acceptodds
Published as a conference paper at NeurIPS 2026

Echo-SAM: Zero-Shot Learning of Unseen Structures via Medical Knowledge Graph Grounding

Jiewen Yang, Xiaomeng Li

Abstract

Segmenting unseen anatomical structures in echocardiographic images is challenging because dense annotations are scarce and ultrasound often presents visually similar textures across different cardiac structures. Current foundation models remain limited in this setting because they treat anatomical knowledge as independent text prompts, overlooking the spatial topology that clinicians use to localize ambiguous structures from their visible neighbors. We propose Echo-SAM, a zero-shot ultrasound segmentation framework that grounds a structured cardiac knowledge graph in visual space through relation-conditioned geometric support inference. Echo-SAM localizes seen structures as anatomical anchors, propagates relational constraints through a knowledge-grounded Graph Neural Network, and enhances text prompts with image-grounded anatomical context. We further introduce a topology-to-geometry mapping that converts graph relations into geometry-aware support proposal scores, yielding posterior-guided support estimates for unseen structures. By treating relation-specific scale, thickness, and offset as latent geometric variables, Echo-SAM adapts graph-derived support proposals to image-specific anchors without relying on fixed coordinate templates. Extensive evaluations on zero-shot echocardiography segmentation benchmarks demonstrate that Echo-SAM substantially outperforms state-of-the-art foundation models, achieving up to 50.42% absolute improvement in Dice score. Code will be publicly available.

Keywords:
Sydney

Reviews

Among:
Shape:
123456this paper, Top 8%
Figure 1. Mean review rating of the reviewed papers at NeurIPS 2026. This paper averages 5.00 over 3 reviews, above 92% of the others.
Reviewer_gnfFOpenReview ↗
Rating
5
Clarity
3
Confidence
4
Originality
3
Quality
3
Significance
4
Read review
Summary

This paper proposes Echo-SAM, a zero-shot segmentation method for echocardiography. The main idea is to use a cardiac knowledge graph to guide SAM-style segmentation of unseen anatomical structures. The method uses relation-conditioned graph reasoning and geometry-aware support proposals to generate pseudo-labels for unseen targets, without using their annotations. The paper focuses mainly on zero-shot LV and myocardium segmentation, and reports strong improvements across several echocardiography datasets.

Strengths and weaknesses

Strengths:

  • Segmenting unseen or weakly annotated cardiac structures is a hard problem, especially in ultrasound where boundaries are noisy and texture is often unclear. I like the idea of using anatomical relations instead of relying only on visual similarity or text prompts. The knowledge graph grounding is a strong part of the work, and the relation-to-geometry idea feels meaningful for echocardiography.

  • Using seen structures as anchors and then inferring unseen structures through relation-specific geometry is a sensible direction. The GNN is used not only for prompt enhancement but also for relation weighting, which makes the design more tied together than a simple post-processing prior. The reported gains, especially for myocardium, look quite strong and suggest that anatomical priors are actually helping.

Weaknesses:

  • That said as above, I have some important concerns. First, the method seems highly dependent on accurate localization of the seen anchor structures. If the anchors are wrong, then the graph relation and support proposal may also become wrong. This possible cascading failure is not studied enough. I would like to see sensitivity analysis where anchor predictions are noisy or degraded.

  • Some SAM/box-prompt baselines are evaluated with a full-image box, which is very weak for methods that are designed to use meaningful boxes or points. This can make baselines collapse and makes the gain look larger. A stronger comparison would use heuristic boxes/points from seen anchors or some weak localization strategy.

  • The paper discusses a larger graph, but does not show enough evidence on finer structures like valves/septa or other views. So the generality claim feels a bit stronger than what is actually evaluated.

Questions
  • How robust is Echo-SAM when the seen anchor structures are not localized correctly? A simple experiment with noisy or degraded anchor masks would help show whether the method fails gracefully or suffers from cascading errors.
  • The box-prompt baselines seem disadvantaged by using full-image boxes. Can the authors add a stronger baseline using heuristic boxes/points from seen structures, or explain clearly why this is not possible? This would make the comparison more fair.
  • Can the authors report error bars or standard deviations across runs? The paper claims statistical significance, but the main tables do not show variability.
  • Can the method be tested on more unseen structures or views, such as valves, septa, A2C, or PSAX? This would support the broader claim that the graph generalizes beyond LV/myocardium in A4C.

