- Rating
- 4
- Clarity
- 2
- Confidence
- 4
- Originality
- 2
- Quality
- 2
- Significance
- 2
Read review
Summary
This paper proposes TRiST, a Swin-based architecture family for medical image classification and segmentation. It constructs persistent-homology descriptors at four native Swin stages instead of downsampling a single topology representation. It further refines H0/H1 descriptors using persistence-band-specific residual MLPs and converts selected bands into an additive attention bias. The framework is instantiated as Topo-SwinV2-B for classification and Topo-Swin-UNet for segmentation. Experiments on ISIC 2018, CBIS-DDSM, RetinaMNIST, Synapse, and ACDC report improvements over Swin-based baselines and competitive performance against several topology-augmented or segmentation baselines.
Strengths and weaknesses
Strengths:
- The paper targets a relevant gap: most medical image Transformer models do not explicitly represent topological structures such as connected components and loops. This motivation is reasonable for tasks involving lesions, boundaries, vessels, and organ shapes.
- The method description is mostly readable at a high level. The three main components are clearly separated and the overall pipeline is easy to follow.
- The paper evaluates both classification and segmentation. This is valuable because it tests whether the topology pathway can help both image-level and dense prediction tasks.
Weaknesses:
- The paper’s core motivation assumes that key medical image signals are “topological” rather than primarily anatomical, statistical, or semantic. This is asserted through examples, but the paper does not establish that persistent homology is the right abstraction for these signals. The clinical motivation feels retrofitted to the method. Microaneurysms, lesion boundaries, myocardium rings, and calcification clusters are mentioned as topology-like objects, but the paper does not show that the proposed descriptors actually isolate these structures.
- The problem formulation is too broad. “Medical image analysis” covers very different modalities, tasks, resolutions, and clinical endpoints, but the proposed research problem treats them as if one topology mechanism should naturally apply to all. The paper uses strong clinical language but remains methodologically generic. It does not define a clinical decision problem where preserving topology is necessary, nor does it connect the model output to clinical utility.
- The novelty is overstated relative to prior topology-feature and topology-attention work. The paper mostly combines known ingredients, like PH descriptors, band processing, and attention bias, inside Swin. The paper turns an implementation choice into a conceptual contribution. Aligning topology descriptors to Swin stages is reasonable engineering, but the paper does not make a convincing case that this defines a new research direction.
- The method lacks a convincing mechanistic demonstration that the PH descriptors capture clinically meaningful topology rather than intensity-driven local texture. The medical interpretation is asserted more strongly than it is validated.
- The attention-bias formulation is weaker than advertised. Because the query-side term cancels under softmax, the effective mechanism is a key-saliency prior rather than a genuine pairwise topological interaction.
- The method is tied to 224-style resized 2D images and does not account for physical pixel spacing. In medical imaging, topology at a fixed pixel scale may not correspond to anatomy at a fixed physical scale.
- The method discards color information by converting RGB crops to grayscale before PH computation. This is questionable for dermoscopy and retinal tasks where color cues can be diagnostically important. The crop-level max-normalization may distort clinically relevant intensity information. The paper does not analyze how sensitive PH descriptors are to this preprocessing.
- The empirical gains are often modest. Several improvements are small relative to the reported standard deviations, and no statistical testing is provided.
- The paper frames the method as broadly competitive, but the strongest baselines are not consistently beaten. The narrative is more positive than the tables justify. For example: The segmentation comparison is not fully favorable to the proposed method. On Synapse, stronger 3D methods still substantially outperform the proposed 2D model in Dice.
- The method does not address volumetric topology despite using CT and MRI datasets. The 2D slice formulation may miss exactly the 3D anatomical structures the motivation emphasizes.
Questions
- What evidence shows that the relevant failure mode of Swin/Swin-UNet is specifically topological?
- Can the authors demonstrate that the PH descriptors correspond to clinically meaningful structures rather than intensity artifacts or generic texture? Visualizing topology maps, learned gates, and attention changes would help clarify this point.
