- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 1
- Quality
- 2
- Significance
- 2
Read review
Summary
This paper targets the practically important problem of grounding natural language into pixel-level segmentation in medical imaging. RADAR is technically coherent, carefully implemented, and its parameter efficiency result is genuinely noteworthy. The internal ablations are conducted with reasonable care across multiple configurations. However, the core contributions are incremental extensions of well-established mechanisms rather than conceptually new ideas. The experimental comparison has meaningful gaps in baseline coverage and dataset diversity, and the performance gains from the full system over simpler cascade alternatives are modest. Together these issues make it difficult to argue the work advances the field in proportion to the complexity introduced. The paper represents solid engineering work, but novelty and empirical validation fall short of the bar required for acceptance at this venue.
Strengths and weaknesses
Strengths:
The figures are generally well-produced and visually clean. Figure 3 in particular is well-organized, with the color-coded true positive, false negative, and false positive overlay scheme making cross-method qualitative comparison straightforward and interpretable at a glance.
Achieving competitive performance with only 0.74M trainable parameters while keeping both BiomedCLIP and MedSAM2 fully frozen is a practically meaningful result. Compared to V-L+S baselines like DIT (103.38M) and LGA (97.91M), the parameter gap is substantial and the efficiency argument holds up regardless of the novelty concerns.
Tables 2, 3, 4, and 6 provide a reasonably comprehensive internal analysis covering component contributions, backbone generalization, GRDA fusion variants, and LoRA injection ranges. The fact that GRDA and SDRA are tested across multiple backbone combinations in Table 3 is a good practice that strengthens the claim of general applicability of the two modules beyond the specific RADAR configuration.
Weaknesses:
The introduction identifies two bottlenecks (delayed semantic injection and lack of local discriminability) but the transition from problem motivation to proposed solution feels abrupt. The narrative jumps between VLMs, SAM, and contrastive learning without a clear unifying thread, making it harder to follow the logical progression toward RADAR's design choices.
While each proposed component is technically sound, the overall framework reads more as a careful integration of existing techniques than a conceptually novel contribution. GRDA, SDRA, and MPG each have clear and close predecessors in the literature, and the paper does not offer a principled theoretical account of why this particular combination generalizes beyond the empirical gains observed on three datasets.
Figure 1 occupies substantial page space yet largely restates content already covered in the introduction and later formalized in Figure 2. The three-panel layout (challenge, limitations, solution) could be condensed into a compact schematic, freeing space for more informative experimental content or architectural detail.
The captions throughout the paper, particularly for Figures 2 and 3, are minimal and largely descriptive of what is already visually apparent. A good caption should convey the key takeaway independently of the main text, for example explaining what the qualitative differences in Figure 3 demonstrate about each method's failure modes.
The motivation around delayed text-visual fusion as a core bottleneck has been substantially addressed in prior work, including [1] and [2] among others. The paper does not sufficiently situate GRDA with respect to these efforts or articulate what fundamentally distinguishes its semantic injection mechanism beyond the addition of a text-guided weighting term.
Several directly comparable VLM-SAM methods cited in the related work, including MedCLIP-SAMv2, TGSAM-2, and SegMoTE, are absent from Table 1 without justification, and stronger architectural baselines such as Swin-UNETR are not included. Furthermore, the ablation in Table 2 reveals that the simplest cascade baseline already captures most of the performance gain, with the full RADAR machinery yielding only incremental improvements that may not justify the added architectural complexity.
MPG relies entirely on handcrafted operations including quantile thresholding, morphological erosion, and dilation for point and mask prompt generation. The authors acknowledge this as a limitation but it also directly undermines the claim of a learned, generalizable framework, particularly for complex or low-contrast lesions where these heuristics are most likely to fail.
[1] Sultan, Rafi Ibn, et al. "Bipvl-seg: Bidirectional progressive vision-language fusion with global-local alignment for medical image segmentation." arXiv preprint arXiv:2503.23534 (2025).
[2] Cho, Yubin, Hyunwoo Yu, and Suk-Ju Kang. "Cross-aware early fusion with stage-divided vision and language transformer encoders for referring image segmentation." IEEE Transactions on Multimedia 26 (2023): 5823-5833.
Questions
MedCLIP-SAMv2, TGSAM-2, and SegMoTE are all directly comparable VLM-SAM cascades cited in your related work but absent from Table 1. Can the authors provide results for these methods under the same data splits and training protocol? If computational constraints prevented this, at minimum a discussion of how RADAR compares conceptually to these methods is needed.
Table 2 shows that the simplest BiomedCLIP-SAM2 cascade without GRDA or SDRA already achieves 90.02 Dice on Kvasir, while the full RADAR reaches 92.15. Can the authors clarify what the computational and architectural cost of the added components is relative to this 2-point gain? Specifically, does the added complexity of GRDA and SDRA translate to consistent improvements across all datasets and metrics, or are the gains dataset-dependent? A clearer efficiency-performance tradeoff analysis would strengthen the justification for the full system.
The evaluation is limited to two 2D chest infection datasets and one polyp dataset, which share relatively similar imaging characteristics. The conclusion mentions extensions to 3D and multi-class settings as future work. Can the authors provide even preliminary evidence, on a single 3D dataset or a modality outside chest and colonoscopy, that RADAR's design choices generalize? Without this, the scope of the empirical claims feels narrow relative to the generality implied by the framework's design.
Limitations
yes.
Paper formatting concerns
No concerns.