My score would increase if the authors clarify the core implementation details, add fairer baselines, and provide at least some anchor-sensitivity or failure-case analysis. My score would decrease if the strong gains mainly come from weak baseline prompting or if the method is very fragile to anchor errors.

Limitations

No, not fully. The paper discusses the overall challenge, but it should more clearly address limitations around anchor dependency, atypical anatomy/pathology, baseline fairness, and clinical deployment risks.

Paper formatting concerns

N/A

Final justification

The rebuttal addresses my main concerns on anchor sensitivity, baseline fairness, and generalization to abnormal anatomy / other views. Some limitations remain, but they are now clearly acknowledged and the contribution is strong.

1 comment

We are very grateful to the reviewer gnfF for recognizing the significance of our approach in medical segmentation. We thank the reviewer for the questions on anchor errors, box prompting, variability, and generalization, which help us improve the quality of our paper.

 

W1/Q1. Errors in seen anchors

We test joint mask-box perturbation and anchor removal separately. For perturbation, all anchors are retained, and each predicted anchor mask receives the same center/scale transform as its box. At level ll: mild(<5%), moderate(5%-30%) and severe (30-50%), center displacement is at most ll times the box diagonal, while width and height are independently scaled within [1−l,1+l][1-l,1+l]. We average five perturbation seeds within each run and report mean DSC ± SD over three independent runs. For anchor removal, the complete anchor support, including its mask, box, and relation input, is removed.

Joint mask-box perturbationCAMUS LV DSCCAMUS Myo DSCHMC-QU Myo DSC
None49.39 ± 1.1060.24 ± 2.8757.09 ± 2.44
Mild51.43 ± 1.6461.91 ± 2.9060.22 ± 3.05
Moderate50.90 ± 2.3963.36 ± 2.6161.57 ± 2.49
Severe32.65 ± 3.5537.16 ± 3.5336.24 ± 3.26

Mild and moderate perturbations change DSC by +2.04/+1.67/+3.13+2.04/+1.67/+3.13 and +1.51/+3.12/+4.48+1.51/+3.12/+4.48 points. We interpret these perturbations may actually improving the robustness of the model, as ultrasound can introduce motion blur or artifacts, while suitable perturbations allow the model to better adapt to these imaging defects. The Severe perturbation damages localization and decreases DSC by 16.74/23.08/20.85 points, because the anchor has moved far from where the cardiac structure should be or includes more information unrelated to the structure.

We next remove anchors. Within each independent run, we average all removal combinations with the same number of available anchors.

Available anchorsCAMUS LV DSCCAMUS Myo DSCHMC-QU Myo DSC
All anchors49.39 ± 1.1060.24 ± 2.8757.09 ± 2.44
One anchor missing48.48 ± 1.3756.52 ± 2.5555.76 ± 2.81
Two anchors missing47.69 ± 1.4957.77 ± 2.0454.19 ± 2.22
No anchor32.93 ± 5.6639.74 ± 2.2735.98 ± 2.70

Removing one anchor decreases DSC by 0.91/3.72/1.33 points. With only one anchor, Echo-SAM remains within 1.70/2.47/2.90 points of the all-anchor result. With no anchor, the results match the graph-only ablation because geometric support cannot be generated.

These results show graceful degradation when anchors are moderately inaccurate or partially missing, but also confirm the limitation that severe corruption or loss of every anchor substantially weakens localization.

 

W2/Q2. Box-prompt baselines

We compare the original protocol with two shared-box diagnostics. The first uses a fixed anatomy-prior box: before evaluation, we specify one coarse category-level box for each cardiac structure (RV/LV/RA/LA/Myo) using only general anatomical experience. The second uses an oracle box derived from target GT. We perform three repeated inference runs without retraining or fine-tuning and report mean DSC ± SD across these runs.

CAMUS-LVOriginalFixed anatomy-prior boxOracle GT box
MedSAM33.60 ± 1.0856.27 ± 2.4879.45 ± 2.30
Med-SA33.44 ± 1.4250.50 ± 2.3568.94 ± 2.71
MemSAM0.00 ± 0.009.64 ± 1.8624.68 ± 1.59
Echo-SAM49.39 ± 1.1065.53 ± 2.7090.92 ± 2.81

For LV, Echo-SAM remains 9.26 points better with the fixed anatomy-prior box and 11.47 points better with the GT box.

