- Rating
- 4
- Clarity
- 4
- Confidence
- 5
- Originality
- 2
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper proposes a novel echocardiography video segmentation framework termed Hierarchical Cognitive Decomposition (HCD), motivated by the hierarchical cognitive process reportedly followed by expert echocardiographers during image interpretation. This work addresses the central challenge of left ventricular segmentation under substantial shape deformation, rapid motion, and ambiguous boundaries by decomposing the task into three sequential stages: target identity recognition ("What"), spatial localization ("Where"), and boundary delineation ("Boundary"). To implement this decomposition, the authors introduce three dedicated modules: Static Identity Anchoring (SIA), Adaptive Gaze Prior (AGP), and Structural Boundary Perception (SBP). Built upon a frozen SAM2-Hiera backbone with lightweight trainable adapters, the method achieves strong performance on CAMUS and EchoNet-Dynamic while maintaining high inference efficiency and a relatively small number of trainable parameters. The paper argues that explicitly embedding clinical cognitive priors into model architecture leads to more effective and efficient echocardiography video segmentation.
Strengths and weaknesses
Strengths: One notable strength of the paper is the clear conceptual framing of the problem. Rather than proposing another generic temporal segmentation architecture, the authors formulate the task through a clinically inspired cognitive hierarchy and establish a relatively coherent correspondence between the three cognitive stages and the proposed network modules. This perspective is intuitively understandable and improves the interpretability of the overall architecture. The explicit decomposition of identity retrieval, localization, and boundary refinement also provides a more structured narrative than many existing memory-based video segmentation approaches.
Weakness:
- The primary weakness lies in the limited methodological novelty beneath the cognitive interpretation. Although the paper presents a compelling cognitive narrative, the actual implementations of SIA, AGP, and SBP largely correspond to existing architectural patterns, including cross-attention-based reference retrieval, previous-mask-guided spatial priors, and multi-scale convolutional boundary enhancement. As a result, it remains unclear whether the performance gains originate from the proposed cognitive decomposition itself or simply from a favorable combination of known design components. The claims of the paper regarding cognitive modeling, therefore, appear stronger than the evidence provided.
- The experimental evaluation lacks sufficiently strong evidence supporting the central hypothesis of cognitive decomposition. Although ablation studies demonstrate the contribution of individual modules, there is no direct validation that the proposed three-stage hierarchy corresponds to human cognitive behavior or that the ordering of the stages is fundamentally important. Alternative decompositions, different module orderings, or non-hierarchical variants are not investigated. Consequently, the paper demonstrates that the proposed architecture works, but not necessarily that the cognitive interpretation is the reason why it works.
- The comparison protocol raises several concerns regarding fairness and completeness. Many baseline results are directly cited from previous papers rather than reproduced under a unified experimental setting. Since the reported performance improvements are relatively small on some benchmarks, stronger and more controlled comparisons are necessary to convincingly establish state-of-the-art status.
- The discussion of generalization remains limited. The proposed method is specifically designed around left ventricular segmentation with a first-frame annotation available. It is unclear whether the approach can extend to multi-structure cardiac segmentation, pathological cases with severe anatomical variation, or more general medical video segmentation tasks. The current experiments provide limited evidence regarding robustness and transferability.
Questions
- The paper's central claim is that cognitive decomposition improves segmentation performance. However, no experiments investigate whether alternative decompositions or different module orderings perform similarly. I encourage the authors to compare multiple decomposition strategies and stage permutations to determine whether the proposed "What → Where → Boundary" sequence is genuinely important or merely one effective implementation.
- The proposed cognitive interpretation would be considerably stronger if supported by direct evidence from human perception studies. The authors may consider incorporating attention-map comparisons or other quantitative evaluations demonstrating alignment between model behavior and expert diagnostic behavior.
- Several baseline methods are reported from prior publications rather than reproduced. Given the relatively small improvements over the strongest competitors, it would be beneficial to reproduce the most recent methods under an identical training protocol and backbone setting to ensure fair comparison.
- The reliance on a single first-frame anchor is a key design assumption. Additional experiments should investigate cases where the initial frame is atypical, noisy, or poorly annotated, as such situations may significantly affect clinical deployment. Robustness analyses under imperfect anchor conditions would strengthen the paper.