- Why should topology be computed from raw grayscale input patches rather than learned features, masks, edges, or morphology-aware representations? This question is central because the medical motivation depends on the descriptors capturing anatomy rather than preprocessing-dependent image patterns.
- How should the proposed pixel-scale topology be interpreted across datasets with different physical resolutions and modalities? My evaluation would improve if the authors account for physical spacing or show that the method is robust to scale and resolution changes.
Limitations
The paper mentions offline topology precomputation and the lack of native 3D topology, but the limitations discussion is incomplete. It should also discuss whether 2D patch-level PH is an adequate proxy for 3D anatomy, how resizing and pixel spacing affect topological descriptors, how grayscale conversion and normalization influence PH, whether high-persistence features can reflect artifacts, what storage and deployment overheads are introduced, and when topology is expected not to help.
Paper formatting concerns
No
Final justification
The rebuttal solved most of my questions, so I improved my score.
We sincerely thank the reviewer for the detailed feedback. We agree that the paper would benefit from stronger mechanistic interpretation, clearer discussion of physical scale and preprocessing, direct topology visualization, and formal statistical testing. Below, we address the questions and weaknesses raised.
Q1. What evidence shows that the relevant Swin failure mode is specifically topological?
We do not claim that every Swin or Swin-UNet error is caused by missing topology.
Our narrower claim is that standard Swin representations do not explicitly encode persistent connectedness and enclosure, and that these descriptors provide complementary structural information.
The evidence includes matched-backbone improvements across five datasets and ablations comparing native stage-wise PH with Stage-1-only and downsampled topology, logit-level injection with feature concatenation and residual gating, and progressive with uniform band routing.
These results support the value of stage-aligned PH and the proposed integration mechanism, but do not prove that all baseline errors are topological. They also do not constitute a parameter-matched randomized-topology control.
Our contribution is therefore an architectural solution for reinforcing a hierarchical Transformer with native multi-scale, token-aligned persistent topology.
Q2. Can the authors show that PH corresponds to clinically meaningful structures rather than intensity artifacts or generic texture?
The paper establishes predictive utility and representational effects more directly than complete mechanistic or clinical attribution.
The PH branch computes H0 and H1 from max-normalized grayscale sublevel sets. The descriptors therefore represent persistent connected components and loops in relative grayscale-level structure. They are computed without semantic labels, masks, expert annotations, physical intensity units, or clinical outcome definitions.
The clinical examples in the Introduction motivate why connectedness and enclosure may be relevant, but do not imply that every persistence feature has a one-to-one correspondence with a clinically annotated structure.
Evidence includes matched-backbone gains, topology-refinement and injection ablations, native-versus-downsampled topology, persistence-band ablations, qualitative segmentation results, and Appendix Figure 3.
Figure 3 shows that Topo-SwinV2-B learns discriminative activation patterns that differ from those of the matched SwinV2-B backbone. This supports the conclusion that the topology pathway affects hierarchical representation learning rather than serving only as an auxiliary classifier-level feature.
However, GradCAM visualizes discriminative activations, not PH generators, topology-score maps, or clinical annotations. It therefore supports a representational effect but not one-to-one clinical attribution.
The segmentation examples provide complementary evidence because fragmentation, missed components, and boundary discontinuities are related to connectedness and enclosure. However, these examples remain qualitative. They show that the topology pathway can affect structurally relevant prediction behavior, but do not establish that every corrected region is caused by a specific persistence generator.
We do not claim prospective clinical validity or one-to-one clinical attribution. Direct comparison of topology-score maps or persistence generators with expert annotations would be required for such a stronger conclusion.
Q3. Why compute topology from raw grayscale patches rather than learned features, masks, edges, or morphology-aware representations?
We use raw-input topology for four reasons:
We do not claim that raw grayscale PH is universally optimal. Edge-based, learned-feature, color-space, and multi-filtration alternatives are meaningful future directions.
This work evaluates one mathematically specified and supervision-independent design.