CAMUS-MyoOriginalFixed anatomy-prior boxOracle GT box
MedSAM16.95 ± 1.766.51 ± 1.1119.23 ± 1.39
Med-SA6.14 ± 1.567.52 ± 1.8816.67 ± 1.20
MemSAM0.00 ± 0.003.78 ± 1.2817.78 ± 1.64
Echo-SAM60.24 ± 2.8748.64 ± 3.0681.71 ± 2.45

For Myo, every baseline remains below 20 DSC with the GT box, while Echo-SAM reaches 81.71 ± 2.45. Their predicted masks usually include the LV because a box provides location but not the surrounding relation between Myo and LV. The fixed bbox is also coarser than Echo-SAM's relation-specific support and can cover both Myo and the LV structures. At the same time, a fixed bbox has a drawback can only perform coarse positioning; it may include other structures, which could lead to the segmentation of other structures as well. This explains why Echo-SAM decreases from 60.24 to 48.64 under this replacement. Nevertheless, with the same fixed box, Echo-SAM remains 41.12 points above the strongest baseline.

We summarise that the advantage of Echo-SAM is not explained only by the original full-image prompt. The fixed-box protocol directly addresses prompt fairness, while the GT-box protocol measures segmentation with oracle localization and is not presented as zero-shot localization.

 

Q3. Standard deviations and significance

All rebuttal tables report the sample mean ± run-level SD over three runs. We will include all the statistical-significance statement in our revised manuscript.

 

W3/Q4. Additional structures and views

We address this question with complementary evaluations of a finer unseen structure and three additional echocardiographic views.

Finer structure and abnormal anatomy. CardiacNet-ASD dataset [1] does not provide a dense interatrial-septum (IAS) mask, but its disease labels allow a quantitative test of whether Echo-SAM's IAS detection confidence carries information about septal absence or discontinuity. We use target-detection confidence as the ASD score, where lower confidence indicates a higher likelihood of ASD. Echo-SAM is not trained or fine-tuned with ASD classification labels or IAS segmentation labels; ASD labels are used only for evaluation. Results are ROC-AUC (%):

MethodROC-AUC (%)
ResNet3D [2]72.25
AGXNet [3]76.52
EchoNet [4]83.62
DeepGuide [5]85.02
DiffMIC [6]82.81
HiFuse [7]81.08
CardiacNet [1]91.24
Echo-SAM73.71 (95% CI: 65.27-83.75)

Echo-SAM numerically exceeds ResNet3D by 1.46 points but remains below the dedicated supervised disease-classification models. This result is not a substitute for dense IAS segmentation evaluation; instead, it provides disease-level quantitative evidence that the confidence of an unseen finer structure remains informative without ASD-specific supervision.

Additional views. We evaluate direct transfer from A4C without fine-tuning and view-specific adaptation on A2C, PLAX, and PSAX. For PLAX/PSAX adaptation, fine-tuning uses the CardiacUDA training split, model selection uses the validation split, and all reported values use the test split.

ViewTargetDirect transfer DSC (no fine-tuning)DSC after fine-tuning
CAMUS-A2CLV52.77 ± 1.5261.82 ± 1.74
CardiacUDA-PLAXRV (New)36.83 ± 1.3559.60 ± 1.46
CardiacUDA-PLAXLV33.25 ± 1.7857.54 ± 2.51
CardiacUDA-PSAXRV (New)30.11 ± 2.0262.29 ± 1.67
CardiacUDA-PSAXLV27.91 ± 1.8447.96 ± 1.92

Direct transfer reaches 52.77 on A2C-LV, supporting generalization between structurally similar apical views. PLAX/PSAX differ substantially from A4C in visible structures, positions, and morphology, and direct transfer is correspondingly lower at 27.91-36.83 DSC. View-specific fine-tuning improves PLAX-RV/LV by 22.74 / 24.29 and PSAX-RV/LV by 32.18 / 20.05. We therefore interpret the direct results as evidence of transfer between similar views, while the fine-tuned results demonstrate adaptability, rather than direct zero-shot transfer, to more distinct views.

Together, the IAS-associated ASD result and the multi-view evaluation broaden the evidence beyond LV/Myo segmentation in A4C while also defining the current limits of direct generalization.

 

Q5. Limitations

Echo-SAM may fail when anchors are severely mislocalized, ultrasound boundaries are unclear, the required anatomy is truncated, or abnormal anatomy violates the relations encoded in the graph. Because the graph represents expected normal structures, congenital absence or discontinuity can still produce a false-positive support proposal. These limitations mean that the current method should not be interpreted as a clinically validated diagnostic system.