Final justification
The authors substantively addressed my experimental concerns during the rebuttal. They added the missing directly comparable VLM-SAM baselines under a matched protocol, reported multi-seed variance, provided a learnable prompt-generation comparison showing the handcrafted MPG is a defensible trade-off, and extended evaluation to a new modality via ISIC 2018 dermoscopy. They also corrected my misreading of the cascade result, showing the full modules contribute beyond the bare backbone. My main outstanding concern is the conceptual novelty, which the authors situate more clearly through per-module mechanistic distinctions but cannot fully resolve within a rebuttal, along with the presentation issues that are deferred to revision. Weighing the strengthened empirical validation against these points, I am raising my rating, while noting that novelty and presentation clarity remain the paper's soft spots and would benefit from the promised manuscript revisions.
We thank the reviewer for the detailed evaluation. We added direct VLM-SAM baselines, learnable prompt generation, efficiency, multi-seed evaluation, and dermoscopic attribute segmentation.
1. Novelty and integration concern
Layer aggregation, crop-to-dense alignment, VLM-SAM cascades, and LoRA have precedents. RADAR instead defines a semantic-to-spatial pathway with a clear functional progression. BiomedCLIP anchors semantics and MedSAM2 decodes masks, leaving two bottlenecks: historical-feature selection and target-boundary-context discrimination.
GRDA uses text-conditioned, spatially resolved depth routing rather than modality-agnostic weights or repeated early-fusion cross-attention. SDRA uses target-boundary-context regions and boundary-negative rejection rather than generic crop matching. MPG is an interpretable SAM-compatible prompt interface. They therefore follow consecutive needs--semantic retention, local discrimination, and prompt generation. We will revise the Introduction/Related Work and compare them directly with modality-agnostic aggregation, early-fusion methods, BiPVL-Seg, CLIPSelf, and related prompt pipelines.
2. Missing direct baselines
We added MedCLIP-SAMv2, TGSAM-2, and SegMoTE using the same splits, image-text samples, preprocessing, and evaluation code. All methods use seeds 42, 1, 2, 3, and 4; results are five-run mean±standard deviation.
RADAR leads these baselines on all metrics. MedCLIP-SAMv2 uses a response--pseudo-label--nnUNet pipeline, so localization errors propagate on diffuse MosMedData+ lesions. TGSAM-2 emphasizes tracking memory; SegMoTE emphasizes expert tokens, token-level MoE, and progressive prompt tokenization.
Swin-UNETR is designed for native 3D CT/MRI volumes, whereas our protocol uses native 2D images or independent 2D slices with image-level text. Pseudo-volume stacking or a 2D rewrite would change its task definition, and it has no text interface. We therefore retain the protocol-matched Swin-UNet baseline and will explain this explicitly.
3. The 90.02 result and performance-complexity trade-off
The cited 90.02 Kvasir Dice is the Table 3 Full configuration containing GRDA and SDRA, not a simple cascade. The actual w/o both result is 88.91. We will rename it RADAR-BiomedCLIP-SAM2.
For the final BiomedCLIP-MedSAM2 backbone, Full MPG already includes Text, Point, and Mask Prompts but excludes GRDA, Dense Modification, and SDRA:
Thus, even after a strong composite-prompt cascade, the representation path provides non-trivial further gains, especially on low-contrast, boundary-ambiguous MosMedData+. The gain is smaller on visually salient Kvasir targets. Improvements are consistent across backbones, although their magnitude is dataset/model dependent:
4. Practical cost
RADAR adds no large encoder/decoder. GRDA performs lightweight depth scoring/aggregation; Dense Modification reuses the final ViT Value features; the SDRA teacher and losses are training-only.
RADAR reduces task-specific trainable parameters by 98.15%-99.61% and the task checkpoint to 8.69 MB. Its FLOPs and speed are moderate rather than minimal, so we will claim task-adaptation/storage efficiency with moderate end-to-end computation.
5. Handcrafted MPG and learnable alternatives
We kept all other components/settings fixed and compared direct similarity-map prompts, global extrema points, and a learnable three-layer prompt head. RADAR-LMPG predicts a Mask Prompt and positive/negative heatmaps; spatial softmax and differentiable soft-argmax produce point coordinates.
Direct maps/extrema are less reliable because raw responses contain false activations and uncertain edges. RADAR-LMPG is viable, but increases trainable parameters from 0.74 M to 0.91 M (+22.97%) and is less balanced across datasets and boundary metrics.
6. Dataset diversity
We added ISIC 2018 Task 2 with five fine-grained dermoscopic attributes. These targets are small, sparse, disconnected, irregular, and visually similar. We use only
The dermoscopic image contains {attribute_name}.without GT-derived spatial information.RADAR leads all four segmentation metrics, improving over RecLMIS by 1.87 Dice/1.46 mIoU and reducing HD95/ASSD by 3.94/0.81. This extends modality and target morphology; native 3D, multi-organ, and multiclass validation remain limitations.
7. Presentation revisions
We will: (1) rewrite the Introduction as task gap → complementary foundations → two bottlenecks → decoupled framework → GRDA-SDRA-MPG progression; (2) simplify Figure 1; (3) separate inference and training-only paths in Figure 2 and clarify sparse/dense prompts; (4) expand Figure 3 captions to explain modality, difficulty, TP/FN/FP colors, and failure modes; and (5) rename BiomedCLIP-SAM2 Full as RADAR-BiomedCLIP-SAM2 and use Trainable Parameters consistently.