Q4. How should pixel-scale topology be interpreted across datasets with different physical resolutions and modalities?
The supports 32, 64, 128, and 192 pixels are defined relative to the standardized 224×224 input.
They represent relative spatial contexts aligned with the four Swin stages, not fixed physical anatomical sizes.
Standardized resizing provides some robustness to differences in native acquisition dimensions.
Consistent gains across dermoscopy, mammography, retinal imaging, CT, and MRI suggest that the framework is not tied to one modality or native resolution.
The native multi-scale ablation further shows that stage-specific PH is more effective than Stage-1-only or downsampled topology.
However, this does not establish physical-spacing invariance.
A fixed pixel support may correspond to different anatomical sizes, and the paper does not include controlled rescaling experiments.
With reliable metadata, future work could define supports in millimeters or resample images to a common in-plane spacing.
Thus, we claim robustness across standardized heterogeneous datasets, not physical-scale invariance.
W1. The clinical motivation is asserted or retrofitted
We respectfully disagree with the implication that the paper assumes medical-image information is topological rather than anatomical, semantic, statistical, or photometric.
Our hypothesis is complementary rather than substitutive. The Swin pathway continues to learn appearance, color, texture, semantic, and anatomical representations from the full image, while PH contributes explicit descriptors of connectedness and enclosure.
The use of multiple modalities and tasks evaluates whether the architectural mechanism transfers across heterogeneous settings. It does not imply that every clinical endpoint shares the same topology or that PH alone is sufficient for medical decision-making.
The paper evaluates benchmark classification and segmentation performance. It does not claim prospective clinical utility, which would require task-specific expert validation and clinical studies beyond the scope of the current representation-learning work.
W2. The novelty is overstated
We agree that several individual ingredients are established.
Our contribution is their specific architectural integration.
The question we address is:
TRiST computes PH independently at four native Swin supports, aligns descriptors one-to-one with stage token grids, separately processes H0, H1, and persistence bands, predicts per-token/per-head topology scores, injects them into pre-softmax attention logits, and applies the same framework to classification and segmentation.
The ablations show that single-scale and downsampled topology are weaker, feature concatenation and residual gating are weaker than logit-level injection, and uniform routing is weaker than progressive routing.
The novelty is therefore architectural and empirical, not based on claiming that every primitive is independently new.
The work may motivate further study of structural priors—such as topology, geometry, and anatomy—in modern neural architectures. However, this paper validates the approach specifically in Swin-based classification and segmentation. Extensions to CNN-, Mamba-, or other architecture families remain future work and are not claimed as demonstrated contributions.
W3. The attention formulation is key-centric rather than query-centric
Please refer to our response to Reviewer NrRe regarding Weakness 6 (W6).
W4. Grayscale conversion may discard important color information
Grayscale conversion affects only the PH branch; the Swin backbone still receives the original RGB image.
Thus, grayscale PH is a structural complement to the RGB representation, not a complete model of color topology. Channel-specific or multi-filtration PH is a meaningful extension.
W5. Crop normalization may distort clinically meaningful intensity information
The PH branch applies per-crop maximum normalization: I(x)=maxyI(y)I(x).
This standardizes the filtration range but removes the absolute intensity scale. Persistence therefore represents relative within-crop intensity patterns rather than absolute CT, MRI, mammographic, or radiographic units.
Because normalization is crop-specific, the same normalized threshold may correspond to different absolute intensities across token locations. This improves robustness to local intensity and exposure variation but sacrifices a globally consistent filtration scale.
This is an interpretive limitation, but it does not invalidate matched comparisons using the same standardized inputs.
W6. The gains are modest
Please refer to our response to Reviewer NrRe regarding Weakness 1 (W1).
W7. Stronger 3D models outperform TRiST
Please refer to our response to Reviewer NrRe regarding Weakness 3 (W3).
W8. No native volumetric topology
Please refer to our response to Reviewer NrRe regarding Weakness 5 (W5).