Nevertheless, Echo-SAM jointly performs detection and segmentation, and its detection confidence provides an initial signal of whether an expected structure is present. As reported in Q4, without ASD classification labels or IAS segmentation labels for training or fine-tuning, Echo-SAM achieves 73.71 ROC-AUC (95% CI: 65.27-83.75) on CardiacNet-ASD. Although this does not eliminate the above failure modes or match dedicated supervised disease classifiers, it shows that Echo-SAM can provide non-trivial zero-shot defect-recognition ability. We will incorporate both these findings and the stated limitations in the revised version.

 

Reference

[1]. Yang, J., et al., 2024, September. Cardiacnet: Learning to reconstruct abnormalities for cardiac disease assessment from echocardiogram videos. In ECCV.

[2] Hara, K., et al.,: Can spatiotemporal 3d cnns retrace the history of 2d cnns and imagenet? CVPR 2018

[3] Yu, K., et al., Anatomy-guided weakly supervised abnormality localization in chest x-rays. MICCAI 2022

[4] Ouyang, D., et al., Video-based ai for beat-to-beat assessment of cardiac function. Nature (2020)

[5] Mallya, M., Hamarneh, G.: Deep multimodal guidance for medical image classification. MICCAI 2022

[6] Silva-Rodríguez, et al., Constrained unsupervised anomaly segmentation. Medical Image Analysis 2022

[7] Huo, X., et al., Hifuse: Hierarchical multi-scale feature fusion network for medical image classification. Biomedical Signal Processing and Control 2024

Reviewer_KLijOpenReview ↗
Rating
5
Clarity
3
Confidence
3
Originality
4
Quality
4
Significance
3
Read review
Summary

This work presents a novel framework for zero-shot echocardiographic segmentation that leverages geometric and topological support to guide the segmentation process. The experimental evaluation is thorough and conducted on established echocardiography datasets. The results demonstrate improvements over prompt-based foundation models in zero-shot settings, and the experiments effectively illustrate the contribution of the proposed components. Overall, the paper provides a well-executed validation of the proposed methodology.

Strengths and weaknesses

Echo-SAM is a well-written paper with a comprehensive experimental evaluation that successfully supports its main claims. The presentation is clear, with a logical structure and well-defined goals that make the proposed approach easy to follow. Crucially, the work addresses an important challenge in medical image analysis: how to integrate prior knowledge and guidance into a model's predictions. I believe the core ideas could easily be extended to other applications. To the best of my knowledge, this work is original; combining geometric and topological support within a zero-shot segmentation framework represents a genuinely novel direction.

The main weakness of the paper is the lack of discussion regarding other anatomical regions and how this framework could be expanded to different structures. While focusing on cardiac data is a well-reasoned choice given the extensive literature and available benchmarking datasets, the paper currently misses an opportunity to highlight its broader impact. Because this method has the potential to be used across multiple applications, including a brief discussion on how it could be extended to other anatomies would significantly strengthen the manuscript and showcase its true relevance to the field.

Questions

Could you please comment on how your proposed framework could handle anatomical variations, pathologies, or congenital anomalies where the standard geometric assumptions might not hold true?

Are there anatomical regions or segmentation tasks for which the proposed geometric and topological priors may be less effective?

How sensitive is the method to errors in the image-specific anchors?

Limitations

Yes, the authors have discussed limitations of their work. I would only like to add that I would like to see a discussion regarding other anatomical regions and how this framework could be expanded to different structures. I think focusing on the heart is a well-reasoned choice given the extensive literature and available benchmarking datasets, but it seems like the paper misses an opportunity to highlight its broader impact. Because this method has the potential to be used across multiple applications, including a brief discussion on how it could be extended to other anatomies would possibly strengthen the manuscript.

Paper formatting concerns

N/A

Final justification

The authors have addressed and clarified my main concerns, and I continue to view this piece of work as a valuable contribution to the field.

1 comment

We sincerely thank the reviewer KLij for recognizing the novelty of our approach and its potential to extend beyond cardiac segmentation. We thank the reviewer for the questions about anatomical variation, anchor errors, and extension to other applications, which help us clarify the applicability and limitations of our method. We will address the questions and concerns point by point below.

