From Heartbeat to Cardiochoreography: A Mechanics Foundation Model for Individualized 4D Cardiac Motion Generation Conditioned on Electrophysiology

Ziquan Wei, Tingting Dan, Guorong Wu

Abstract

The electrocardiogram (ECG) is a time series that records the electrical activity driving cardiac motion through electromechanical coupling (EMC), where the depolarization captured by ECG triggers each heartbeat. The temporal delay and low spatial resolution of such multichannel dynamic data often cause temporal and spatial misalignments along the physical motion, limiting the application of ECG data to event/segment-based downstream clinic practice. Although many efforts have been made to recover spatiotemporal trajectories conditioned on ECG waveforms, the intrinsic principle of EMC that results in various temporal delays remains underexplored in current generative models. To address this limitation, we propose Time2Track, a mechanics foundation model that generates individualized 4D heart motion from same-day ECG recordings by encoding electrophysiology as delay-aware token embeddings. Specifically, a learnable wavelet decomposition extracts the electromechanical delay, which is then formulated as a physics-based conditioning signal for motion diffusion. Time2Track generates 4D motion with individual-specific kinematics, avoiding the collapse to a population average, i.e., a common failure scenario when diffusing motions whose inter-subject differences are subtle. On subjects from the UK Biobank, our Time2Track accurately synthesizes 4D cardiac trajectories from ECG and preserves inter-subject diversity, a regime in which generic motion diffusion baselines collapse to a population average.

Keywords:
Atlanta, Main Track

Reviews

Among:
Shape:
123456this paper, Bottom 17%
Figure 1. Mean review rating of the reviewed papers at NeurIPS 2026. This paper averages 4.00 over 3 reviews, above 17% of the others.
Reviewer_PhZAOpenReview ↗
Rating
5
Clarity
3
Confidence
3
Originality
4
Quality
3
Significance
4
Read review
Summary

The authors propose a method to generate the patient-specific 3D+T cardiac motion (a 3D mesh sequence derived from cardiac MRIs) given the patient’s resting-state ECG. For encoding the ECGs, the authors propose a electomechanical coupling (EMC) foundation model which explicitly embeds temporal delay and waveform morphology, addressing the challenge of varying temporal delays between channels. They integrate this into a conditional diffusion framework for generating the 3D+T cardiac motion sequences and evaluate it on ECG-to-motion prediction.

Strengths and weaknesses

Strengths

  • Well motivated and previously unsolved task

    The prediction of cardiac motion from ECGs alone enables continuous cardiac function monitoring using non-invasive methods, making this approach highly relevant. Additionally, this specific task has not yet been addressed before.

  • Design of the method informed by known and validated biomedical mechanisms.

    The authors consider known aspects about electromechanical coupling when designing their system. These aspects are empirically validated in their study and inspire the design of their delay tokenization method. Finally, they empirically confirm the benefit of this tokenization method.

  • Overall well-written and well-structured paper

Weaknesses

  1. Evaluation only on ECG to cardiac motion generation, while authors claim to contribute a general electomechanical coupling (EMC) model

    Throughout the paper the authors claim that they propose a general EMC model that is agnostic to electrophysiology type. While this claim may be true with respect to their method design, they never empirically validate this claim by evaluating it on another, non-ECG task. This lack of evaluation on other electrophysiology types may not be a major weakness in itself: there may simply not be a public dataset for other electrophysiology types and the contribution of the ECG-to-motion model is relevant on its own. However, then the claims should be phrased adequately (the authors may still highlight that their method design is agnostic to the electrophysiology type).

    To address this please discuss why the method was not evaluated on other electrophysiology types (e.g. lack of data) and adapt the claims accordingly.

  2. Choice of baselines and ablation studies could be better explained and motivated

    While there are no baselines for this specific task, the authors vary the electrophysiology encoder to validate their contribution. This evaluation approach seems legit, but the authors do not explicitly motivate their choices of the individual encoders. To address this concern the authors could:

    (a) Highlight the properties of the individual baseline encoders (comparing them with each other and the proposed encoder)

    (b) Motivate the choice of the specific encoder models, especially for the temporal transformer baseline: Based on which criteria (e.g. SOTA on a bechnmark) was it chosen. (see also questions)

    (c) Discuss how the encoder properties influence the empirical results and how that validates the authors’ contributions (this is already partially addressed but should be connected to the encoder properties)

    (d) Mention and summarize the ablation study results (currently in the appendix) in the main text and discuss how they validate the authors’ contributions.

    I highlight that there is not necessarily a baseline missing, but that the choice of baselines should be clearly motivated in the manuscript.

  3. (Minor) Presentation of the method

    While the paper is overall well-written and -structured (see strengths), the introduction of the method, especially the beginning of Sec. 3, is quite dense. Fig. 2 definitely helps with that. However, it might help to provide a high-level overview of the approach very early on. This overview may also specifically motivate the individual components, even though the general motivation is already given in the introduction. Such a component-level motivation could also be added to the Fig. 2 caption, which at the moment is purely descriptive. Overall, I don’t think that any notation or description is inappropriate, but an early motivating overview may help readers to quickly understand the individual aspects of the method.

Questions
  • Why was the model not evaluated in other electrophysiology types (i.e. non-ECG)?
  • Why did the authors specifically chose TeCh as their temporal transformer baseline, while there is a wide range of other temporal foundation models? Is it currently SOTA on some relevant benchmarks?
Limitations

yes

Paper formatting concerns

none

Final justification

The authors addressed all my points and, in my opinion, also the points of the other reviewers. Overall, I think this is a very good paper and should be accepted at NeurIPS, I therefore keep my score (5: Accept). Note that in my opinion, it does not reach the threshold for a Strong Accept (which is reserved for very high-impact papers), which is why I do not increase my score any further. This does, however, not invalidate the quality or relevance of the paper in any way.

1 comment

W1

To demonstrate the foundation nature of our delay tokenization method, we have run the experiments on the modality sEMG using EMG2POSE dataset. We cropped sEMG sessions to have only the first gesture, then we used vemg2pose [1] and EMGFormer [2] as the baseline to against delay-injected versions. The sEMG experiments are repeated with 3 different random seeds. As listed below, models injected with delay tokens mostly outperform baselines. In the complete val split (all) and the first 4 biggest subgroups of gesture stage, +delay has at least 3 out of 4 metrics been improved on the held-out test split.

[1] S Salter, "emg2pose" NIPS 2024

[2] Z Xi, “EgoEMG” arXiv 2026


Table (EMG2POSE exp)

Val subgroupmethodRMSE|PAR-1||APCR-1||APDR-1|
ALL (n=6,151)EMGFormer0.663±0.0030.483±0.0050.066±0.0050.019±0.002
+delay0.666±0.0030.469±0.0100.061±0.0050.020±0.001
vemg2pose0.530±0.0010.555±0.0040.088±0.0130.025±0.002
+delay0.529±0.0000.561±0.0030.076±0.0060.025±0.001
HandOverHandCountingUpDownFingerWigglingSpreading (n=843)EMGFormer0.748±0.0040.432±0.0020.059±0.0080.015±0.001
+delay0.750±0.0040.408±0.0120.039±0.0070.017±0.001
vemg2pose0.646±0.0020.466±0.0030.022±0.0120.018±0.001
+delay0.643±0.0030.478±0.0030.011±0.0100.018±0.001
ShakaVulcanPeace (n=710)EMGFormer0.777±0.0040.521±0.0090.023±0.0140.028±0.001
+delay0.786±0.0070.509±0.0170.015±0.0090.027±0.001
vemg2pose0.585±0.0020.613±0.0070.235±0.0180.038±0.004
+delay0.587±0.0030.617±0.0070.225±0.0020.038±0.001
HookEmHornsOKScissors (n=710)EMGFormer0.890±0.0040.356±0.0090.185±0.0070.032±0.001
+delay0.893±0.0030.338±0.0130.207±0.0080.031±0.001
vemg2pose0.562±0.0020.606±0.0050.156±0.0040.038±0.001
+delay0.561±0.0010.609±0.0060.139±0.0210.039±0.002
FingerFreeform (n=703)EMGFormer0.678±0.0050.387±0.0170.155±0.0150.019±0.000
+delay0.676±0.0040.357±0.0090.143±0.0050.018±0.001
vemg2pose0.616±0.0020.448±0.0030.092±0.0050.020±0.000
+delay0.614±0.0020.453±0.0030.097±0.0080.020±0.001

