- Rating
- 4
- Clarity
- 3
- Confidence
- 3
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper proposes Fourier Contour Learning, a compact and traceable representation for cardiac MRI quantification. Instead of predicting dense segmentation masks or directly regressing clinical measurements, the method represents cardiac anatomical boundaries using a small set of Fourier contour coefficients. These coefficients can be decoded into smooth and visually inspectable contours, and the enclosed areas can be computed analytically to derive ventricular volumes.
Based on this representation, the authors develop a query-based contour prediction framework with anatomical queries for cardiac structures and cross-slice attention to incorporate volumetric context. The framework supports multiple forms of supervision, including mask-labeled data, measurement-labeled data, and unlabeled images through contour regularization losses such as edge alignment and scale consistency. Experiments on several public cardiac MRI datasets and an in-house cohort show that the proposed method achieves segmentation performance comparable to strong dense prediction baselines, improves boundary agreement and volume estimation, and provides compact anatomical tokens that can potentially support downstream applications such as vision-language question answering and surface reconstruction.
Strengths and weaknesses
Strengths
The paper is well motivated and addresses a practically important problem in cardiac MRI quantification. The authors identify a meaningful gap between dense segmentation, which is visually interpretable but annotation-intensive, and direct regression, which is compact but less traceable. The proposed Fourier contour representation is a reasonable intermediate form for this task, since cardiac structures such as LV and MYO are relatively smooth and can be represented compactly.
The method is technically coherent. Predicting Fourier coefficients allows the model to reconstruct anatomical contours and analytically compute enclosed areas for volume estimation. This design naturally connects mask supervision, measurement-level supervision, and unlabeled-image regularization. The experiments are reasonably complete, covering multiple CMR datasets and reporting not only Dice but also boundary agreement and volume error.
The paper is generally clear and easy to follow. The motivation, method overview, and qualitative visualizations are well presented. The ablation study also helps clarify the contribution of the main components.
Weaknesses
My main concern is the limited originality. Fourier descriptors and contour-based shape representations are established techniques, and the main contribution here is their adaptation to cardiac MRI quantification. While this adaptation is sensible and well engineered, I do not find it sufficiently novel as a general machine learning contribution.
The method is highly task-specific. Its advantages rely heavily on the relatively regular geometry of cardiac MRI structures, especially LV and MYO. The weaker performance on RV also suggests that the representation is less suitable for more complex anatomy. This limits the broader significance of the approach beyond this particular application.
The experimental comparison is not fully conclusive. The proposed method can exploit mask-labeled, volume-labeled, and unlabeled data, while the segmentation baselines are not given comparable weakly or semi-supervised training settings. Therefore, it is difficult to determine how much of the improvement comes from the Fourier contour representation itself versus the additional supervision sources.
The VLM and surface reconstruction results are interesting but feel more like auxiliary demonstrations than central contributions. In particular, the VLM experiment does not yet show substantial clinical reasoning beyond volume-related question answering.
Overall, I consider this a well-executed and clinically meaningful cardiac MRI paper, but the main contribution appears more suitable for a medical imaging venue than for NeurIPS.
Questions
-
Could the authors provide a more controlled comparison under the same supervision setting? For example, comparing the proposed method with nnU-Net or another segmentation baseline using only the mask-labeled data would help clarify how much of the gain comes from the Fourier contour representation itself, rather than from additional volume-labeled or unlabeled data. My evaluation would increase if the authors can show that the proposed representation remains competitive under matched supervision.
-
Could the authors better justify the novelty of the proposed representation compared with prior Fourier descriptor or contour-based segmentation methods? The current paper shows that Fourier contours are well adapted to cardiac MRI, but it is less clear what the methodological contribution is beyond this task-specific adaptation. A clearer discussion of the difference from existing contour/Fourier-based methods would help assess the originality of the work.
-
Could the authors further analyze the failure cases, especially for RV? Since the method appears less suitable for complex and irregular structures, it would be helpful to show representative RV failure cases and discuss whether the limitation comes from the radial Fourier parameterization, the low truncation order, the choice of contour center, or the supervision design. This would help clarify the practical boundary of the proposed approach.
