- Rating
- 5
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 4
Read review
Summary
This paper proposes Echo-SAM, a zero-shot segmentation method for echocardiography. The main idea is to use a cardiac knowledge graph to guide SAM-style segmentation of unseen anatomical structures. The method uses relation-conditioned graph reasoning and geometry-aware support proposals to generate pseudo-labels for unseen targets, without using their annotations. The paper focuses mainly on zero-shot LV and myocardium segmentation, and reports strong improvements across several echocardiography datasets.
Strengths and weaknesses
Strengths:
-
Segmenting unseen or weakly annotated cardiac structures is a hard problem, especially in ultrasound where boundaries are noisy and texture is often unclear. I like the idea of using anatomical relations instead of relying only on visual similarity or text prompts. The knowledge graph grounding is a strong part of the work, and the relation-to-geometry idea feels meaningful for echocardiography.
-
Using seen structures as anchors and then inferring unseen structures through relation-specific geometry is a sensible direction. The GNN is used not only for prompt enhancement but also for relation weighting, which makes the design more tied together than a simple post-processing prior. The reported gains, especially for myocardium, look quite strong and suggest that anatomical priors are actually helping.
Weaknesses:
-
That said as above, I have some important concerns. First, the method seems highly dependent on accurate localization of the seen anchor structures. If the anchors are wrong, then the graph relation and support proposal may also become wrong. This possible cascading failure is not studied enough. I would like to see sensitivity analysis where anchor predictions are noisy or degraded.
-
Some SAM/box-prompt baselines are evaluated with a full-image box, which is very weak for methods that are designed to use meaningful boxes or points. This can make baselines collapse and makes the gain look larger. A stronger comparison would use heuristic boxes/points from seen anchors or some weak localization strategy.
-
The paper discusses a larger graph, but does not show enough evidence on finer structures like valves/septa or other views. So the generality claim feels a bit stronger than what is actually evaluated.
Questions
- How robust is Echo-SAM when the seen anchor structures are not localized correctly? A simple experiment with noisy or degraded anchor masks would help show whether the method fails gracefully or suffers from cascading errors.
- The box-prompt baselines seem disadvantaged by using full-image boxes. Can the authors add a stronger baseline using heuristic boxes/points from seen structures, or explain clearly why this is not possible? This would make the comparison more fair.
- Can the authors report error bars or standard deviations across runs? The paper claims statistical significance, but the main tables do not show variability.
- Can the method be tested on more unseen structures or views, such as valves, septa, A2C, or PSAX? This would support the broader claim that the graph generalizes beyond LV/myocardium in A4C.
My score would increase if the authors clarify the core implementation details, add fairer baselines, and provide at least some anchor-sensitivity or failure-case analysis. My score would decrease if the strong gains mainly come from weak baseline prompting or if the method is very fragile to anchor errors.
Limitations
No, not fully. The paper discusses the overall challenge, but it should more clearly address limitations around anchor dependency, atypical anatomy/pathology, baseline fairness, and clinical deployment risks.
Paper formatting concerns
N/A
Final justification
The rebuttal addresses my main concerns on anchor sensitivity, baseline fairness, and generalization to abnormal anatomy / other views. Some limitations remain, but they are now clearly acknowledged and the contribution is strong.
We are very grateful to the reviewer gnfF for recognizing the significance of our approach in medical segmentation. We thank the reviewer for the questions on anchor errors, box prompting, variability, and generalization, which help us improve the quality of our paper.
W1/Q1. Errors in seen anchors
We test joint mask-box perturbation and anchor removal separately. For perturbation, all anchors are retained, and each predicted anchor mask receives the same center/scale transform as its box. At level l: mild(<5%), moderate(5%-30%) and severe (30-50%), center displacement is at most l times the box diagonal, while width and height are independently scaled within [1−l,1+l]. We average five perturbation seeds within each run and report mean DSC ± SD over three independent runs. For anchor removal, the complete anchor support, including its mask, box, and relation input, is removed.
Mild and moderate perturbations change DSC by +2.04/+1.67/+3.13 and +1.51/+3.12/+4.48 points. We interpret these perturbations may actually improving the robustness of the model, as ultrasound can introduce motion blur or artifacts, while suitable perturbations allow the model to better adapt to these imaging defects. The Severe perturbation damages localization and decreases DSC by 16.74/23.08/20.85 points, because the anchor has moved far from where the cardiac structure should be or includes more information unrelated to the structure.
We next remove anchors. Within each independent run, we average all removal combinations with the same number of available anchors.
Removing one anchor decreases DSC by 0.91/3.72/1.33 points. With only one anchor, Echo-SAM remains within 1.70/2.47/2.90 points of the all-anchor result. With no anchor, the results match the graph-only ablation because geometric support cannot be generated.
These results show graceful degradation when anchors are moderately inaccurate or partially missing, but also confirm the limitation that severe corruption or loss of every anchor substantially weakens localization.
W2/Q2. Box-prompt baselines
We compare the original protocol with two shared-box diagnostics. The first uses a fixed anatomy-prior box: before evaluation, we specify one coarse category-level box for each cardiac structure (RV/LV/RA/LA/Myo) using only general anatomical experience. The second uses an oracle box derived from target GT. We perform three repeated inference runs without retraining or fine-tuning and report mean DSC ± SD across these runs.
