- Rating
- 5
- Clarity
- 3
- Confidence
- 3
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper proposes MB-DDPM, a multi-source diffusion bridge framework for many-to-one image translation. Instead of learning a bridge from one source image to one target image, the method constructs stochastic bridges between the target and multiple source observations, and couples them through a unified reverse process to aggregate information across sources. The paper evaluates the method on multi-contrast brain MRI for predicting FLAIR from T1, T2, and PD, and also on CIFAR-10/ImageNet restoration from multiple degraded observations. Results show strong quantitative performance over diffusion and bridge-based baselines, including downstream lesion-volume agreement for the MRI task
Strengths and weaknesses
Strengths
1: Extending diffusion bridge models from one-to-one translation to many-to-one translation is reasonable and meaningful. This setting naturally fits multi-contrast MRI and multi-observation restoration. 2: The method is formulated in a relatively principled way, with multi-bridge forward and reverse processes and a variational objective, rather than only using heuristic late fusion of multiple sources. 3: The experiments are fairly comprehensive. The paper evaluates both medical image translation and natural-image restoration, reports multiple metrics including PSNR, SSIM, FID, and LPIPS, and includes downstream lesion-volume analysis for the MRI task.
Weaknesses
1: The hybrid estimator uses a tunable snr_threshold, but the selection protocol is not fully clear. It seems to be chosen based on CIFAR-10 experiments. The paper should clarify whether the same value is used for ImageNet and MRI, and how sensitive the results are to this choice.
2: The source-disagreement analysis is interesting, but the disagreement metric and its normalization could be explained more clearly, especially when comparing natural-image degradations and MRI modalities.
3: The core conditional-independence assumption among sources given the target (Eq. 9) may not strictly hold in real-world applications such as multi-contrast MRI, where different scans can share correlated artifacts, for example from patient motion or acquisition protocol effects. It would be useful for the authors to discuss how violations of this assumption might affect the performance and robustness of MB-DDPM in practical scenarios.
4: There are several presentation issues and typos that should be corrected, such as smany, multi-brige, brige, FPD vs. FDP, as the number of sources increases, and incomplete phrasing such as which multiple sources
Questions
Questions
1: How robust is MB-DDPM when one or more source modalities are missing or severely corrupted at inference time?
2: Can the authors comment on how memory and inference cost scale with the number of sources and image resolution, especially when moving toward higher-resolution or 3D medical imaging?
Limitations
Yes.
Paper formatting concerns
No major formatting concerns.
Final justification
This paper presents a solid and well-motivated extension of diffusion bridge models to many-to-one image translation. The method is technically principled, with a clear multi-bridge forward/reverse formulation, and the experiments show strong results across both multi-contrast MRI synthesis and natural-image restoration. The rebuttal further strengthens the paper by adding sensitivity analysis for the hybrid estimator, clarifying the source-disagreement metric, and evaluating robustness to corrupted sources. Remaining limitations include the lack of explicit source-reliability modeling and the computational challenge of extending the current 2D implementation to high-resolution 3D medical imaging. Overall, I consider this a strong and useful contribution and maintain my recommendation.
1. W1 We thank the reviewer for raising this important point regarding the choice and sensitivity of the hyperparameter snr_threshold. In Appendix C.4, snr_threshold=6 was selected based on CIFAR-10 as a compromise between distortion-based metrics (MSE, PSNR, and SSIM) and perceptual metrics (FID and LPIPS). The same value was then used for the ImageNet and MRI experiments. We have added a sensitivity analysis to evaluate the robustness of this choice across datasets.
The results show that MB-DDPM performance is relatively insensitive to the exact value of snr_threshold over the evaluated range [0.5-12]. On CIFAR-10, varying snr_threshold from 12 to 0.5 produces only marginal changes across all metrics. For example, MSE varies between 0.000695 and 0.000697, while PSNR and SSIM remain nearly unchanged. Lower values of snr_threshold slightly improve perceptual metrics, whereas intermediate values provide a better balance with distortion-based metrics. This justified that snr_threshold=6 is a stable operating point.
We observe the same overall behavior on ImageNet and MRI (test set of MRI was restricted to randomly selected subset of 1,000 samples due to time). On ImageNet, varying snr_threshold results in MSE values ranging from 0.00312 to 0.00327 and LPIPS values ranging from 0.1797 to 0.1894. On MRI, MSE varies between 0.00735 and 0.00765, while LPIPS varies between 0.0649 and 0.0678. While lower values of snr_threshold tend to improve perceptual metrics, small values (0.5) can slightly degrade distortion-based metrics. Overall, the variation remains limited and does not affect the conclusions of the experiments.
These results indicate that snr_threshold values in the range of approximately 2-6 provide a consistent trade-off between perceptual and distortion-based metrics, with lower values within this range favoring perceptual quality and higher values favoring reconstruction fidelity.