-
Could the authors provide additional evidence for the benefit of volume-labeled and unlabeled data separately? An ablation that adds mask supervision, measurement supervision, edge alignment, and scale consistency step by step under the same training data split would make the empirical claims easier to interpret. This would help determine whether the weakly/self-supervised components are essential or only provide marginal improvements.
-
The VLM experiment is interesting, but its current role is somewhat unclear. Could the authors clarify whether this is intended as a central contribution or only as a potential downstream application? If it is a central contribution, more meaningful evaluation beyond volume-related QA would be needed. Otherwise, I suggest presenting it more modestly as an exploratory demonstration.
Limitations
The authors have discussed several important limitations, including the weaker Dice performance compared with some dense segmentation models, the reduced suitability of the contour representation for complex RV geometry, and the difficulty of ensuring fully fair comparisons when different supervision types are used.
However, I think the limitation discussion could be further strengthened in two aspects. First, the authors should more explicitly discuss the limited generality of the proposed representation beyond cardiac MRI, since the method relies on relatively smooth and regular anatomical contours. Second, the potential clinical risks of over-smoothed contours should be discussed, especially in abnormal cases where local structural details may be clinically meaningful. A more detailed discussion of failure cases, domain shifts, and the conditions under which human verification is required would make the limitation section more complete.
Paper formatting concerns
I did not notice any major formatting, anonymity, or policy concerns.
Final justification
The rebuttal substantially strengthens the paper, especially through matched-supervision experiments and expanded VLM evaluation. I still have some reservations about whether Fourier contour learning constitutes a sufficiently general methodological contribution beyond this specific application, but the additional evidence addresses my main empirical concerns.
Thank you for your careful reading and thoughtful comments. We appreciate your recognition that the paper is well motivated, technically coherent, and clinically meaningful. We have added experiments under matched supervision, expanded the VLM evaluation to functional reasoning and diagnosis, and evaluated the same representation on abdominal MRI. We also clarify the methodological contribution relative to prior Fourier-based segmentation methods.
Q1. Methodological contribution beyond established Fourier descriptors
We agree that Fourier descriptors themselves are established, and we do not intend to claim otherwise. The contribution is the formulation of Fourier contours as a unified anatomical learning interface rather than only an alternative segmentation output.
Prior contour-based methods generally learn parametric boundaries from dense spatial annotations and evaluate them as segmentation models. In our framework, the same predicted coefficients also receive scalar measurement supervision because their enclosed area is available analytically. This connects a global clinical label to an explicit boundary without introducing a separate regression head.
The representation also enables unlabeled-image learning directly in contour space. Edge alignment uses image gradients to constrain the boundary, while scale consistency constrains how the coefficients should transform under geometric augmentation. These objectives act on the same anatomical representation learned from masks and measurements.
Finally, the anatomy-query features provide fixed-length tokens for downstream reasoning. The additional VLM experiment (Q4 below) shows that these tokens improve EF reasoning and disease classification while substantially reducing the visual-token burden.
The methodological contribution is therefore the differentiable anatomical bottleneck that connects mask supervision, clinical measurement supervision, unlabeled-image regularization, and downstream reasoning through one explicit representation. We will revise the introduction and related work to make this distinction clearer.
Q2. Performance under matched supervision and contribution of additional data
We performed the requested controlled experiment using identical ACDC splits, preprocessing, resolution, phase selection, and mask annotations.
With mask-only supervision, the differences from nnU-Net are 0.50 Dice points for LV and 1.00 point for MYO. The larger RV difference is consistent with the representation limitation discussed in Q3.
The added supervision does not simply produce a uniform improvement from more data and the effects are specific and interpretable. Measurement supervision reduces the mean volume error by 0.56 mL with almost no change in Dice. Unlabeled-image supervision improves mean Dice by 1.06 points. Their combination yields the best overall measurement accuracy.
Our proposed full setting is intended to test a capability that a mask-only pipeline does not naturally provide. A report-derived volume can supervise our contour coefficients because those coefficients analytically determine the measured volume. The same supervision cannot identify a unique dense mask without an additional weak-supervision mechanism. We will separate the mask-only and heterogeneous-supervision comparisons more clearly in the paper.