Limitations
Although the paper discusses several failure cases, the limitation analysis remains relatively narrow. The authors should more explicitly discuss dependence on first-frame annotation quality, applicability to non-periodic motion patterns, robustness under severe pathology, and potential risks when extending the framework to multi-object segmentation.
Paper formatting concerns
N/A
Final justification
After rebuttal, the authors have addressed most of my major concerns. Importantly, the authors have appropriately narrowed their claims and clarified that HCD is a cognition-inspired decomposition rather than a reproduction of expert cognition. While the methodological novelty remains moderate because the individual operators are largely built upon existing techniques, the explicit decomposition strategy, comprehensive validation, and strong empirical performance make the work a valuable contribution. So I retain my rating.
We thank the reviewer for pressing us on both the source of the decomposition and the evidence for it; we answer both in turn.
Where the decomposition came from, and what the controls show. The methodological novelty lies in the lightweight architectural composition of explicit identity, localization and boundary pathways, motivated in Sec. 2.2 and formalized by the sequential transformations in Sec. 3.2, rather than in any individual operator or a claim of reproducing expert cognition. The three modules were inspired by clinical reading practice, which we abstracted as three questions asked in turn, and each module was introduced to answer one of them. Which structure is being read comes first: depending on the indication a clinician reads the left ventricle, the myocardium or the left atrium, and knows the target before looking for it, whereas the network has no such prior, so we state the target explicitly by keeping the annotated first frame as a reference. A reader who knows the target then looks where it should be, and since consecutive frames are continuous we supply the previous frame's prediction as a spatial prior. With target and region settled, the reader inspects local detail there, so we refine those details with boundary-sensitive filtering.
Under a computational-efficiency constraint, we intentionally instantiate these functions with established lightweight operators; the contribution is not the operators themselves but that identity, localization and boundary delineation are modelled explicitly, instead of being extracted implicitly by end-to-end learning from temporal features.
The submitted order was derived from that intended information flow rather than selected by architecture search. To measure how much the composition strategy and the stage order matter, we compared the submitted cascade with a parallel variant and with every stage order on CAMUS, three independent runs each. Across those runs, mDice / HD95 were 95.27+-0.03 / 2.573+-0.025 mm for SIA-AGP-SBP (submitted), 95.24+-0.02 / 2.563+-0.040 for AGP-SIA-SBP, 95.21+-0.01 / 2.583+-0.032 for AGP-SBP-SIA, 95.20+-0.02 / 2.700+-0.030 for SIA-SBP-AGP, 95.16+-0.03 / 2.603+-0.021 for SBP-AGP-SIA, and 95.05+-0.06 / 2.723+-0.050 for SBP-SIA-AGP. The parallel variant, which computes the boundary branch from the unmodulated f3 and merges it afterwards instead of from the identity-conditioned and localized representation, gave 95.13+-0.02 and 2.727+-0.049 mm.
The submitted cascade had the highest mean mDice, but a 0.03-point margin over the next order does not establish a uniquely optimal sequence. The pattern is consistent across both metrics: the three orders in which localization precedes boundary refinement, and only those three, occupy the top three positions on both metrics, and the parallel control, which removes that dependence by composition rather than by ordering, falls with the lower group. With the position of boundary refinement fixed, exchanging identity conditioning and localization changed mean mDice by 0.01 to 0.11 with no consistent winner. That limited sensitivity matches the computation graph: the first-frame identity reference and the previous-frame spatial prior are both available before current-frame refinement and neither is generated by the other, so exchanging them changes the intermediate representation but not the information supplied. These controls therefore indicate a design preference for localization before boundary refinement, while not establishing a uniquely necessary ordering between identity conditioning and localization.
We will add these controls to the revision and state the contribution accordingly: the three pathways follow the clinical reasoning above, whereas the What -> Where -> Boundary arrangement is one effective instantiation, within which boundary refinement after localization is the pattern indicated by the data. We will also state the scope of the cognitive framing explicitly in the abstract and Section 1: the architecture is modelled on the clinical reading workflow, not claimed to reproduce expert cognition.
Whether the three modules perform the functions they were designed for. As set out above, the design makes target, region and detail explicit in the architecture rather than leaving them to be learned implicitly. The design is inspired by that clinical workflow, and we do not claim that it reproduces the cognitive process of an expert reader.
