- Rating
- 4
- Clarity
- 2
- Confidence
- 4
- Originality
- 2
- Quality
- 3
- Significance
- 3
Read review
Summary
The authors propose SphereFlow for missing modality imputation in medical imaging, which projects different image modalities into a shared hyperspherical latent space using a frozen DINOv2 encoder, and then use flow matching in the latent space to synthesize missing modalities. To address the issue of linear interpolation trajectories leaving the sphere's surface, the authors introduce a time-weighted loss to expand the decoders' domain into the off-manifold interior. The method is evaluated on multi-contrast MRI and CT-MRI translation.
Strengths and weaknesses
Strengths:
- Missing modality imputation is an important problem in medical imaging.
- The core idea of mapping different modalities of the same underlying anatomy to nearby points in a shared space rather than mapping between disjoint manifolds is appealing.
Weaknesses:
- The authors claim that replacing the Gaussian noise source with the observed modality is a contribution. However, defining one domain of a flow model as data rather than Gaussian noise is already well-explored in the literature (e.g., Rectified Flow). Consequently, framing this as a new contribution is overstated.
- The authors define "transport" loosely as a "short-range displacement between nearby points". This definition is ambiguous. It is unclear if this relates formally to "optimal transport," and if so, it lacks the necessary mathematical framework.
- The authors propose two properties for a shared latent space, but the evidence in Figure 2(a) does not fully support the claim that different modalities of the same subject are encoded "much closer" than different subjects of the same modality (blue dots appear closer to each other than blue-red pairs). Furthermore, the specific choice of a spherical manifold is not fully justified over simpler geometries like a plane, which would naturally avoid the off-manifold interpolation issue.
- The authors mentions "shared-encoder alignment" as a training step in Stage 1, and Table 5 demonstrates its critical importance. However, this alignment is never actually explained or mathematically defined in the text. Additionally, for "N-to-N Synthesis", it is unclear how the flow model processes inputs of varying dimensions (e.g., one-source vs. three-source) or whether separate models are trained. The encoder ablation also lacks details on whether decoders were trained under identical conditions.
- There are no qualitative results in the main manuscript. While Appendix F includes examples, it lacks the source images, making it impossible to visually assess the generation quality relative to the input condition.
Questions
- Can the authors precisely define "transport" as used in the formulation? Is this related to formal optimal transport, and if so, can it be described under that framework?
- Why is a known geometry specifically required in the formulation, and why was a hypersphere chosen over a simpler geometry like a plane? A planar geometry would circumvent the off-manifold issues entirely.
- Can the authors explain the "shared-encoder alignment" referenced in Stage 1.
- Can the authors explain how the "N-to-N Synthesis" is implemented? Do the authors train a single flow model for all source-target dimension combinations?
- Can the authors provide the source images for the qualitative results in Appendix F?
Limitations
yes
Paper formatting concerns
no
Final justification
Thank you to the authors for more clarification. I increase my score to borderline accept.
Meta-review
SphereFlow formulates missing-modality imputation as short-range flow matching between observed- and target-modality representations in a shared DINOv2 hyperspherical space. It replaces Gaussian noise with the observed-modality latent and uses a time-weighted decoder loss to cover the near-sphere region traversed by interpolation. The paper provides an off-manifold deviation analysis and reports strong results on multi-modal MRI, CT–MRI translation, and downstream tumor segmentation. However, the state-of-the-art claim is not uniform: Zhang’s method performs better on CT→MRI PSNR and SSIM.
The problem is important, and the short-range transport perspective is conceptually appealing. The method is technically coherent, supported by theory, and evaluated broadly across synthesis settings, ablations, sampling efficiency, and downstream segmentation. Reviewers ToYh and 1Ctp particularly value the consistent results and evidence that generated modalities preserve task-relevant information.
Reviewer iwg2 raises unresolved questions about novelty and terminology: using data rather than noise as a flow source is established, while “transport” is not clearly connected to optimal transport. The central assumptions that DINOv2 provides strong cross-modal compactness and that hyperspherical geometry is preferable to simpler alternatives are insufficiently demonstrated. Important details of shared-encoder alignment, N-to-N synthesis, and encoder ablation controls are unclear. Variance, compute information, and source-conditioned qualitative examples are also missing.
In the rebuttal, please include discussions on: