Read review
Summary
The authors propose CycleSpectra to reconstruct the full cardiac cycle of motion from sparsely observed cardiac images for dynamic cardiac function assessment. The key idea is to learn the spectral structure of the cardiac motion, i.e., the frequency coefficients of the deformation field, from given images. The cardiac motion at a query phase is first generated through a fixed analytic synthesis layer where the query phase is input as a query coordinate and then refined through a neural network decoder. The proposed method was validated on a thin slice 4D cardiac CT dataset and a 4D cardiac MRI dataset. The results show that it can outperform baseline methods for 4D cardiac motion modeling.
Strengths and weaknesses
Strengths:
- The proposed method can learn the spectral structure of cardiac motion from sparsely sampled cardiac images and further refine high frequency motion components.
- The proposed method can improve 4D cardiac motion modeling given very sparse cardiac image observations.
Weaknesses:
- Although the authors claimed that they were making use of the cyclic physical property of cardiac motion, the proposed method was not applied to cyclic cardiac motion modeling given that only one cardiac cycle was considered. To me, the analytic phase synthesis layer (Eq. (2)) looks like a Fourier transformation of the cardiac deformation field. Thus, the key contribution is to use two cardiac image frames to predict the Fourier coefficients which can synthesize the cardiac motion in a full cardiac cycle. I think the novelty of the proposed method is not high.
- In Eq. (2), only the anchor phase is considered. Why not include the context phase into Eq. (2)? Since the context image frame is also an input to the network, it may be helpful to include the context phase into Eq. (2) to improve the full cardiac cycle motion estimation performance.
- The usage of the context phase frame can be further enhanced. One way is to predict the motion field between the context phase frame and the query frame such that you can warp the context frame towards the query frame. You can compose the two motion fields as the third one which warps the anchor towards the context.
- The in-house 4D cardiac CT cohort only contains 36 subjects. For a learning-based method, the dataset is too small for training, validation and testing.
- It remains unclear that how did the authors evaluate the Curve corr? Did you segment each frame in the 4D CT?
- The performance of the proposed method on canonical ED/ES protocol is not strong as indicated by the Curve corr.
Questions
- Is only one cardiac cycle considered? If so, how to make use of the cyclic physical property of cardiac motion?
- In Eq. (2), only the anchor phase is considered. Why not include the context phase into Eq. (2)?
- How did the authors evaluate the Curve corr? Did you segment each frame in the 4D CT?
Limitations
- The proposed method was not applied to cyclic cardiac motion modeling given that only one cardiac cycle was considered. To me, the analytic phase synthesis layer (Eq. (2)) looks like a Fourier transformation of the cardiac deformation field. Thus, the key contribution is to use two cardiac image frames to predict the Fourier coefficients which can synthesize the cardiac motion in a full cardiac cycle. I think the novelty of the proposed method is not high.
- The usage of the context phase frame can be further enhanced. One way is to predict the motion field between the context phase frame and the query frame such that you can warp the context frame towards the query frame. You can compose the two motion fields as the third one which warps the anchor towards the context.
- The in-house 4D cardiac CT cohort only contains 36 subjects. For a learning-based method, the dataset is too small for training, validation and testing.
- The performance of the proposed method on canonical ED/ES protocol is not strong as indicated by the Curve corr.
Paper formatting concerns
None
Final justification
I thank the authors for the detailed rebuttal. They have partially addressed my concerns. So, I would like to raise my rating from 3 to 4. However, I do not think the contribution type is General, as the application is for 4D cardiac motion reconstruction. If it's General, why did not the authors include other 4D motion reconstruction applications (such as lung motion) into the work?
We thank the reviewer for recognizing that CycleSpectra improves full-cycle cardiac motion reconstruction from very sparse observations and for highlighting its learned spectral structure and high-frequency refinement. We believe the core concern—that Eq. (2) "looks like a Fourier transform"—rests on a misreading of what is actually computed at inference. We clarify this below and restate our actual contribution.
Re Weakness 1, Q1 & Limitation 1: One observed cycle, cyclicity, and originality.
On "one observed cycle." The reviewer is right that we model a single, representative cardiac cycle. This is deliberate, and what makes the modeling cyclic is structural rather than statistical. As framed in our Introduction, the cardiac cycle "is, by physical fact, ... a closed periodic process," and we take this cyclic structure "as the starting point of the representation rather than as a property the model needs to learn": the shared coefficient set is read out by a fixed analytic layer whose trajectory is periodic and closed by construction (ψ_q and ψ_q+1 yield the same deformation), so within one period the reconstructed motion returns onto itself. The cyclic property we exploit is therefore the within-cycle closure of a single beat, enforced by design rather than inferred from data. Phase-resolved 4D-CT densely spanning multiple cardiac cycles of the same subject is not available to us; we therefore did not design the method to exploit cross-cycle cyclicity, and we make use of the cyclic physical property only in the within-cycle, structural sense the data support.
On originality: the idea is common, but the design is the contribution. We agree that sinusoidal bases and "predicting frequency coefficients" are, in themselves, textbook; the contribution is not the basis but the design that makes such coefficients recoverable at all—a design another reviewer independently described as a novel and elegant one. A Fourier transform needs a densely sampled signal to transform, yet at inference we have no observed deformation sequence—only two CT volumes. Eq. (2) is merely the fixed read-out; the actual problem is the severely under-determined inverse one: recovering an entire per-voxel periodic displacement spectrum {A_k, B_k} from just two volumes. Two frames cannot determine this alone—what makes it well-posed is a 3D encoder that has learned, across the cohort, an amortized prior mapping the appearance correspondence of two sparse volumes to a subject-conditioned spectral motion field.