W2

(a) We use the encoder property table below to summarize our model and all other models under comparison.

(b) Column "Why included" gives the criterion for every encoder, and column "Time Lag" shows that the set sweeps every way of handling the delay.

(c) Against Table 1 in the paper, column "Params" is not sorted by performance, but column "Time Lag" is, where |APDR−1| is 0.151 and 0.170 with no lag, 0.079 with wavelet scales, and 0.019 with learned lag.

(d) We will brief the conclusion of ablation studies.


Table (Enocder property)

EncoderArchitectureTime LagWhy includedParams
CNN1D conv on raw timenonevanilla0.21 M
TeChattention over time patches and leadsnoneSOTA MedTS Transformer8.16 M
PhysioWaveattention over (scale, time), waveletsnoneSOTA pretrained ECG14.35 M
ShiftInvariantshift invariant net, no attentioninvariantSOTA shift invariance0.15 M
Delay-TTeCh plus external delay matrixclassical T peakclassical delay9.21 M
Delay-QRSTeCh plus external delay matrixclassical QRSclassical delay9.21 M
Oursattention over morphology, learnable wavelets, delaylearned, gatedproposed15.41 M

Minor

Thank you for the suggestion. We add a high-level overview below at the beginning of Sec. 3:

Time2Track takes ECG and a single rest-state mesh heart and produces the individualized 4D trajectory. To prevent collapsing to the population average, we use learnable multi-scale wavelet decomposition to form morphology and delay tokens for spatial-temporal diffusion conditioning.

Q1

EMC happens during muscular actions, and ECG-to-heartbeat is a perfect fit to evaluate our delay idea due to its specificity. Therefore, EMG2POSE modality remains only in Fig. 1 due to the higher complexity than heartbeat including repeated hand pose and various gesture stages.

Q2

We have chosen TeCh (ICLR 2026), PhysioWave (NeurIPS 2025), and ShiftInvariant (ICLR 2025) as three baselines, which are SOTA on multivariate representation using temporal transformer, wavelet decomposition using time-frequency transformer, and shift invariant representation using MLP, respectively. They are the newest models that focus on delay-relevant features benchmarked over diagnosis, and thus they were chosen.

Reviewer_8XNoOpenReview ↗
Rating
3
Clarity
3
Confidence
5
Originality
3
Quality
2
Significance
3
Read review
Summary

This paper proposes Time2Track, a delay-aware generative framework that synthesizes individualized 4D cardiac motion trajectories from multichannel electrophysiology. The key idea is to explicitly encode inter-channel electromechanical delays by performing FFT-based cross-correlation on multiscale, learnable wavelet coefficients, and embedding the resulting continuous time lags via Fourier positional features, which are then used as conditioning tokens for a motion diffusion backbone. On a large UK Biobank cohort, Time2Track outperforms several encoder baselines paired with the same diffusion backbone, particularly in preserving inter-subject diversity where prior methods tend to collapse toward population-average motions.

Strengths and weaknesses

Pros:

  1. The explicit, differentiable delay tokenization using FFT cross-correlation across channel–scale pairs and subsequent Fourier-feature lag embeddings is original and physiologically well-motivated.
  2. The decomposition of electrophysiology into separate morphology and delay branches is a crisp architectural idea that addresses known phase/misalignment issues in ETS.
  3. Ablations systematically test the necessity of FFT-CC, Fourier lag embeddings, and the delay branch.