 

Q1. Anatomical variation and abnormal anatomy

We distinguish continuous anatomical variation from changes in topology. Geometric support inference samples scale, thickness, and offset relative to image-specific anchors, which accommodates continuous differences in anatomy and acquisition. Our experiment in Tables 2 and 3 show that Echo-SAM obtains 57.09 DSC for Myo on HMC-QU, a myocardial-infarction dataset, and 58.99 DSC for LV on EchoNet-Pediatric, supporting transfer across pathology-, age-, and acquisition-related variation without target annotations.

Topology-changing congenital abnormalities are more challenging because the graph encodes expected normal structures and relations. For example, an atrial septal defect (ASD) can make septal tissue discontinuous or partially absent, while the normal LA-RA relation may still generate an interatrial-septum proposal. However, Echo-SAM jointly performs target detection and segmentation, so low target-detection confidence can provide a signal that the expected structure is absent or abnormal.

We evaluated this capability on CardiacNet-ASD dataset [1] by using target-detection confidence as the ASD score (lower confidence indicates a higher likelihood of ASD). Echo-SAM was not trained or fine-tuned with ASD classification labels or target-structure segmentation labels; ASD labels were used only for evaluation. Results are ROC-AUC (%):

MethodROC-AUC (%)
ResNet3D [2]72.25
AGXNet [3]76.52
EchoNet [4]83.62
DeepGuide [5]85.02
DiffMIC [6]82.81
HiFuse [7]81.08
CardiacNet [1]91.24
Echo-SAM73.71 (95% CI: 65.27-83.75)

Echo-SAM numerically exceeds ResNet3D by 1.46 points but remains below the dedicated supervised disease-classification models. Because CardiacNet-ASD does not provide fine-grained labels for the discontinuous septal structures, this result does not directly establish their segmentation accuracy. It nevertheless provides disease-level evidence that Echo-SAM's zero-shot structural detection confidence remains informative under congenital abnormality. Future work will explicitly calibrate target-presence confidence and model pathology-conditioned relations for abnormal anatomy.

 

W1/Q2. Extension to other anatomies

The method is best suited to targets with stable relations to visible anchors and may be less effective for diffuse lesions, variably located lesions or hyperplasia (such as tumors), truncated images, or 3D relations that cannot be resolved from one 2D image. Extension to another anatomy requires: (1) defining anatomy-specific nodes and clinically valid relations, (2) selecting reliably visible anchors with available annotations, and (3) instantiating relation-specific geometric operators for the new target. We think that Echo-SAM can also be suitable for Fetal, carotid, and abdominal ultrasound are plausible future applications because they contain recurring spatial relations.

The CardiacNet-ASD experiment (see our response to Q1) also illustrates a practical evaluation route when fine-grained structure masks are unavailable: disease-level classification labels can test whether the inferred structural confidence retains clinically relevant information. Such classification data provide indirect task-level evidence. For other anatomies, we will therefore combine available disease- or outcome-level labels with structure-level evaluation. However, there is currently a lack of publicly available datasets on these types of diseases, so future research on congenital heart disease data is an important direction for the medical community.

 

Q3. Sensitivity to anchor errors

We first perturb every retained anchor mask and box together, applying the same sampled center/scale transform to both. At level ll (mild <5% / moderate 5-30% / severe 30-50%), center displacement is at most ll times the box diagonal and width/height are scaled within [1−l,1+l][1-l,1+l]. We use five perturbation seeds in each run. All values are mean DSC ± SD over three independent runs:

Joint mask-box perturbationCAMUS LV DSCCAMUS Myo DSCHMC-QU Myo DSC
No perturbation49.39 ± 1.1060.24 ± 2.8757.09 ± 2.44
Mild51.43 ± 1.6461.91 ± 2.9060.22 ± 3.05
Moderate50.90 ± 2.3963.36 ± 2.6161.57 ± 2.49
Severe32.65 ± 3.5537.16 ± 3.5336.24 ± 3.26

The mild and moderate results show no degradation under modest localization errors. We consider that mild to moderate perturbations during pseudo-target construction broaden the spatial support and may reduce sensitivity to uncertainty caused by motion artifacts or blurred boundaries. Severe perturbation causes substantial degradation and identifies the regime in which anchor errors cascade.

