- Rating
- 4
- Clarity
- 3
- Confidence
- 5
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper proposes a unified medical image registration-fusion framework driven by implicit-forward diffusion and time-aware joint optimization, ResFusion. It aims to address two challenges: the absence of real fused ground-truth images and the spatial misalignment between multimodal inputs. To this end, ResFusion introduces an implicit-forward diffusion formulation to bypass standard diffusion training with unavailable fused targets, and further designs a time-aware registration network to progressively estimate deformation fields during the diffusion generation process. Experiments show promising performance in segmentation and registration.
Strengths and weaknesses
Strengths:
- ResFusion addresses the challenges: missing fused ground truth and spatially misaligned multimodal inputs. This is of considerable practical value for the real-world application of image fusion models.
- Instead of relying on a static one-shot registration field, ResFusion allows the deformation field to evolve along the diffusion timesteps, which matches the progressive generation nature of diffusion models. It can be intuitively imagined that this can enhance the performance of registration.
- The registration module provides spatially aligned guidance for fusion, while the fused result imposes feedback constraints on registration, making ResFusion more robust than a simple registration-fusion sequential pipeline.
- Compared with both independent registration-fusion methods and recent joint registration-fusion baselines. ResFusion demonstrates better performance.
Weakness:
- The absence of real fused ground truth is a recognized setting in diffusion-based image fusion, and prior works try to address it using pseudo targets, source-image-driven constraints, or test-time optimization. In this work, the proposed implicit-forward formulation can also be interpreted as a source-image-driven constrained diffusion formulation, since the target fused image is ultimately specified by structural, intensity, and gradient constraints derived from the input modalities. Therefore, the contribution appears to be more of a task-specific integration of existing source-image-driven fusion constraints into a residual diffusion framework.
- Diffusion-based progressive registration has already been explored in prior image registration works, such as DiffuseMorph and DiffuseReg. The authors should more clearly position the contribution of ResFusion as the integration of timestep-aware registration into diffusion-based image fusion.
- Registration clearly guides fusion because the warped image is used as a conditional input. However, the reverse direction, namely fusion guiding registration, seems to rely mainly on indirect gradient back-propagation from the fusion loss. However, the fusion loss itself does not explicitly involve the deformation field or registration error, and there is no dedicated fusion-to-registration constraint showing how the fused result directly refines the deformation field. In other words, the mutual efficacy between image registration and fusion should be more clearly expounded and demonstrated.
- The experiments are conducted on real public medical datasets, but the unaligned setting appears to be simulated by deforming aligned image pairs. It is unclear whether ResFusion has been evaluated on naturally misaligned clinical data.
- The computational cost remains relatively high compared with several models. The authors should discuss the practical implications for clinical deployment, especially in time-sensitive workflows.
Questions
- How is the implicit-forward diffusion different from existing source-image-constrained diffusion fusion methods?
- Is the main contribution the diffusion-based registration itself, or its integration with image fusion? - Since the fusion loss does not explicitly include the deformation-related constraint, how does fusion guide registration? - How does ResFusion perform on real misaligned clinical data?
Limitations
Yes.
Paper formatting concerns
No.
Final justification
The authors have addressed my concerns, and I therefore increase my rating.
Thanks for your careful review. We have the following explanation for your concerns:
Q1 & Weakness 1: .
Thank you for this thoughtful comment. We respectfully clarify that ResFusion is not merely an integration of source-image constraints into a residual diffusion framework. Our work fundamentally investigates how diffusion models can effectively model the image fusion task without explicitly constructing a forward process from real or pseudo-fused targets. Existing methods rely on constructing a standard forward process for diffusion training and therefore typically either use pseudo-fused targets, making performance dependent on pseudo-label quality, or train on the original modality images, creating a mismatch between the training targets and the desired fused output. In contrast, our implicit-forward process bypasses this dependency while incorporating fusion objectives to model the fusion task. We further introduce a time-aware joint registration–fusion framework, where registration and fusion progressively provide reciprocal guidance throughout the diffusion trajectory. Thus, the novelty lies in the implicit-forward fusion training paradigm and progressive joint optimization, rather than a simple combination of fusion constraints and diffusion.