In fact, this design was reached deliberately. Early in the project we tried feeding multiple frames jointly, but the memory cost of dense 3D volumes caps the usable count very low—about four frames on a single RTX 4090—far too few to cover a full cycle; our data are also heterogeneous, with subjects differing in both the number of acquired phases and their sampling times, so a fixed multi-frame input grid is ill-suited. This led to the present framework: a fixed, small input set with a phase-queryable analytic read-out supervised across many phases.
Direct evidence. We isolate the basis's contribution with a strictly matched control (identical encoder, refinement, data, supervision, and schedule; only the motion representation changes). Replacing the shared Fourier-coefficient read-out with a strong sinusoidal phase-conditioned single-flow decoder leaves image fidelity unchanged (PSNR 22.76 vs. 23.13 dB; SSIM 0.814 vs. 0.820) but raises LVEF error from 8.0% to 19.7% (≈2.5×) and drops curve correlation from 0.871 to 0.743. Conditioning a free decoder on trigonometric encodings does not recover cyclic motion; enforcing a shared per-site spectrum on one analytic periodic trajectory does.
Re Weaknesses 2–3, Q2 & Limitation 2: The context phase, context-to-query flow, and flow composition.
We regret that our presentation caused this confusion. Using a single reference phase in each instance of Eq. (2) is a deliberate design choice: Eq. (2) synthesizes the deformation from a source configuration (at its reference phase) to the queried configuration (at ψ_q), and subtracting the basis state at the reference phase fixes the reference geometry and gives exactly zero displacement when ψ_q equals it. A second reference phase in the same read-out would either double-count the reference or break this zero-at-reference property, so we keep one source per directional call. The context still plays a central role: the context volume conditions the shared coefficient fields {A_k, B_k} through appearance correspondence in the encoder. We will make this explicit in the corresponding part of the revision to avoid the ambiguity.
We thank the reviewer for this suggestion. The context phase already enters the read-out through a deterministic bidirectional scheme, with no extra learnable weights. Each query is routed to the nearer observed endpoint: the forward arc uses the anchor as source, D(X_a, X_c, ψ_a, ψ_q), and the reverse arc uses the context as source, D(X_c, X_a, ψ_c, ψ_q), so the context phase enters the read-out directly through s(ψ_q) − s(ψ_c). This reverse-arc field is exactly the context-to-query flow suggested in Weakness 3: rather than estimating two independent fields and summing them into a third, both directions are read from one shared periodic spectrum, so the two frames are coupled by construction. An endpoint-closure consistency loss (λ_ep, defined in Appendix A.1.2) further ties the predicted query back to the held-out endpoint in image space; removing it lowers LV/RV curve correlation from 0.871 to 0.816. We will make this two-stage use of the context—coefficient conditioning in encoding, analytic source in the read-out—explicit in the revision, and surface the endpoint-closure term in the main text.
Re Q3 & W5: How the Curve correlation is computed.
We segment only the native 4D-CT frames once, and reuse those labels rather than re-segmenting each generated frame. The reference curve uses this frozen chamber segmentation at every native 4D-CT phase; for CycleSpectra, at each query phase the endpoint chamber label is warped by the predicted flow (nearest-neighbor). LV and RV voxel volumes are then measured at all non-input phases, Pearson correlation is computed separately for LV and RV and averaged per pair, and pairs are reduced within subject before the 7-subject summary. To confirm the ranking does not hinge on this warp-vs-segment choice, we additionally re-segment every method's generated CT with a single frozen no-TTA nnU-Net as an output-side control; this yields the same ranking and is detailed in our responses to 1SoJ Q1 and muhU Q2.
Re W6: Canonical ED/ES Curve correlation.
Canonical ED/ES is the privileged input pair: every baseline is built and tuned to interpolate between exactly these two extrema, so ED/ES is the setting most favorable to interpolation methods and the least discriminative for ours. We claim robustness to arbitrary two-frame inputs, which is what the opposite-pair protocol tests, and there CycleSpectra is clearly strongest (curve correlation 0.862, LVEF error 8.0%, over the 7 test subjects—after an audit correction detailed in our response to 1SoJ—while interpolation/per-pair baselines drop to ~0.1 correlation and >24% LVEF error). Since our advantage lies away from the ED/ES extrema, it is expected that we rank below the best on a few canonical-ED/ES metrics.
Re W4 & Limitation 3: Cohort size.
We agree 36 subjects (22/7/7) are modest, and we do not overstate the evidence: the 85 opposite pairs are nested within the same 7 test subjects—they broaden endpoint coverage, not the number of independent anatomies—so we report per-subject values with 10,000-resample subject-level bootstrap intervals rather than treating pairs as independent. Two factors mitigate the concern: the model is deliberately low-capacity where it matters (cardiac motion is genuinely low-frequency, K=1–2 already suffices), so it is not over-parameterized for the cohort; and we evaluate transfer without retraining on an external 4D-CT cohort and a cross-modality 4D-cMR set, probing acquisition and modality shift. We state this as a limitation, and leave larger multi-center and pathological validation to future work.