We separately remove complete anchor references without perturbing the remaining anchors:

Available anchorsCAMUS LV DSCCAMUS Myo DSCHMC-QU Myo DSC
All anchors49.39 ± 1.1060.24 ± 2.8757.09 ± 2.44
One anchor missing48.48 ± 1.3756.52 ± 2.5555.76 ± 2.81
Two anchors missing47.69 ± 1.4957.77 ± 2.0454.19 ± 2.22
No anchor32.93 ± 5.6639.74 ± 2.2735.98 ± 2.70

With only one anchor, performance remains within 1.70/2.47/2.90 points of the all-anchor result. With no anchor, the results match the graph-only ablation because geometric support cannot be generated.

Thus, the method fails gracefully under modest localization error or partial anchor loss, but remains dependent on at least one sufficiently reliable spatial reference.

 

Q4. Additional views

For PLAX/PSAX, fine-tuning uses the CardiacUDA training split, model selection uses the validation split, and results are reported on the test split. Values are mean DSC ± SD over three independent runs.

ViewTargetDirect transfer DSC (no fine-tuning)DSC after fine-tuning
CAMUS-A2CLV52.77 ± 1.5261.82 ± 1.74
CardiacUDA-PLAXRV (New)36.83 ± 1.3559.60 ± 1.46
CardiacUDA-PLAXLV33.25 ± 1.7857.54 ± 2.51
CardiacUDA-PSAXRV (New)30.11 ± 2.0262.29 ± 1.67
CardiacUDA-PSAXLV27.91 ± 1.8447.96 ± 1.92

Direct transfer reaches 52.77 on A2C-LV, showing generalization to a structurally similar apical view. For the more distinct PLAX/PSAX views, direct transfer trained the model on unseen views reaches 36.83 (PLAX-RV), 33.25 (PLAX-LV), 30.11 (PSAX-RV), and 27.91 (PLAX-LV). However, the fine-tuning significantly improves these results to 59.60 (22.74$\uparrow$), 57.54 (24.29$\uparrow$), 62.29 (32.18$\uparrow$) and 47.96 (20.05$\uparrow$), respectively. These results show direct transfer between similar views and the need for view-specific fine-tuning when the structure layout changes substantially. We will add this evaluation to the Quantitative Analysis subsection.

 

Reference

[1]. Yang, J., Lin, Y., Pu, B., Guo, J., Xu, X. and Li, X., 2024, September. Cardiacnet: Learning to reconstruct abnormalities for cardiac disease assessment from echocardiogram videos. In European Conference on Computer Vision (pp. 293-311). Cham: Springer Nature Switzerland.

[2] Hara, K., Kataoka, H., Satoh, Y.: Can spatiotemporal 3d cnns retrace the history of 2d cnns and imagenet? In: Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition (CVPR). pp. 6546–6555 (2018)

[3] Yu, K., Ghosh, S., Liu, Z., Deible, C., Batmanghelich, K.: Anatomy-guided weaklysupervised abnormality localization in chest x-rays. In: MICCAI. pp. 658–668. Springer (2022)

[4] Ouyang, D., He, B., Ghorbani, A., Yuan, N., Ebinger, J., Langlotz, C.P., Heidenreich, P.A., Harrington, R.A., Liang, D.H., Ashley, E.A., et al.: Video-based ai for beat-to-beat assessment of cardiac function. Nature 580(7802), 252–256 (2020)

[5] Mallya, M., Hamarneh, G.: Deep multimodal guidance for medical image classification. In: MICCAI. Springer (2022)

[6] Silva-Rodríguez, J., Naranjo, V., Dolz, J.: Constrained unsupervised anomaly segmentation. Medical Image Analysis 80, 102526 (2022)

[7] Huo, X., Sun, G., Tian, S., Wang, Y., Yu, L., Long, J., Zhang, W., Li, A.: Hifuse: Hierarchical multi-scale feature fusion network for medical image classification. Biomedical Signal Processing and Control 87, 105534 (2024)

Reviewer_snVeOpenReview ↗
Rating
5
Clarity
3
Confidence
4
Originality
4
Quality
3
Significance
4
Read review
Summary

In this paper the authors propose Echo-SAM which utilizes a cardiac knowledge graph constructed from seen anatomical anchors to derive spatial, topological, and morphological information. These graphs are used to generate proposals for unseen structures and enhance text prompts for guiding SAM3 segmentation. This takes advantage of the inherent geometry of the anatomy to do zero-shot segmentation of cardiac structures on echocardiogram images. The main contributions of this paper include a relation-conditioned medical knowledge graph with learnable node and edge embeddings, a pipeline which maps seen anchors to geometry aware proposals for unseen structures, and echocardiogram zero-shot segmentation Dice improvements of up to 50.42% over current state-of-the-art models.