Q3. RV performance and the practical boundary of the representation
We agree that the radial assumption contributes to the RV gap. The RV is often crescent-shaped and locally concave, particularly at basal and apical levels. A single low-order radius function cannot reproduce every such configuration as accurately as a dense mask.
Fourier truncation contributes as well, but it is not the only factor. Increasing M from 4 to 6 improves RV NSD from 86.37% to 88.03%, while Dice changes little. At M=8, performance decreases. This indicates that higher frequencies recover some boundary detail, but increasing the number of coefficients alone does not fully address center sensitivity or non-star-convex geometry.
Despite lower overlap, the representation remains clinically useful for RV quantification. It reduces RV volume error relative to nnU-Net on all four evaluated cohorts: 8.20 to 7.86 mL on ACDC, 9.49 to 9.04 mL on M&Ms, 12.53 to 11.06 mL on M&Ms-2, and 9.67 to 7.85 mL on ACP. This is an important distinction because the goal is to preserve traceable anatomy and accurate measurement using a compact representation, rather than to optimize Dice alone.
We will add representative RV failure cases and discuss structure-specific orders, multiple local contours, and compact residual deformations as possible extensions.
Q4. Role of the VLM evaluation
The central contribution remains Fourier Contour Learning as a compact and traceable anatomical representation. VLM integration is a downstream validation of why such a representation is useful, rather than a claim that we introduce a general medical VLM.
We agree that the original volume-QA experiment was too narrow. We therefore added a task that uses ED and ES information for ejection-fraction reasoning and cardiac disease classification:
This task requires the model to combine ED and ES anatomy, reason about ventricular function, and use that information for diagnosis. The contour-token model improves both LVEF and RVEF estimation and increases diagnostic accuracy by 17.5 percentage points. At the same time, it reduces the visual-token count by more than 20-fold and approximately halves inference time.
This result directly supports the downstream purpose of the representation. The Fourier model is not only producing another estimate of volume; its anatomy-query features provide an efficient interface for functional and diagnostic reasoning.
Q5. Generality beyond cardiac MRI
We evaluated the same method on an abdominal MRI dataset Abd-MR:
The results demonstrate that the method works beyond cardiac MRI. Without changing the representation, it achieves approximately 89% Dice for liver and kidney segmentation using only 11 coefficients for each contour.
nnU-Net remains more accurate in dense overlap, which is expected for these less regular boundaries. Fourier contours occupy a different point in the representation space. They retain an explicit boundary and substantially more geometric information than a bounding box, while being much smaller and more directly measurable than a dense mask.
The appropriate representation therefore depends on the downstream objective. Dense masks remain preferable when every local boundary detail is required. Fourier contours are attractive when measurement, output compactness, traceability, or efficient multimodal reasoning are also important. We will add the abdominal results and clarify that highly fragmented lesion or strongly non-star-convex structures may require a multi-contour or hybrid representation.
We also appreciate your concern regarding broader significance. While the experiments focus on a clinically important CMR application, the methodological contribution is beyond the cardiac-specific design. The same explicit representation connects dense anatomical supervision, scalar measurement supervision, unlabeled-image regularization, and compact downstream reasoning as demonstrated in Q4 above. The additional abdominal MRI results further show that the formulation transfers beyond cardiac anatomy without architectural modification.
Q6. Over-smoothing, abnormal anatomy, domain shift, and human verification
Fourier truncation can suppress small, high-frequency boundary details. We agree that this is a clinically relevant limitation when a focal contour irregularity is itself the target of diagnosis.
The evaluated CMR cohorts include DCM, HCM, abnormal RV anatomy, and other disease-related shape variation. Across these populations, the method remains competitive in Dice, improves boundary agreement for several structures, and consistently reduces volume error. The multi-center and multi-vendor M&Ms datasets also provide evidence under acquisition-domain variation.
Figure 5 further examines CMR scans with implantable cardioverter-defibrillator artifacts that were not included in training. The contour model preserves the principal cardiac boundaries more consistently than nnU-Net in these examples. We regard this as evidence of robustness to severe image artifacts.
Human verification remains important when the anatomy is highly irregular, when image artifacts obscure the true boundary, or when small focal morphology has direct clinical significance. We will make these conditions explicit in the limitation and broader-impact discussion.