description of live 3D reconstruction during acquisition is also unclear. It is not evident how the system can provide a live 3D view before the acquisition is complete. If the goal is sparse acquisition followed by 3D rendering, this should be stated clearly. If instead the method is intended to reconstruct during scanning and guide the operator toward poorly reconstructed regions, then the paper should describe how this feedback is provided. This is especially important because the introduction suggests novice users may struggle with freehand scanning. Without explicit real-time feedback, it is unclear how a novice user would know where to move the probe to improve missing or low-quality regions. The authors should also discuss whether such an interactive workflow could increase total scan time compared with conventional approaches.
A major weakness is that 3D reconstruction accuracy is not directly evaluated. The paper reports image similarity metrics and qualitative visualizations, but it remains unclear whether the reconstructed 3D anatomy is geometrically accurate. For clinical applications, geometric fidelity may be as important as visual realism. The authors should include or discuss metrics that assess 3D spatial accuracy, such as landmark error, surface distance, volumetric overlap, or comparison against ground-truth 3D ultrasound, CT, MRI, or tracked acquisition data where available.
Another important concern is the nature of Dataset B. Since Dataset B is acquired using a robotic ultrasound system and the authors simulate the data by selecting certain frames, this does not represent a true freehand ultrasound acquisition as illustrated in Figure 1. For a proof-of-concept study this may be acceptable, but the manuscript should avoid describing this as “real-world” freehand acquisition unless actual freehand data are used. The absence of validation on true freehand ultrasound data limits confidence in the practical applicability of the method.
Overall, UltraVoxelGS presents a technically promising and visually impressive framework for fast 3D ultrasound reconstruction. Its incorporation of ultrasound imaging physics and its reconstruction speed are important strengths. However, the paper would benefit from a clearer clinical use case, comparison or discussion relative to existing commercial 3D ultrasound reconstruction systems, direct evaluation of 3D geometric accuracy, and validation on true freehand ultrasound acquisitions.
Questions
What is the primary clinical application targeted by UltraVoxelGS? The paper would benefit from a clearer motivation for why 3D reconstruction from 2D ultrasound is needed in the selected use case.
How does UltraVoxelGS differ from existing commercial 2D-to-3D ultrasound reconstruction solutions, such as PIUR Imaging? Please clarify what technical or clinical limitation the proposed method overcomes.
How is live 3D reconstruction intended to work during acquisition? Is the method reconstructing from sparse views after acquisition, or does it provide real-time feedback to guide the operator toward missing or poorly reconstructed regions?
How would a novice user know where to move the probe to improve the reconstruction? If real-time guidance is part of the intended workflow, the paper should describe the feedback mechanism and whether this affects total scan time.
Can the authors evaluate 3D geometric reconstruction accuracy? Metrics such as landmark error, surface distance, volume overlap, or comparison against a tracked/freehand ground truth would strengthen the validation.
Why was the method not validated on true freehand ultrasound data? Since Dataset B is acquired using a robotic ultrasound system and then subsampled, it may not represent the challenges of actual freehand scanning.
Can the authors revise the terminology around Dataset B? Since the data are simulated from robotic acquisition, describing this as real-world freehand ultrasound reconstruction may be misleading.
Limitations
no i have questions and also see the weakness part
Paper formatting concerns
no concerns
Final justification
All my comments have been clearly addressed. The most important inclusion is the addition of the new true freehand ultrasound evaluation (Dataset C). I strongly suggest that the authors include this new experiment in the final camera-ready version. The work will generate important discussions during the meeting. I have upgraded my score to accept
Meta-review
Summary: the overall initial consensus leans positive, with reviewers finding the core idea technically sound and well-supported. Main strengths: problem formulation is well motivated, proposed method is effective on real and simulated dataset with faster reconstruction times. Main weaknesses: questions regarding the RAA module in evaluation should be further clarified, and lack of discussion on practical clinical use case and dataset consideration.