- Rating
- 2
- Clarity
- 3
- Confidence
- 5
- Originality
- 2
- Quality
- 2
- Significance
- 2
Read review
Summary
The authors propose Fractal-G, a plug-and-play module for Grid-Graph-Grid conversion that can be integrated into different segmentation network architectures, e.g., U-Net, Swin-UNet, and TransUNet. The method aims to improve specifically the boundary precision of segmentations, which is evaluated by Dice and Hausdorff Distance. The main experiments are performed on two datasets ISIC 2017 and Kvasir-SEG. Additionally, ablations on cross-resolution robustness and generalization to different datasets (CVC-ClinicDB) were performed.
Strengths and weaknesses
Strengths:
The problem of handling different resolutions and image dimensions is a relevant and interesting task. The idea of having a plug-and-play module that fits different architectures is a potentially impactful improvement for segmentation models.
Weaknesses:
Experiment Design:
The authors note conflicting information about the training epochs used for their experiments, noting 100 epochs twice in “B Experimental and Reproducibility Details”, and 200 epochs in “4.2 Implementation Details”. Combined with heavy augmentation, I am very concerned that 100 epochs and probably also not 200 epochs will not suffice to properly train the segmentation network. Given this setup, the experiments do not provide any conclusive evidence on which method is superior in achieving the highest possible performance. Moreover, I would encourage a decent hyperparameter sweep for the different methods to have a decent shot at high performance. Without cross-validation, hyperparameter sweeps, and limited training epochs, the evidence of higher performance, which is the fundamental claim of the paper, stays highly questionable.
The qualitative figures (Figure 3) are again raising concerns about the experimental setup. The failing patterns of the U-net segmentation tasks look very atypical for a well-trained U-net. The boundary also suggests that even at the native resolution of 256x256, the boundaries are not smooth.
How was nn-Unet trained? Are you using the setup described by nn-Unet (i.e. 1000 epochs)? How about losses and augmentations? Do you follow the nn-Unet paper or your described settings?
Showing a general-purpose plugin that consistently improves performance compared to U-net, nn-Unet alone is an extremely impactful claim. To properly support such a claim, I would expect a more thorough evaluation (see concerns listed before) and also experiments on more than 2 datasets (see Table 1).
Cross-resolution experiments:
These experiments should include the most trivial approach: upsampling/downsampling the segmentation mask to the desired resolution and using the resolution the model was natively trained on. This alone would reframe the ``grid-based baselines (e.g., U-Net) suffer catastrophic degradation´´ framing.
The full promise of improved segmentation quality rests on experiments that lack the methodological rigor to clearly demonstrate the method's benefit. I encourage the authors to do a thorough evaluation – broadly evaluating strengths and weaknesses -, which ultimately will also help the deployment of the method.
Questions
-> Can you provide the validation curves for all models to show that after 100/200 epochs, the validation performance has plateaued?
-> Did the nn-Unet baseline actually use the nn-Unet settings (i.e., 1000 epochs training)?
-> Can you add the input image to Figure 4? It is very hard to interpret the results without being able to see the object that should be segmented.
-> Figure 6 references results on DRIVE, where are they?
Limitations
yes
Paper formatting concerns
Final justification
The absolute lack of comparison to the related literature - no mentioning and no comparison - in the medical image segmentation community prompts me to raise my confidence to 5 and maintain my rating to 2. The mult-scale training is a year-old remedy to the problem described by the authors, applied in dozens of papers with thousands of citations. Acting, as all of this does not exist, is a concerning violation of scientific standards.
Response to Reviewer FAji (Submission 5141, Fractal-G)
Thank you for your time. All concerns are addressed below (Weaknesses/Questions as W/Q); this response provides:
W1 & Q1: Inconsistent training epochs (Sec. 4.2 vs. Appendix B.2); validation curves
Correction. We apologize for the inconsistency, which stemmed from drafting errors in both Sec. 4.2 and Appendix B.2 (weight decay and batch size were incorrectly stated in Sec. 4.2, while Appendix B.2 listed inconsistent epoch/schedule details). The correct and unified protocol for all models is:
AdamW optimizer, initial lr 1×10−4, weight decay 1×10−5, cosine-annealing schedule with 5-epoch warmup, 200 epochs, batch size 16, identical augmentation pipeline, and best-validation-Dice checkpoint selection. Both Sec. 4.2 and Appendix B.2 will be corrected in the revision.
