- Rating
- 5
- Clarity
- 3
- Confidence
- 3
- Originality
- 3
- Quality
- 4
- Significance
- 3
Read review
Summary
The work proposes a unique method in inpainting tumors to CT images through reinforcement learning(Flow-GRPO). Their method utilizes supervised training first, creating an initial result, and uses RL to further enhance the result to match the characteristics of the reference tumor. They show that their method has more realistic features compared to other inpainting models, shown through qualitative and quantitative(Frechet inception distance) results.
Strengths and weaknesses
The idea of using Flow-GPRO as a refinement after a paired supervised model for tumor synthesis is sound and appropriate. They are open about the methods used, but does not provide enough information to justify that they have provided 'how to use the code' without the github repository. The figures and tables seem to require some fixes.
- Figure 3 shows the tumor via overlap of green, which is not ideal to see the texture and realistic feature of the tumor as they claim. I recommend a bounding box or a boundary.
- When qualitatively comparing the methods, I suppose it was done on the same base image. However, without the base image provided, it is hard for the reader to evaluate the exact effects the method had on the image.
- Since the work's non-RL version model has been included in the qualitative results for ablation study, it would be natural to have it in table 1 as well, especially since evaluation metrics for realistic synthesis are still on dispute.
I am not sure if their claim of this being the sole case of using reinforcement learning on medical image synthesis is correct. See [1] for example. I would suggest changing the claim to the first case of inpainting, or first case in tumor synthesis or first case of Flow-GPRO in medical imaging.
Overall, it is innovative and meaningful work, but there should be some small changes in the presentation of the results.
[1] Xu, Chenchu, et al. "Synthesis of gadolinium-enhanced liver tumors on nonenhanced liver MR images using pixel-level graph reinforcement learning." Medical image analysis 69 (2021): 101976.
Questions
Outside of medical imaging, have you seen any cases of Flow-GPRO used? It is reasonable to assume this kind of shape/texture refinement is beneficial in multiple areas. Or, if there were post-process refinement techniques like this but not using Flow-GPRO, it is also worth mentioning.
I am open to increasing clarity scores if the points in limitations are addressed.
Limitations
- Figure 3 shows the tumor via overlap of green, which is not ideal to see the texture and realistic feature of the tumor as they claim. I recommend a bounding box or a boundary.
- When qualitatively comparing the methods, I suppose it was done on the same base image. However, without the base image provided, it is hard for the reader to evaluate the exact effects the method had on the image.
- Since the work's non-RL version model has been included in the qualitative results for ablation study, it would be natural to have it in table 1 as well, especially since evaluation metrics for realistic synthesis are still on dispute.
- I am not sure if their claim of this being the sole case of using reinforcement learning on medical image synthesis is correct. See [1] for example. I would suggest changing the claim to the first case of inpainting, or first case in tumor synthesis or first case of Flow-GPRO in medical imaging.
Paper formatting concerns
I do not see any formatting issues
Final justification
Comments about the table and the phrasing has been addressed. I understand that the figures might be changed later. I have seen other reviewers' comments, and I have decided the strength provided by other reviewers are valid yet not enough to change the review score, and major weaknesses have been answered.
Thank you for recognizing and appreciating our work. We also sincerely appreciate your valuable suggestions for improving our paper. We will address your concerns one by one as follows:
For weakness 1 and limitation 1:
Thank you for your helpful suggestion. Due to the page limitation during the submission stage, we had to reduce the size of the figures to reserve sufficient space for the main text. In the camera-ready version, we will enlarge Figure 3 and follow your suggestion by using bounding boxes to highlight the tumor regions instead of green masks, which may obscure the underlying image textures.
For weakness 2 and limitation 2:
Thank you for pointing out this issue. Similarly, in the revised version, we will include the original input image (clean CT) in Figure 2, allowing readers to more clearly observe the changes in the tumor regions introduced by different methods.
For weakness 3 and limitation 3:
Thank you for pointing out this issue. We have added the MedGRPO (no-RL) comparison experiment to Table 1 in the revised version. Furthermore, to make the experimental results more convincing, we conducted repeated experiments with five different random seeds and report the mean and standard deviation as follows:
4-cancer dataset:
Atlas dataset:
By comparing the results before and after RL fine-tuning, we can observe that the GRPO-based reinforcement learning post-training strategy indeed brings a significant improvement in the overall realism of the generated images.
For weakness 4 and limitation 4:
Once again, thank you for your careful reading and valuable suggestions. After careful consideration, we have decided to revise the statement to “the first work to apply reinforcement learning for tumor generation” to avoid any potential ambiguity.
For question:
Flow-GRPO was originally proposed as a post-training method for natural image generation models, with the goal of improving abstract objectives such as aesthetic quality and text–image alignment. In principle, any Flow Matching-based generative model can adopt this framework for reinforcement learning post-training to optimize objectives that are difficult to address through conventional supervised learning.
In fact, Flow-GRPO is not the only available option for post-training Flow Matching-based models. For example, in our early experiments, we also explored DiffusionNFT [1]. However, because it achieved slightly inferior performance compared with Flow-GRPO, it was not selected for our final framework. Since the primary goal of this work is to develop a high-performance tumor generation method rather than systematically compare different reinforcement learning algorithms, we did not include this comparison in the original manuscript.
Nevertheless, as you suggested, we will add a discussion of alternative reinforcement learning approaches to the Discussion section of the revised manuscript.
Reference
[1] Zheng K, Chen H, Ye H, et al. Diffusionnft: Online diffusion reinforcement with forward process[J]. arXiv preprint arXiv:2509.16117, 2025.