Q2 & Weakness 2 & Weakness 3:
Thank you for this comment. Our contribution is not diffusion-based progressive registration itself, but its integration into diffusion-based image fusion through a time-aware joint optimization mechanism. During training, registration progressively aligns the source modalities to facilitate fusion, while the fusion loss guides deformation refinement at each diffusion timestep. We will clearly articulate these contributions in the revised version.
Cross-modal misalignment introduces structural inconsistencies, duplication, and blurring in the fused image, thereby increasing the fusion loss. Consequently, the fusion loss can indirectly guide the registration network toward more precise deformation estimation. We validate this fusion-guided registration effect by comparing ResFusion with a registration-only variant, which removes the fusion module and retains only the diffusion-based registration module.
ResFusion consistently improves registration across all modality combinations, with particularly pronounced gains on the larger-scale BraTs and Pelvis datasets. Taken together, these registration results and Supplementary Tables 5 and 6 show that both the registration-only and fusion-only variants underperform the complete ResFusion framework. This confirms that the gains arise from the time-aware joint optimization of registration and fusion, rather than from either component. In the revised version, we will clearly explain the mutual effectiveness between image registration and fusion.
Q2 & Weakness 4:
Thank you for raising this concern. ResFusion was directly evaluated on naturally misaligned clinical images and consistently outperformed all competing methods in radiologist-assessed registration quality, fusion quality, anatomical preservation, and overall quality. Specifically, we conducted a blinded clinical user study on 30 real clinical images of the prostate, including five cases with severe deformation and five cases with modality-specific anatomical absence. Two radiologists with three years of diagnostic experience independently evaluated the results using a five-point Likert scale, without access to clinical details or biopsy results. All images were presented in random order to minimize evaluation bias. When their assessments were consistent, the corresponding scores were adopted; otherwise, a senior radiologist with 20 years of experience performed an additional review and made the final decision.
The evaluation covered four dimensions: Registration Quality, which evaluates the alignment of cross-modal anatomical structures; Fusion Quality, which evaluates the fusion of complementary information; Anatomical Preservation, which assesses whether anatomical structures exhibit missing regions or distortions; and Overall Quality, which reflects the overall reliability and clinical applicability of the fused results. Higher scores indicate better performance across all dimensions.
The expert evaluations consistently favor ResFusion across all assessment dimensions, indicating that it generalizes better than the competing methods to clinically realistic misalignment while preserving anatomical structures and producing reliable fused results. Since dense ground-truth deformation fields are generally unavailable in clinical practice, this blinded expert assessment provides clinically meaningful evidence of real-world generalization.
Weakness 5:
Although ResFusion requires more parameters and FLOPs than lightweight models, its computational cost remains practical for clinical deployment. The model can be deployed on standard GPU-equipped workstations, and its inference time is only 0.37 s per image, representing a small fraction of a typical diagnostic workflow. More importantly, the additional computation yields substantially stronger robustness and generalization under challenging clinical conditions. In medical applications, reliable handling of severe misalignment and anatomical variation is often more important than marginal reductions in processing time, as inaccurate fusion may directly affect diagnostic confidence and patient care. We have reported the inference-time comparison with existing methods in Table 9 of the Supplementary Material, reproduced below.
Although lightweight models are faster, our blinded clinical study shows that this efficiency comes with reduced robustness under challenging misalignment and anatomical variations. ResFusion offers a more favorable accuracy–robustness trade-off, while its sub-second runtime remains practical for clinical preprocessing and offline analysis. It is also substantially faster than diffusion-based DDFM and CCF.
As discussed in the Supplementary Material, ResFusion adds only about one minute per epoch. The reverse rollout is performed only when T=4, and gradients through intermediate reverse steps are detached, retaining only the final-step prediction gradient to reduce memory and computational costs. A similar gradient-truncation strategy has been validated in Self Forcing [1]. We will further discuss these deployment and training trade-offs and explore model compression and lightweight architectures in future work.
[1] Huang X, Li Z, He G, et al. Self forcing: Bridging the train-test gap in autoregressive video diffusion[J]. Advances in Neural Information Processing Systems, 2025, 38: 167283-167308.
We sincerely hope that the above answers will solve your concerns and obtain your increase in the score.