- Rating
- 4
- Clarity
- 2
- Confidence
- 4
- Originality
- 3
- Quality
- 2
- Significance
- 2
Read review
Summary
This paper introduces a new task termed Surgical Reasoning Segmentation, where a model is required to infer a target surgical instrument or anatomical structure from an implicit clinical query and generate a pixel-level segmentation mask. To support this task, the authors construct SurgSeg-14K, a benchmark containing over 14K image-mask-query pairs collected from multiple surgical datasets. The proposed framework, SurgReasoner, decomposes the task into (1) reasoning-based spatial prompt generation using a multimodal LLM and (2) mask generation using a frozen SAM2 segmentation backbone. The reasoning module is optimized via GRPO-based reinforcement learning with a dynamic difficulty-aware advantage reweighting strategy. The paper reports improvements over several general-purpose, medical-domain, and grounding-oriented MLLMs on the proposed benchmark.
Strengths and weaknesses
Strengths
- The proposed architecture decouples reasoning from segmentation by optimizing only the MLLM while keeping the segmentation model frozen. This design is computationally efficient and avoids retraining a large segmentation backbone.
Weaknesses
- Insufficient positioning with respect to existing referring segmentation literature. The paper repeatedly claims that existing surgical segmentation and VQA benchmarks do not support this task. However, the proposed setting appears highly related to referring image segmentation / reasoning segmentation, where language expressions are used to identify target regions.
- The motivation for implicit queries is not sufficiently justified. A central design choice of SurgSeg-14K is converting explicit targets into implicit descriptions. However, the paper never convincingly explains why this setting reflects realistic surgical practice. In actual clinical workflows, surgeons and trainees typically communicate using explicit instrument names and anatomical terminology. Therefore, why is the implicit formulation preferable?
- The necessity of reinforcement learning is not fully established. The core methodological contribution is RL-based optimization with dynamic difficulty-aware reweighting. However, the improvement from SFT to RL is shown only on the newly proposed benchmark. There is no evidence that RL provides benefits beyond this specific dataset construction. The paper does not evaluate whether the proposed strategy improves existing reasoning segmentation or referring segmentation benchmarks.
- Benchmark construction relies heavily on GPT-4o-generated annotations. The benchmark is largely generated using GPT-4o-produced descriptions, queries, and reasoning trajectories. The paper acknowledges that only a subset of samples is reviewed by experts. This raises several concerns, including: (1) GPT-4o may hallucinate descriptions or reasoning chains. (2) Only a random subset is manually verified. (3) No estimate is provided regarding annotation error rates. (4) It remains unclear how trustworthy the reasoning trajectories are.
- Experimental comparisons are not entirely fair. The paper explicitly states that SurgReasoner is trained on SurgSeg-14K, whereas most baselines are evaluated in an off-the-shelf prompting setting. This creates a substantial fairness issue.
- The segmentation evaluation is heavily dependent on SAM2. All methods ultimately rely on the same SAM2-based segmentation pipeline. It remains unclear whether the proposed RL strategy generalizes to other segmentation models.
Questions
- Relationship to referring segmentation. How does the proposed task fundamentally differ from existing referring image segmentation or reasoning segmentation settings? Why are comparisons against established referring segmentation methods absent?
- Real-world motivation. Can the authors provide concrete surgical scenarios where clinicians naturally use implicit descriptions instead of directly naming instruments or anatomical structures?
- RL generalization. Would the proposed dynamic difficulty-aware reweighting strategy still provide gains on existing referring segmentation or grounding benchmarks outside SurgSeg-14K?
- Dataset quality. Only a subset of generated samples is reviewed by experts. What percentage of the dataset was manually inspected? What was the observed error rate?
- Dataset licensing and release. The benchmark combines multiple public datasets and one private dataset. Are redistribution rights available for all source datasets? Will the benchmark be fully released? If the private dataset cannot be released, how will reproducibility be ensured?
- Spatial prompts. The framework predicts two key points (P1 and P2) in addition to the bounding box. Why are two points required? One point appears related to the centroid. What is the semantic role of the second point? Was a single-point formulation evaluated?