Strengths and weaknesses

Strengths:

  • The proposed method is technically sound,
  • The paper is well written and well-organized.
  • The significance of this model to the application of echocardiogram images, including the shortcomings of current state-of-the-art approaches is covered thoroughly and the results indicate impactful findings in the segmentation results, particularly for zero-shot settings.
  • The work provides original improvements through expansion of existing SAM3 technologies. The methods are covered thoroughly with provided appendices to allow for reproduction and building upon of results.
  • The design of the Echo-SAM framework, utilizing the cardiac knowledge graphs, is closely tied to the task and data for this use-case, as verified using real-world datasets.
  • Figures were well made and helpful in improving reader understanding.

Weaknesses:

  • More coverage of the limitations or common fail cases of Echo-SAM would be helpful in informing the reader of potential weakness of the model.
  • Additionally, more clarity relating how S_unseen, S_available, and S_geo all relate to each other in terms of categorizing the unseen structures as they move from probable candidates to identified segmentation results would be helpful, as well as clarifying how L_pseudo relates to the S_unseen structures.
  • Providing in-text citations for the state-of-the-art models used in Tables 1-3 would be helpful (currently it looks like models are cited only in the table).
  • More clarity evaluating limitations/weaknesses needed
Questions
  • Quality could be improved by providing more detail regarding shortfalls / limitations / weaknesses of Echo-SAM.
  • Clarity could be improved regarding how S_unseen, S_available, and S_geo all relate to each other in terms of categorizing the unseen structures as they move from probable candidates to identified segmentation results would be helpful, as well as clarifying how L_pseudo relates to the S_unseen structures.
  • Providing in-text citations for the state-of-the-art models used in Tables 1-3 would be helpful (currently it looks like models are cited only in the table).
Limitations

Limitations were covered briefly in the Conclusion of the paper, however, there a figure showing common places where the model underperforms in segmentation (or perhaps this could be added as an example with callouts to Figure 2 or Figure 3) and why, particularly if Echo-SAM underperforms anywhere SOTA models do well, would be helpful.

Paper formatting concerns

N/A

Final justification

Author responses addressed my questions and comments. I am keeping my original positive rating.

1 comment

We appreciate the reviewer snVe for recognizing the technical soundness, clarity, and significance of our approach to medical segmentation. We also thank the reviewer snVe for the constructive suggestions on limitations, notation, and citations, which help us improve the clarity and completeness of our paper. We will address the questions and concerns point by point below.

 

W1/Q1. Limitations and failure cases

One limitation of Echo-SAM is that its knowledge graph encodes the expected structures and relations of normal cardiac anatomy. In patients with an atrial septal defect (ASD), septal tissue can be discontinuous or partially absent, so the normal LA-RA relation may still generate a false-positive interatrial-septum proposal. However, Echo-SAM jointly performs target detection and segmentation: an absent or discontinuous target is expected to receive lower detection confidence, providing a signal for target presence.

We evaluated this capability on CardiacNet-ASD [1] by using target-detection confidence as the ASD score (lower confidence indicates a higher likelihood of ASD). No ASD classification labels or target-structure segmentation labels were used to train or fine-tune Echo-SAM; ASD labels were used only for evaluation (Baseline cite from CardiacNet [1]). Results are ROC-AUC (%):

MethodROC-AUC (%)
ResNet3D [2]72.25
AGXNet [3]76.52
EchoNet [4]83.62
DeepGuide [5]85.02
DiffMIC [6]82.81
HiFuse [7]81.08
CardiacNet [1]91.24
Echo-SAM73.71 (95% CI: 65.27-83.75)

Echo-SAM exceeds ResNet3D by 1.46 points but remains below the dedicated disease-classification models. This comparison is not intended to claim state-of-the-art ASD diagnosis: unlike those supervised classifiers, Echo-SAM is evaluated here through the confidence of a zero-shot segmentation target without ASD-specific training. The result nevertheless shows that its detection output provides non-trivial defect-recognition ability. Explicit target-presence calibration and extension of Echo-SAM to broader segmentation, detection, and diagnosis tasks are important directions for future work. Also, we will incorporate these findings and limitations into our final version.

