- Rating
- 5
- Clarity
- 4
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper studies why SAM-family models fail on point prompts despite succeeding with box prompts on the same image and target. The authors localize the failure to the first image-to-token cross-attention update in the decoder, show that ~50 sparse autoencoder features close a large portion of the gap, and propose the Causal Bottleneck Adapter, a lightweight residual module placed at this identified bottleneck.
Strengths and weaknesses
Strengths
- The paper studies how to make point prompts more efficient in using SAM-family models by closing its gap between box prompts, which is a practical and important problem.
- The paper is well organized with clear questions defined and reasonable experiment design. It reveals the key observation that the box-point performance gap concentrates at the first image-to-token cross-attention update and that this failure is mediated by a sparse set of approximately 50 feature directions out of 4,096, enabling a lightweight and causally grounded repair.
Weaknesses
- A key question to ask when bridging the gap between box-prompt and point-prompt is what happens when a point prompt is ambigous (e.g. when it lands on overlapping or nested structures), which is a common scenario in the medical imaging settings the paper targets. The paper fails to address it.
- It would be interesting to see how CBA could be extended to handle multiple-point prompts, as single-point prompts may be insufficient in certain scenerios, as laid out in Weakness 1.
- Results are aggregated by modality and dataset, but each dataset may have multiple classes (e.g., thirteen organs in FLARE22). There is no analysis of how CBA performance varies across object types, sizes, or shapes. Small or irregular structures may behave differently from large well-defined ones, which is worth discussing.
- There is no learning curve analysis showing how performance scales with training set size, which is particularly relevant for practitioners deploying CBA on new modalities or devices.
Questions
- What happens when a point lands on overlapping or nested structures? A targeted evaluation on cases with known structural overlap would clarify the method's practical scope.
- Please report CBA rescue fraction broken down by object type or size (e.g., per organ class in FLARE22).
- Please provide a learning curve showing CBA performance as a function of training set size.
Limitations
Yes
Paper formatting concerns
N/A
Final justification
I thank the authors for the detailed rebuttal. The additional experiments satisfactorily address my concerns regarding ambiguous and multi-point prompts, performance across different target characteristics, and data efficiency. These results confirm my original assessment that the paper is technically solid and practically relevant. I therefore maintain my Accept rating.
Response to Reviewer SsZF
We thank the reviewer for recognizing the practical importance of improving sparse-point prompting, the clarity of the paper, and the value of the identified sparse bottleneck. We also appreciate the constructive suggestions on ambiguous and multi-point prompts, object-level heterogeneity, and data efficiency.
Weakness 1 & Question 1. Ambiguous Points on Overlapping or Nested Structures
A single positive point is formally underdetermined when it lies inside multiple valid target masks. CBA repairs point-conditioned routing for a specified target; it cannot reconstruct target identity that the prompt never provides. This is a scope boundary of single-point prompting, not a claim that CBA resolves semantic ambiguity.
The submission already contains a prompt-necessity control consistent with this distinction. With the trained CBA fixed, the correct point gives Dice 0.756, while moving the point to a different target in the same image reduces Dice to 0.241 and removing the point reduces it to 0.093. CBA therefore remains target-conditioned rather than producing an image-level anatomy prior.
We additionally define an ambiguous click as a point contained in at least two annotated target masks in the same image, covering nested CAMUS structures and other overlapping annotations. A targeted evaluation gives:
The single-point repair is weaker on intrinsically ambiguous cases, as expected, but does not collapse: CBA still closes 0.820 of the available gap. Once one disambiguating click identifies the intended structure, gap closure rises to 0.889–0.912. This separates routing failure, which CBA repairs, from prompt underdetermination, which requires additional information.
Weakness 2 & Question 2. Multiple-Point Prompts
No architectural extension is required. CBA operates after prompt fusion on the fixed-size 64 × 64 × 256 image-stream activation, so its input shape is independent of whether the prompt encoder receives one point, three positive points, or positive and negative points. Variable-cardinality prompts therefore use the same 8,976-parameter module.
The base-model prompt sweep already shows that adding clicks alone does not remove the failure. Pair-weighted Dice calculated from Appendix Table 18 is 0.186 for three positive points, 0.179 for three positive and one negative point, and 0.097 for the default positive-negative pair, compared with 0.875 for the box reference. We evaluated CBA under the same prompt variants:
CBA therefore remains effective beyond the single-click setting. Mixed-cardinality training gives the strongest result without changing the module size or the frozen SAM backbone. The extension concerns only the prompt distribution used during training.
Weakness 3 & Question 3. Object Type, Size, and Shape
The dataset-level results already show that CBA is not specific to CAMUS. Gap closure computed from Table 2 is 0.854 on FLARE22, 0.938 on CAMUS, 0.957 on Kvasir-SEG, 0.871 on MSD Hippocampus, and 0.904 on MSD Prostate. This covers large abdominal organs, nested cardiac structures, irregular polyps, and small MRI targets.
We further stratified the held-out pool by target-area quartiles within each dataset, avoiding confounding from modality-specific image resolution. Shape irregularity is measured using compactness P²/(4πA), also normalized within dataset. The following are pair-weighted results; the four size rows reproduce the overall Point, CBA, and Box Dice after averaging:
Across size quartiles, CBA closes 0.871–0.905 of the gap. Performance is lowest for the smallest and most irregular targets, but the identified repair remains effective in both regimes. On FLARE22, per-organ gap closure ranges from 0.79 to 0.93; the lowest values occur for the adrenal glands and pancreas, while liver and spleen are highest. We will add the complete 13-organ table to our revised appendix. On CAMUS, gap closure is 0.94 for left-ventricular endocardium, 0.89 for left-ventricular epicardium, and 0.93 for the left atrium. These variations are consistent with the remaining difficulty being extent and boundary inference rather than failure of the localized route itself.
4. Learning Curve and Deployment Data Requirement
We trained CBA on stratified subsets of the 3,190-pair training pool, using the same held-out test set and three seeds at every fraction:
The curve improves monotonically and begins to saturate after 50% of the training pool. With 1,595 pairs, CBA already recovers 95% of the full-data Dice improvement over the native point baseline; increasing the set from 75% to 100% adds only 0.013 Dice. The full-data configuration still trains only 8,976 parameters, keeps the SAM-family backbone frozen, and takes approximately 18 minutes on one A100-80GB.