- Ablation of reward design. The reward contains multiple manually weighted components. How sensitive are results to λf, λs, λiou, λedge, λpdice, and λdistance? Could a simpler reward achieve similar performance?
- Objective difficulty weighting. Table 2 shows that objective difficulty improves Dice but slightly decreases IoU. Why does emphasizing difficult samples lead to worse localization accuracy while improving segmentation quality?
Limitations
Yes
Paper formatting concerns
N/A
Final justification
Thank the authors for their detailed response. The rebuttal addresses or partially addresses most of my major concerns, particularly by adding referring segmentation baselines, demonstrating the generalization of the RL strategy on ReasonSeg, clarifying the dataset review process, and providing additional ablations. Although some limitations remain regarding real-world motivation and dependence on SAM2, the new evidence substantially improves my confidence in the work. I therefore raise my score to 4 (Borderline accept).
Many thanks for your valuable comments and questions, which greatly help us improve this work. We address your questions as follows.
Q1. Relationship to referring segmentation. How does the proposed task fundamentally differ from existing referring image segmentation or reasoning segmentation settings? Why are comparisons against established referring segmentation methods absent?
A1. We have discussed this distinction in our related work. We clarify that the implicit reasoning queries in our work target future interactive surgical AI systems, rather than compensating for surgeons’ lack of anatomical knowledge. They represent latent surgical intent that guides models to identify clinically relevant entities under specific operative contexts. Unlike traditional segmentation with predefined categories, our task requires models to infer the target based on procedural goals and contextual understanding.
Existing surgical segmentation methods mainly focus on fixed anatomical structures or instruments, while general-purpose MLLMs lack precise pixel-level grounding for open-ended clinical queries. For example, the query “What tissue structure must be gently displaced or avoided in this step?” does not explicitly name the target; the model must understand the surgical context and infer that the liver is relevant because it may obstruct exposure of the esophagogastric junction.
We introduce clinically grounded reasoning traces that bridge surgical intent with pixel-level localization, enabling models to infer what to segment and why before generating the mask. This advances surgical segmentation from static recognition toward intent-driven surgical scene understanding. Regarding comparisons with referring segmentation methods: SAM4MLLM in Table 2 is a representative RS method. Since referring segmentation methods are inherently designed for explicit queries rather than implicit reasoning, direct comparison on our task is of limited reference value. Nevertheless, we supplemented our evaluation with additional RS baselines, as shown in the table below. SurgReasoner consistently outperforms all RS-based methods across all metrics.
Q2. Can the authors provide concrete surgical scenarios where clinicians naturally use implicit descriptions instead of directly naming instruments?
A2. We appreciate the reviewer’s comment. Our task is related to referring segmentation (RS) but differs in the nature of the query. Existing RS methods typically assume that the target entity is explicitly described (e.g., “segment the liver”), while our task introduces implicit surgical intent queries, where the target must be inferred from procedural goals and surgical context before localization.
For example, the query “What tissue structure must be gently displaced or avoided in this step?” does not directly specify the target anatomy. The model must understand the operative context and infer that the liver is relevant because it may obstruct exposure of the esophagogastric junction. Therefore, our task requires reasoning about which entity is clinically relevant and why, beyond conventional language grounding.
We introduce clinically grounded reasoning trajectories that bridge surgical intent with pixel-level localization, advancing surgical segmentation toward intent-driven surgical scene understanding. We agree that RS methods are important baselines and have supplemented comparisons with representative RS approaches, including LISA-7B-LLaVA1.5, LISA-13B-LLaVA1.5, and SAM4MLLM-8B, under the same evaluation protocol. SurgReasoner consistently outperforms these methods, demonstrating the benefit of surgical intent reasoning.
Q3. RL generalization. Would the proposed dynamic difficulty-aware reweighting strategy still provide gains on existing referring segmentation or grounding benchmarks outside SurgSeg-14K?