For the visulization of failure cases: Since the rebuttal interface does not allow an additional figure and the responses are not allowed to contain any links, we will provide the failure analysis in our revised version, which includes:

  1. No anchor is available, or the remaining anchor is severely mislocalized.
  2. Acoustic shadowing or weak boundaries prevent accurate mask prediction.
  3. The image is truncated and does not contain the structures required by the graph.
  4. Abnormal anatomy changes the relations encoded in the cardiac graph.

 

W2/Q2. Relationship among the symbols

SunseenS_{unseen} is the fixed set of anatomical categories that have no target annotations during training. For a target sns_n in SunseenS_{unseen}, Savail(n)S_{avail}(n) contains the localized seen anchors and any model-inferred intermediate supports available before estimating sns_n. Sgeo(Yn∣A,G)S_{geo}(Y_n \mid A,G) assigns a scalar score to each candidate image-specific support Yn=(Mn,bn)Y_n=(M_n,b_n), and the highest-scoring candidate becomes the pseudo target Y~n\tilde{Y}_n. Thus, categories do not move between sets: sns_n remains unseen, while only its image-specific support is estimated and passed to the decoder. We have added the explanation for each symbol that appears in the manuscript and illustrated the relationships between the different symbols.

 

W2/Q3. Relationship between L_pseudo and unseen structures

LpseudoL_{pseudo} is applied only to a target sns_n in SunseenS_{unseen} when its required graph dependencies are available. It matches the selected decoder query to the inferred pseudo target Y~n\tilde{Y}_n using mask BCE/Dice, box L1/GIoU, and confidence terms. It never uses an unseen-structure GT mask or box; if the dependencies are unavailable, no pseudo target or pseudo loss is produced for that target.

 

W3/Q4. Baseline citations

We agree that the baselines should be cited at their first textual mention, not only in the tables. And we have added these methods in our introduction and related work sections.

 

Reference

[1]. Yang, J., Lin, Y., Pu, B., Guo, J., Xu, X. and Li, X., 2024, September. Cardiacnet: Learning to reconstruct abnormalities for cardiac disease assessment from echocardiogram videos. In European Conference on Computer Vision (pp. 293-311). Cham: Springer Nature Switzerland.

[2] Hara, K., Kataoka, H., Satoh, Y.: Can spatiotemporal 3d cnns retrace the history of 2d cnns and imagenet? In: Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition (CVPR). pp. 6546–6555 (2018)

[3] Yu, K., Ghosh, S., Liu, Z., Deible, C., Batmanghelich, K.: Anatomy-guided weaklysupervised abnormality localization in chest x-rays. In: MICCAI. pp. 658–668. Springer (2022)

[4] Ouyang, D., He, B., Ghorbani, A., Yuan, N., Ebinger, J., Langlotz, C.P., Heidenreich, P.A., Harrington, R.A., Liang, D.H., Ashley, E.A., et al.: Video-based ai for beat-to-beat assessment of cardiac function. Nature 580(7802), 252–256 (2020)

[5] Mallya, M., Hamarneh, G.: Deep multimodal guidance for medical image classification. In: MICCAI. Springer (2022)

[6] Silva-Rodríguez, J., Naranjo, V., Dolz, J.: Constrained unsupervised anomaly segmentation. Medical Image Analysis 80, 102526 (2022)

[7] Huo, X., Sun, G., Tian, S., Wang, Y., Yu, L., Long, J., Zhang, W., Li, A.: Hifuse: Hierarchical multi-scale feature fusion network for medical image classification. Biomedical Signal Processing and Control 87, 105534 (2024)

Comments on the paper

1 comment
Meta-review

The reviewers are generally positive about the paper and recognize the proposed method as a technically sound and well-motivated framework for zero-shot echocardiographic segmentation. At this stage, the authors should use the rebuttal to address the following points, which are most relevant to the final discussion:

  1. Please address Reviewer gnfF’s and Reviewer KLij’s concerns regarding the dependence of Echo-SAM on accurate localization of the seen anchor structures.
  2. Please respond to Reviewer gnfF’s concern that some box-prompt baselines may be disadvantaged by using full-image boxes.
  3. Please address Reviewer gnfF’s and Reviewer KLij’s questions about the extent to which the proposed geometric and topological priors generalize beyond the evaluated structures and views.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Related papers

Loading the map…

Discussion (0)

Sign in to comment.