Convergence evidence (Q1). Validation-Dice curves of all models plateau before epoch 200 (Table 1), so the reported rankings are not an artifact of under-training.
Table 1. Validation Dice at key epochs (all models, both datasets).
W2: Hyperparameter sweeps and fairness of comparison
We clarify: (i) all methods share one protocol (W1 & Q1), mirroring nnU-Net's controlled-ablation philosophy [3]; (ii) our claim rests on paired backbones ± Fractal-G (Table 2), which shows +4.79 Dice and -13.32 HD95 on Kvasir-SEG.
We now provide sensitivity analyses for the design choices singled out by the AC and reviewers (all on Kvasir-SEG, U-Net + Fractal-G):
Table 2. Sensitivity of Fractal-G to its fixed design choices (Kvasir-SEG).
Excluding the structural patch scale P (chosen to match the encoder stride ratio), the remaining choices are insensitive: Dice varies by at most 2.5 points for τ∈[0.3,0.7] and K≥4, and HD95 changes smoothly with K — no performance cliff.
W3: "Atypical" failure patterns of U-Net in Fig. 3
The U-Net baseline is converged (W1 & Q1), so the qualitative behavior in Fig. 3 is not caused by under-training. Fig. 3 shows the cross-resolution stress test (256-trained model evaluated directly at 128/512). The jagged native boundaries motivate our work: discrete upsampling creates staircase artifacts that Dice misses but HD95 captures (U-Net 17.70 px vs. ours 9.88 px). We will clarify the caption.
W4 & Q2: How was nnU-Net trained?
In the submission, "nnU-Net" denotes the nnU-Net backbone re-implemented under our protocol (W1 & Q1), not the full self-configuring pipeline [3]; we apologize for the ambiguity. We now additionally report the official nnU-Net (1000 epochs, its own augmentation/loss):
Table 3. Official nnU-Net pipeline vs. our method.
W5 & Q4: Experiments on more than two datasets; the DRIVE reference in Fig. 6
First, a correction: the DRIVE mention in Fig. 6's caption was a drafting error — the figure contains only ISIC/Kvasir rows; we will correct the caption.
We add experiments on DRIVE (retinal vessels, 20/20 train/test), reporting clDice [1] (skeleton connectivity), the topology metric used in TopCoW [2]:
Table 4. Results on DRIVE (all methods under identical protocol).
Fractal-G improves its backbone on all three metrics, with the largest gain on clDice (+0.27, 0.57 vs. 0.30).
W6: The trivial resize baseline for cross-resolution experiments
We add this baseline: train at 2562, test by resizing input to 2562 and the prediction back:
Table 5. Cross-resolution evaluation with the resize-to-native baseline (Kvasir-SEG).
Resize recovers part of U-Net's Dice, but boundary quality remains worse (U-Net+resize lags Fractal-G by 67.05 HD95 at 5122). Fractal-G needs no resolution-dependent pre/post-processing.
Q3: Input images in Fig. 4
Agreed — original images will be added to Figs. 3--5 in the revision.
R1 References
[1] Shit, Suprosanna, et al. "clDice-a Novel Topology-Preserving Loss Function for Tubular Structure Segmentation." 2021 IEEE Conference on Computer Vision and Pattern Recognition (CVPR). IEEE, 2021.
[2] Junayed, Md Shakib Shahariar, et al. "Topology-aware anatomical segmentation of the Circle of Willis: HUNet unveils the vascular network." IET Image Processing 18.10 (2024): 2745-2753.
We hope the revised paper meets your expectations. Glad to provide further responses if needed.