Whether each module performs its intended function is something we can check. We visualized the attention of SIA and AGP on a test sequence and will add the figure to the appendix. Current-frame LV tokens attend to the LV region of the anchor rather than to the background, whereas a background token attends diffusely, so the identity pathway retrieves the target from the anchor rather than reading it indiscriminately; and the AGP prior stays localized on the LV across frames, so the localization pathway carries the current region. For SBP, the boundary-confidence comparison with and without the module shows the confidence gains concentrated at low-confidence boundary regions rather than in the cavity interior, so the boundary pathway acts where it is intended to. We present these as role diagnostics rather than evidence of alignment with expert behaviour.
Fairness and provenance of the comparisons. For a fair comparison we followed the same evaluation protocol as GDKVM: the same CAMUS split, preprocessing, test cases and metric implementation. Every baseline row except E3SAM2 and EchoVim is therefore taken from the values reported in GDKVM's paper; we added E3SAM2 and EchoVim for coverage of more recent work, and we will mark them in the table as not protocol-verified and exclude them from statistical claims.
We did not rest the small margin on the reported values alone. Retraining HCD and GDKVM three times each under GDKVM's protocol, with each method keeping its own architecture and training settings, gave 95.27+-0.03 mDice and 2.573+-0.025 mm HD95 for HCD versus 95.00+-0.04 and 2.703+-0.015 mm for GDKVM, with HCD better in every run. In the final manuscript the comparison table will label each result as Reported or Reproduced with its protocol status, and statistical claims will be restricted to the controlled reproduction.
Robustness under an imperfect first-frame anchor. We ran this experiment for the rebuttal. Without retraining, we perturbed only the first-frame annotation supplied at inference; the ground-truth masks used for evaluation were unchanged. We swept five perturbation families on CAMUS (dilation, erosion, mixed morphology with translation, pure translation, and irregular Gaussian contour noise), and use anchor Dice for the agreement between the perturbed annotation and its ground truth.
From 95.21 mDice / 2.59 mm HD95 with a clean anchor, contour noise gave 95.06 / 2.65 mm at anchor Dice 0.97, 94.93 / 2.73 at 0.95, 94.72 / 2.85 at 0.92, 94.34 / 3.03 at 0.89, 93.94 / 3.23 at 0.87, and 93.45 / 3.46 at 0.84. Within each family the decline was monotone in perturbation strength and progressive rather than abrupt. At anchor Dice 0.90-0.92 the largest degradation across the five families was 2.20 mDice points and 1.01 mm HD95. Sensitivity depended on error type rather than anchor Dice alone: at nearly identical anchor Dice (0.840 versus 0.838), systematic dilation cost 6.2 mDice points whereas irregular contour noise cost 1.8. Accuracy is not retained under gross perturbation: the most severe setting in our sweep, a rigid translation of the whole annotation by 14 pixels, gives anchor Dice 0.70 and 85.9 mDice. Anchor quality therefore matters, but the effect is graded and error-type dependent rather than an all-or-nothing failure of the sequence. Under contour noise the sensitivity is bounded: reducing anchor Dice from 1.00 to 0.84 cost 1.76 mDice points and 0.87 mm HD95.
Generalisation and limitations. We ran the multi-structure extension for this rebuttal, jointly segmenting the LV cavity, myocardium and left atrium over three runs under the same CAMUS split and semi-supervised protocol as the main experiments, with ground truth available only at the first and last frames of each clip, so its LV-cavity result is directly comparable to Table 1. It adds only 585 trainable parameters (about 0.04% of the trainable budget) and reached 92.05+-0.09 mDice and 3.38+-0.04 mm HD95 averaged over the three foreground structures. Joint training reduced LV-specific accuracy relative to the dedicated model (94.18 versus 95.21 mDice), so the extension is feasible at negligible parameter cost while the dedicated model remains preferable for LV-only analysis.
Our evidence covers two echocardiography benchmarks, trained and tested separately, and so supports consistent behaviour on both rather than demonstrated transferability. Three directions remain open: pathology-stratified robustness under severe anatomical variation; irregular rhythms, where AGP derives frame-dependent spatial guidance from the preceding segmentation state and so assumes no periodicity, but arrhythmic sequences were not evaluated; and non-cardiac medical video.
We will expand the Limitations section accordingly, including first-frame annotation quality and the absence of anchor-quality assessment or fallback, the calibrated scope of the cognitive framing and stage order, the absence of pathology-stratified and irregular-rhythm evaluation, and the risks of a multi-object extension.