- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 2
Read review
Summary
The paper proposes flowAlign, a framework to transport representations from one space to the other. The approach has 2 phases where the first phase focuses on learning the flow or trajectory based on the given paired data. The second phase mainly focuses on a model that uses this learned path as a score to learn a mapping function. The authors test the model on a synthetic and two paired datasets, showing improvement compared to the baselines.
Strengths and weaknesses
The main idea is interesting to do the mapping by using the flow as a score for training another model. Also, the theoretical analysis helps with better understanding of the paper. The empirical results of the paper are also improved compared to the baselines.
However, there are several weaknesses in the work.
While MSE, MMD, InforNCE are tested for the synthetic dataset, the results for the real datasets are missing, making it difficult to see if the model adds value in real settings.
The paper overstates the value of the multimodal mapping. In many setting, the multimodal data is used to cover the caveats of uni-modal data. Treating one modality as the reference for mapping by preserving the geometry would lead to introducing target modality shortcomings in the source modality as well.
The theoretical guarantees require specific conditions on the quality of stage-1 velocity learning. How are these assumptions validated in the experiments and practice? Can they be numerically evaluated?
While the results are reported based on mean and std, the statical significance test is missing between the model results and the baselines.
The scope of the evaluation is limited as the authors only use synthetic data and RNA/ATAC datasets for testing. How does the model work on other modalities.
Questions
-
Can the authors report the MSE, MSE + contrastive learning, MSE + MMD, and MSE + neighborhood preservation on real-data?
-
How does the model preserve the source modality specific information? When is this approach harmful compared to general multi-modal integration? Authors need to comment on this.
-
Why is only ATAC/RNA used as test case? Can the authors expand the evaluation and test on other modalities?
-
Can the author report diagnostics on the stage-1 velocity quality as described in conditions of theoretical analysis?
-
Can the authors provide statical significance analysis results? also what are the computational resources used?
Limitations
Yes
Paper formatting concerns
No issues
Final justification
Most of my concerns have been addressed by the rebuttal.
We thank the reviewer for recognizing the central idea, the value of the theoretical analysis, and the empirical improvements. The reviewer’s constructive questions were also very helpful in strengthening the paper and making its claims clearer and more convincing. We address the main concerns below with additional controlled baselines, cross-modal evaluation, field diagnostics, and paired significance tests.
1. Controlled MSE-based baselines
The original experiments compared FlowAlign with single cell multiome integration methods but did not test standard regularizers on the real data. We therefore evaluate MSE, MSE+InfoNCE, MSE+MMD and MSE+Neighborhood Preservation (NP) using the same architecture, data splits, and training protocol.
MSE+NP matches local target geometry. In each minibatch, we select the k=10 nearest neighbors from target-space distances and penalize discrepancies along those target-defined edges:
Lneighbor=Bk1∑i=1B∑j∈Nktarget(i)(a∥y^i−y^j∥22−a∥yi−yj∥22)2,
where a is the mean target-neighbor squared distance in the minibatch. The full objective is L=LMSE+Lneighbor with λneighbor=1. Neighbor selection is nondifferentiable, while gradients flow through mapped-output distances. Thus, this baseline preserves minibatch-local target geometry, not source neighborhoods.
FlowAlign is best on FOSCTTM, cell match, LTA, NMI, and ARI on both datasets. The gains are therefore not reproduced by contrastive, distributional, or structure preservation regularization. Thus, FlowAlign adds values in real settings.
2. Source-private information and multimodal integration
Standalone FlowAlign does not guarantee preservation of information that is unique in the source modality. Its output is constrained to lie in the fixed target space, so source modality specific information that is not represented in the target space may be discarded.
This is an intentional consequence of the problem setting rather than a claim of general multimodal integration. FlowAlign is appropriate when the downstream analysis is explicitly performed in the target space. It can be harmful when the downstream task relies on source-specific signals absent from the target, when both modalities should contribute symmetrically, or when the chosen target representation is incomplete or biased.
However, FlowAlign can be used as a regularizer to retain source modality specific information. Our PeakVI experiment directly tests this case: adding FlowAlign while retaining the peak-reconstruction loss improves FOSCTTM from 0.548 to 0.068, R@1 from 0.000 to 0.046, LTA from 0.047 to 0.815, and NMI from 0.457 to 0.801, while peak reconstruction changes only modestly (AUROC 0.782→0.765, AUPR 0.637→0.630). Thus, FlowAlign alone does not preserve arbitrary source modality specific information, but source specific information can be largely retained when it is explicitly protected by the base objective.
3. Why ATAC/RNA data, and evaluation on other modalities
We use paired multiome data because it matches our setting. It provides exact cell level pairs and a fixed RNA space used for neighborhood, clustering, and annotation analyses. We agree that PBMC and BMMC alone do not demonstrate generalization across modality families. We therefore additionally evaluate FlowAlign on CUBICC, which contains paired bird images and textual descriptions. We encode the images with DINOv3 and the text with SigLIP2, reduce both representations to 128 dimensions using PCA, and learn a mapping from the image space to the text space. The results are:
FlowAlign is best on all three metrics, the consistent improvements show that the method is not specific to single-cell modalities. We will narrow the claim accordingly: the formulation is modality agnostic, with empirical support in single-cell and image-text alignment.
4. Stage-1 field diagnostics
Using the existing σ=0.5 checkpoints, we evaluate the frozen field on held-out data with 32 Monte Carlo samples per cell. The true residual measures its normalized velocity-prediction error along the correct paired source–target path; the shuffled residual measures the same error after randomly replacing the paired target while keeping the source condition fixed. Thus, a low true residual indicates accurate generalization to unseen paired paths, while a substantially higher shuffled residual indicates sensitivity to incompatible endpoints. Confidence intervals are obtained from 2,000 bootstrap resamples.
The field has low residual on unseen correct paths, whereas mismatched targets produce residuals more than three times larger. The residual distinguishes correct from shuffled paths with ROC-AUC above 0.92 on both datasets. These results support the empirical premise that Stage 1 learns accurate paired dynamics and assigns greater path inconsistency to incorrect endpoints.
5. Paired statistical tests and computation resources
Appendix C.3 already reports mean ± standard deviation over three independent runs. We additionally assess whether FlowAlign’s improvements over the strongest non-FlowAlign baselines for each metric are statistically reliable. We jointly resample the same test cells for FlowAlign and the baselines and compute paired-bootstrap 95% confidence intervals and two-sided paired p-values. For NMI and ARI, clustering and metric computation are repeated within each bootstrap resample. Differences are oriented so that a positive value always favors FlowAlign: baselines minus FlowAlign for FOSCTTM, and FlowAlign minus baselines for all higher is better metrics.
On PBMC, FlowAlign significantly improves FOSCTTM, exact cell matching, NMI, and ARI relative to the strongest observed baseline for each metric. The LTA difference is small and statistically inconclusive, so we characterize local label transfer performance as comparable rather than improved. On BMMC, FlowAlign shows statistically supported improvements across all five metrics.
All of our experiment are conducted on a H100 GPU