For LV, Echo-SAM remains 9.26 points better with the fixed anatomy-prior box and 11.47 points better with the GT box.
For Myo, every baseline remains below 20 DSC with the GT box, while Echo-SAM reaches 81.71 ± 2.45. Their predicted masks usually include the LV because a box provides location but not the surrounding relation between Myo and LV. The fixed bbox is also coarser than Echo-SAM's relation-specific support and can cover both Myo and the LV structures. At the same time, a fixed bbox has a drawback can only perform coarse positioning; it may include other structures, which could lead to the segmentation of other structures as well. This explains why Echo-SAM decreases from 60.24 to 48.64 under this replacement. Nevertheless, with the same fixed box, Echo-SAM remains 41.12 points above the strongest baseline.
We summarise that the advantage of Echo-SAM is not explained only by the original full-image prompt. The fixed-box protocol directly addresses prompt fairness, while the GT-box protocol measures segmentation with oracle localization and is not presented as zero-shot localization.
Q3. Standard deviations and significance
All rebuttal tables report the sample mean ± run-level SD over three runs. We will include all the statistical-significance statement in our revised manuscript.
W3/Q4. Additional structures and views
We address this question with complementary evaluations of a finer unseen structure and three additional echocardiographic views.
Finer structure and abnormal anatomy. CardiacNet-ASD dataset [1] does not provide a dense interatrial-septum (IAS) mask, but its disease labels allow a quantitative test of whether Echo-SAM's IAS detection confidence carries information about septal absence or discontinuity. We use target-detection confidence as the ASD score, where lower confidence indicates a higher likelihood of ASD. Echo-SAM is not trained or fine-tuned with ASD classification labels or IAS segmentation labels; ASD labels are used only for evaluation. Results are ROC-AUC (%):
Echo-SAM numerically exceeds ResNet3D by 1.46 points but remains below the dedicated supervised disease-classification models. This result is not a substitute for dense IAS segmentation evaluation; instead, it provides disease-level quantitative evidence that the confidence of an unseen finer structure remains informative without ASD-specific supervision.
Additional views. We evaluate direct transfer from A4C without fine-tuning and view-specific adaptation on A2C, PLAX, and PSAX. For PLAX/PSAX adaptation, fine-tuning uses the CardiacUDA training split, model selection uses the validation split, and all reported values use the test split.
Direct transfer reaches 52.77 on A2C-LV, supporting generalization between structurally similar apical views. PLAX/PSAX differ substantially from A4C in visible structures, positions, and morphology, and direct transfer is correspondingly lower at 27.91-36.83 DSC. View-specific fine-tuning improves PLAX-RV/LV by 22.74 / 24.29 and PSAX-RV/LV by 32.18 / 20.05. We therefore interpret the direct results as evidence of transfer between similar views, while the fine-tuned results demonstrate adaptability, rather than direct zero-shot transfer, to more distinct views.
Together, the IAS-associated ASD result and the multi-view evaluation broaden the evidence beyond LV/Myo segmentation in A4C while also defining the current limits of direct generalization.
Q5. Limitations
Echo-SAM may fail when anchors are severely mislocalized, ultrasound boundaries are unclear, the required anatomy is truncated, or abnormal anatomy violates the relations encoded in the graph. Because the graph represents expected normal structures, congenital absence or discontinuity can still produce a false-positive support proposal. These limitations mean that the current method should not be interpreted as a clinically validated diagnostic system.
Nevertheless, Echo-SAM jointly performs detection and segmentation, and its detection confidence provides an initial signal of whether an expected structure is present. As reported in Q4, without ASD classification labels or IAS segmentation labels for training or fine-tuning, Echo-SAM achieves 73.71 ROC-AUC (95% CI: 65.27-83.75) on CardiacNet-ASD. Although this does not eliminate the above failure modes or match dedicated supervised disease classifiers, it shows that Echo-SAM can provide non-trivial zero-shot defect-recognition ability. We will incorporate both these findings and the stated limitations in the revised version.
Reference
[1]. Yang, J., et al., 2024, September. Cardiacnet: Learning to reconstruct abnormalities for cardiac disease assessment from echocardiogram videos. In ECCV.
[2] Hara, K., et al.,: Can spatiotemporal 3d cnns retrace the history of 2d cnns and imagenet? CVPR 2018
[3] Yu, K., et al., Anatomy-guided weakly supervised abnormality localization in chest x-rays. MICCAI 2022
[4] Ouyang, D., et al., Video-based ai for beat-to-beat assessment of cardiac function. Nature (2020)
[5] Mallya, M., Hamarneh, G.: Deep multimodal guidance for medical image classification. MICCAI 2022
[6] Silva-Rodríguez, et al., Constrained unsupervised anomaly segmentation. Medical Image Analysis 2022
[7] Huo, X., et al., Hifuse: Hierarchical multi-scale feature fusion network for medical image classification. Biomedical Signal Processing and Control 2024