- Rating
- 5
- Clarity
- 2
- Confidence
- 4
- Originality
- 4
- Quality
- 3
- Significance
- 3
Read review
Summary
The manuscript presents a novel generative segmentation method built on flow matching, called MedFlowSeg, to generative medical image segmentation. The key improvements are driven by two attention blocks, one for introducing strong structural priors, and another to model frequency-level information into the framework (and the ablation indeed speak for their integration).
Although I am quite happy about the developed method (it's a very relevant method, considering the known stark advantage of flow matching for reducing sampling steps at inference time), without statistical significance experiments -- I am unsure if the reported results are stochastic ("marginal") gains over MedSegDiffv2 (which seems to be the current SOTA for generative medical image segmentation).
See comments below for more concerns!
Strengths and weaknesses
See details below!
Questions
...achieving strong results on certain benchmarks while exhibiting limited generalization across different modalities and anatomical structures.
Although the papers argue this statement is true for diffusion models in generative segmentation, they do not show any experiments to back this. I suggest the authors to either back these claims with empirical results for catastrophic failures, or tone down their preface for diffusion models.
...are often tailored to specific tasks [4, 22], limiting their generalization across diverse modalities and segmentation scenarios.
Same comment as above. Without empirical backing, it's unfair to make such assumptions. Can the authors either point me to the experiments, or please add such experiments to back their claims?
Moreover, the lack of explicit uncertainty modeling makes them less effective in handling irregular anatomical structures and ambiguous boundaries, leading to suboptimal results in challenging cases.
Although this is mostly true, there's several efforts in context of probabilistic segmentation regime, in particular -- PUNet (https://arxiv.org/abs/1806.05034) and PhiSeg (https://arxiv.org/abs/1906.04045) are the two most successful ones. I suggest the authors investigate and report results of prior methods carefully and share experiments for generative segmentation paradigm prior to diffusion models.
Equation 4 and Equation 5
Reading the equation closely (with lambda and alpha parameter values): 1) Is there a rationale to chose fixed parameter values? 2) The effective value reads to me as Ltotal = Lvel + λLaux -- Ltotal = Lvel + λ (Ldice + αLce) -- Ltotal = Lvel + 0.1 (Ldice + 10 x Lce) -- Ltotal = Lvel + 0.1 Ldice + Lce
If it's downweighting dice loss at the end of the day with no particular reward to cross entropy, isn't the net balancing done by penalizing the dice further? I don't see the rationale for doing this. Do the authors have an ablation study to back such a choice?
Table 1:
The reported results do not seem statistically significant to me. Could you authors report the mean and standard deviation for a 5-fold training run across experiments? If the statistical significance is missing, it's hard to grasp if it's a stochastic run with incremental gains or it indeed performs well consistency!
Table 2:
The results are hard to grasp here. There's a row-wise task and column-wise target task combination studied in this setup. But why though? eg. it doesn't make sense to study Echo-SegNet for gland segmentation in histopathology imagesm etc. I suggest the authors to please streamline the results a bit, i.e. keep the "gray" highlighted results only, to remove noisy results for no reason!
Analysis of Uncertainty
I have a hard time reading much of a difference between MedSegDiffv2 and MedFlowSeg results here (the gains seem super marginal to claim robust predictions in uncertain regions). Can the authors back this with a qualitative heatmap for uncertain region's prediction for both models?
Model Efficiency and Complexity
I am assuming the section includes sampling steps for diffusion models until convergence? If that's the case, I think a fair number to put in would be per-step GFLOPs, and the average number of steps required per method to make the advantage of MedFlowSeg seem visible.
Limitations
The only two highlights for me are: 1) missing experiments for classical generative segmentation experiments (using PUNet, PhiSeg), and 2) missing statistical significance of the proposed methods. There are several points to consider for the manuscript, see my comments above!
Paper formatting concerns
N/A
Final justification
I'm happy about the discussions and presented additional results shared by the authors in the rebuttal and discussion period. And most, if not all, of the doubts are now clear after an engaging discussion.
Thank you for your constructive feedback. We will provide detailed responses to your questions.
Additional Results
Results Across Test Subjects
Results Across Random Seeds
Questions
We thank the reviewer for this comment. Table 2 provides empirical evidence that diffusion-based generative segmentation methods can achieve state-of-the-art performance on individual tasks, while their performance is less consistent across different modalities and datasets. This observation motivated our discussion of task-dependent performance and limited cross-modality consistency.