Crucially, the performance superiority of MB-DDPM over the baselines reported in Table 1 are maintained across all tested values.
2. W2 The normalization factor 2/(K(K−1)) corresponds to the inverse of the number of unique source pairs, (2K), and therefore makes D the mean pairwise disagreement among the sources. Since the scale of E depends on the dataset and metric, disagreement values are interpreted within each dataset and metric and are not intended to be directly compared across natural-image degradations and MRI modalities. We clarified this after the definition of the disagreement metric.
3. W3 Concerning the conditional independence assumption, see answer 1. to reviewer L3Qo.
4. W4 We thank the reviewer for pointing us those typos. We have carefully proofread the manuscript and corrected the identified issues.
5. Q1 We thank the reviewer for suggesting an analysis of robustness to corrupted source modalities at inference. In Section 4.1, we evaluate MB-DDPM trained with four source degradations: Gaussian noise, Gaussian blur, JPEG compression (quality factor 5), and 4× bicubic super-resolution (SR4x) on CIFAR-10. Based on our Shapley-value analysis (Appendix E.1.3), these sources have different contributions to reconstruction: Gaussian blur is highly informative, SR4x provides moderate information, while JPEG compression provides relatively limited additional information.
To evaluate robustness, we perturb individual source modalities at inference time. Specifically, we consider three types of perturbations: (i) adding Gaussian noise with σ∈{0.01,0.05,0.1}; (ii) introducing source inconsistency by randomly swapping source pairings; and (iii) reducing the information content of a source by increasing the degradation severity (e.g., stronger blur, lower JPEG quality, or replacing SR4x with SR8x).
The results reveal a clear relationship between source importance and sensitivity to perturbations. Perturbing the weakly informative source has a negligible impact on reconstruction quality, with less than a 1.3% increase in MSE and less than a 1.4% increase in LPIPS even under strong corruption.
In contrast, perturbing highly informative sources leads to substantial degradation. For the Gaussian blur source, even weak Gaussian noise perturbation (σ=0.01) significantly affects performance, increasing MSE and LPIPS by approximately 8× and 7×, respectively. Introducing conflicting blur produces a comparable degradation between weak and strong Gaussian noise perturbations. Removing information with a stronger blur leads to a degradation of similar magnitude to that observed with weak Gaussian noise perturbation.
Perturbing the moderately informative source produces an intermediate effect. Weak gaussian noise (σ=0.01) has a limited impact, with MSE and LPIPS increases of 4.92% and 5.60%, respectively. However, stronger Gaussian noise (σ=0.1) substantially reduces reconstruction quality, leading to approximately 6× increases in both MSE and LPIPS. Further degradation of the SR source, either by using a less granular resolution or introducing conflicting information, also reduces reconstruction quality.
This indicates that at inference MB-DDPM relies less on sources that provide limited additional information about the target image. MB-DDPM can tolerate degradation of sources that provide limited information, but its performance naturally depends on the availability of reliable informative sources. This behaviour is expected for conditional reconstruction models, since sources that contain essential information about the target cannot be arbitrarily corrupted without removing information required for accurate recovery. We will add this analysis to Section 4 and clarify this limitation in Section 5.
We note that the current formulation does not explicitly include a source reliability estimation or adaptive source rejection mechanism and assumes that source will not be corrupted at inference time. A possible future direction is to introduce source reliability modelling or corruption-aware training strategies, where the model is exposed to corrupted sources during training to improve robustness to such inference failures.
6. Q1 Concerning missing sources, see answer 2. to reviewer L3Qo.
7. Q2 Regarding the number of sources K, we discuss this in Appendix E.5 and report runtime scaling in Tables A7-A9. MB-DDPM applies a U-Net to the concatenated inputs (xt,xT1:K) for the conditional estimator. Increasing K only increases the input channel dimension while keeping the U-Net architecture unchanged. Consequently, the number of parameters increases negligibly, from 988.45M for one source to 988.51M for four sources, with limited runtime overhead due to efficient vectorization during sampling.
In contrast, increasing image resolution has a larger impact on computational and memory requirements, as the number of feature activations and spatial operations grows with image size. Therefore, while increasing K has a relatively small effect on model size in our implementation, increasing the image resolution can have a substantially larger impact on both memory usage and inference time. This is reflected in the runtime differences between CIFAR-10 (32×32) and ImageNet (128×128) reported in Tables A7-A9.
The current implementation uses a 2D U-Net, but the framework can in principle be extended to 3D by replacing 2D operations with their 3D counterparts. However, this would substantially increase memory and computational requirements due to the additional spatial dimension and would likely require strategies such as patch-based processing or reduced feature-map sizes for high-resolution volumetric medical imaging.
We have added this discussion to clarify that the favorable scaling with respect to the number of sources does not directly extend to image resolution or dimensionality.