A3. To verify generalization beyond SurgSeg-14K, we evaluate on ReasonSeg, a standard reasoning segmentation benchmark. Models are trained on RefCOCOg and zero-shot evaluated on ReasonSeg-val. Our difficulty-aware reweighting consistently improves over standard GRPO, confirming general gains beyond the surgical domain.
Q4. Only a subset of generated samples is reviewed by experts. What percentage of the dataset was manually inspected? What was the observed error rate?
A4. We appreciate the request for more details. SurgSeg-14K contains approximately 14,000 instances. We conducted a 50% stratified sample review (7,000 instances) as a first-pass by 8 medically trained student reviewers, evaluating query plausibility, target uniqueness, and mask-rationale consistency. Borderline/uncertain cases (e.g., ambiguous functional states, multiple similar instruments) were escalated to 3 clinical experts for secondary review and final decision-making. Across the reviewed subset, approximately 10-15% of samples required text-only corrections (e.g., clarifying spatial references), and approximately 3-5% were rejected/removed due to unrecoverable inconsistencies. We will add these detailed statistics, inter-reviewer disagreement resolution criteria, and examples of corrected/rejected cases to Appendix A.
Q5. Dataset licensing and release. The benchmark combines multiple public datasets and one private dataset. Are redistribution rights available for all source datasets? Will the benchmark be fully released? If the private dataset cannot be released, how will reproducibility be ensured?
A5. We are committed to open science and plan to fully release all associated resources upon publication. Specifically, we will release via GitHub and Hugging Face Datasets: images from all public source datasets (where licenses permit), binary masks, implicit queries, reasoning trajectories, derived spatial prompts, and all construction and evaluation code. We also plan to release the annotations (queries, reasoning trajectories, and masks) for the private clinical subset under a data use agreement. In addition, model weights trained on the full SurgSeg-14K and the corresponding training code will be made publicly available to ensure full reproducibility.
Q6. Why are two points required? One point appears related to the centroid. What is the semantic role of the second point? Was a single-point formulation evaluated?
A6. This two-point design is motivated by empirical observation. We validated this with preliminary SAM2 experiments prior to finalizing the design — two-point prompting consistently outperformed single-point prompting in segmentation quality, confirming that broader spatial coverage leads to more accurate and complete mask prediction.
Q7. How sensitive are results to λf, λs, λiou, λedge, λpdice, and λdistance? Could a simpler reward achieve similar performance?
A7. The reward function formulation is not the core contribution of this work — we directly adapt standard segmentation metrics as reward signals with task-specific adjustments. The core contribution of this paper is the Dynamic Difficulty-Aware Advantage Reweighting strategy, not the design of reward weights. We select six reward components to evaluate segmentation quality from multiple complementary dimensions: reasoning capability (Format), region overlap (IoU/Dice), pixel-level accuracy (Focal), boundary quality (Edge), and spatial consistency (Distance). Since each component captures a distinct and equally important aspect of segmentation quality with no natural priority ordering among them, we assign uniform weights: λf=λs=λiou=λedge=λpdice=λdistance=1
A single reward signal (e.g., IoU-only) can provide an optimization signal but fails to cover all evaluation dimensions simultaneously. To validate this design, we conduct ablation experiments by removing individual reward terms. As shown below, removing either the IoU reward or the reasoning format reward leads to notable performance drops, confirming the necessity of multi-dimensional reward supervision. We will supplement complete sensitivity experiments for different λ scaling factors in our appendix.
Q8. Table 2 shows that objective difficulty improves Dice but slightly decreases IoU. Why does emphasizing difficult samples lead to worse localization accuracy while improving segmentation quality?
A8. Great observation. Objective difficulty is defined purely by mask size (smaller targets get higher weights). Over-emphasizing extremely small targets during RL can cause the predicted bounding boxes to become overly tight or "shrink" towards the tiny foreground, slightly reducing box IoU. However, because these small targets often have high-contrast boundaries, the mask Dice score (which measures pixel overlap within the prompted region) improves. Our dynamic fusion strategy resolves this trade-off by incorporating subjective difficulty (rollout correctness), which prevents overfitting to the smallest outliers and achieves the best balance between IoU (44.22) and Dice (44.78).