However, we agree that these results do not directly demonstrate catastrophic failures. We will therefore tone down the corresponding discussion in the introduction and describe the limitation more precisely as inconsistent or task-dependent performance across segmentation settings, rather than implying that diffusion-based methods generally suffer from catastrophic failures.
As noted in our response to Question 1, Table 2 provides empirical evidence that existing diffusion-based generative segmentation methods often achieve strong performance on individual benchmarks, while their results are less consistent across different modalities, datasets, and segmentation settings. This observation motivated our discussion of their task-dependent behavior and limited cross-setting generalization.
However, we agree that the current experiments do not directly establish that these methods are inherently tailored to specific tasks, nor do they isolate task-specific design as the cause of their limited generalization. We will therefore revise this statement to avoid making an insufficiently supported assumption.
Our intention was to contrast diffusion-based generative segmentation with conventional deterministic methods that produce a single segmentation output, rather than to suggest that all prior segmentation methods lack explicit uncertainty modeling. We will revise the introduction accordingly and qualify the statement by referring specifically to deterministic segmentation approaches.
Following the reviewer’s suggestion, where compatible implementations and evaluation settings are available, we will include Probabilistic U-Net and PHiSeg as additional baselines in Tables 1 and 2.
The reviewer is correct that, with λ=0.1 and $ \alpha=10$, the objective can be equivalently written as
Ltotal=Lvel+0.1Ldice+Lce
Our auxiliary loss design was initially inspired by MedSegDiff-V2, which employs the same relative weighting between the Dice and cross-entropy terms, i.e., Ldice+10Lce. In MedSegDiff-V2, however, this auxiliary segmentation loss is applied only when the diffusion timestep t is divisible by 5. In our implementation, we found that applying the auxiliary supervision consistently with a fixed coefficient resulted in more stable performance. We therefore use
Ltotal=Lvel+0.1(Ldice+10Lce)
The relatively larger weight assigned to cross-entropy is motivated by the multi-class nature of our segmentation tasks. The velocity-prediction objective primarily supervises the diffusion denoising process and, by itself, does not explicitly impose sufficiently strong class-discriminative constraints. Cross-entropy provides direct voxel-wise supervision over the semantic classes and penalizes incorrect class assignments, which is particularly important for stable multi-class segmentation. The Dice term complements this supervision by encouraging region-level overlap, but its contribution is downweighted to prevent the auxiliary overlap objective from dominating the velocity-prediction objective.
In the additional results, MedFlowSeg without the auxiliary Dice/CE loss also performs worse than the full model. We attribute this to the insufficient direct optimization signal for the conditioning pathway when gradients are provided only through the flow-matching objective, making the optimization more likely to converge to a suboptimal solution. In our experiments, adding the auxiliary loss noticeably reduced the number of training epochs required and led to faster convergence. These observations suggest that the auxiliary objective provides explicit structural guidance and facilitates optimization.
We agree that reporting only a single aggregate value does not fully demonstrate whether the observed improvements are consistent or attributable to stochastic variation.
Our current Table 4 partially addresses this issue by reporting the Generalized Energy Distance (GED) and confidence interval (CI), which measure distributional alignment and prediction stability, respectively. These results provide complementary evidence regarding the consistency and uncertainty of the generated segmentations.
In the additional results, we conducted additional analyses across test subjects and random seeds. The results across test subjects show that STAPLE-based aggregation improves the mean performance while reducing the variability across subjects. Moreover, the results across independent random seeds exhibit very small standard deviations, indicating that MedFlowSeg is stable with respect to stochastic initialization and training variation.
We agree that a more complete statistical presentation would improve the manuscript. We are also considering adding mean and standard deviation results in Tables 1 and 2.
We thank the reviewer for this comment. Our goal was to compare how specific methods perform across different tasks, datasets, and imaging modalities, thereby revealing their task dependence and cross-task generalization. We agree that the full matrix may reduce readability and will streamline the main table by retaining only the gray-highlighted, task-relevant results.
Since the rebuttal system does not allow additional file or figure uploads, we cannot provide the requested heatmaps at this stage. We are considering improving the visualization in the revised manuscript by adding side-by-side uncertainty heatmaps.
We thank the reviewer for this valuable suggestion. In the revised manuscript, we will add the per-step GFLOPs and the average number of sampling steps required by each method, providing a clearer and fairer comparison of computational efficiency.