Cons:

  1. The approach relies on a subject-specific rest-state mesh p0 at inference. This requirement substantially limits “non-invasive” utility when only surface electrophysiology is available.
  2. No robustness tests to electrode noise, lead dropouts, or different τmax choices; sensitivity to τmax is acknowledged as a limitation but not quantified.
  3. Generalization beyond UKB (different scanners/protocols, pathological cohorts) is not assessed.
Questions
  1. How is p0 (the subject-specific rest-state mesh) obtained at inference in realistic settings where only ECG is available? Can Time2Track operate with a population-average template or a low-cost estimate of p0, and how does performance degrade?
  2. How sensitive are results to the choice of the reference lead (lead II)? Did you try pairwise cross-correlation with an aggregation (e.g., median/attention over references) to avoid reference bias?
  3. You claim generality across ETS modalities; do you have preliminary results for sEMG→hand motion or other organs? If not, could you discuss the expected changes to τmax, scale selection, and lead/channel handling?
Limitations

yes

Paper formatting concerns

N/A

Final justification

The rebuttal provides useful additional analyses, but several central claims remain overstated. The authors themselves acknowledge that the module estimates inter-lead timing rather than a validated electromechanical delay, which weakens the paper’s “physics-based” and physiologically grounded framing. The “foundation model” claim is also insufficiently supported given the limited validation across datasets, modalities, and clinical populations. Moreover, the main evaluation lacks an independent held-out test cohort, and the method relies on a subject-specific rest-state heart mesh at inference, further limiting the claimed generality and non-invasive applicability.

I am also concerned about citation rigor. SE-Diff [35] is clearly mis-cited: the referenced paper is an unrelated ECCV depth-estimation work. References [37] and [38] also duplicate the same Human Motion Diffusion Model paper in arXiv and ICLR forms.

Taken together, these issues raise broader concerns about claim accuracy and manuscript rigor. I therefore recommend a clear reject.

1 comment

C1

We acknowledge that the applicability of our work has not been explored. Time2Track targets clinical scenarios where cardiac MR (CMR) images already exist, focusing specifically on myocardial motion. The subject-specific 3D model can be derived directly from existing scans without requiring additional motion acquisition. Our claim of "non-invasiveness" refers specifically to skip the motion assessment, that is the UKB protocol requiring ECG-gated CMR (20min [1]). We claim that once a single anatomical reference image is obtained (3min [2]), no further imaging or gating is required. Subsequent motion estimation relies solely on resting ECG signals, which is orders of magnitude less expensive. We have not yet evaluated follow-up or longitudinal prediction scenarios, which will be explicitly discussed as future directions.

[1] UK Biobank Imaging modality Cardiovascular Magnetic Resonance (CMR). version 1.0

[2] A Fotaki, et al. "Highly efficient free-breathing 3D whole-heart imaging in 3-min: single center study in adults with congenital heart disease." Journal of Cardiovascular Magnetic Resonance 26.1 (2024): 100008.

C2

We run robustness tests on the diseased subgroup (n=981) of val split to quantify the sensitivity. For electrode noise, we add per-lead Gaussian noise at inference, with σ scaled from each lead's own signal power to hit the target SNR db from 20 → 10 → 5 as listed below. We can observe the degradation is small, ≤ 3 % on fidelity metrics, with diversity unaffected.


Table (Electrode noise)

SNR dBRV↑RMSE↓PAR (→1)|APCR−1|↓|APDR−1|↓
clean0.5760.1790.8920.0270.014
20 dB0.5760.1790.8910.0270.014
10 dB0.5720.1800.8820.0200.012
5 dB0.5620.1830.8710.0020.010

For the lead dropouts, we make lead channel(s) to be zeros at inference as listed below. We observe that dropping the reference lead II leaves fidelity intact (RV 0.576 to 0.575, RMSE +0.004) but hurts the subject diversity performance |APCR−1|. The model can generalize even three leads are dropped.


Table (Lead dropouts)

Dropping leadRV↑RMSE↓PAR (→1)|APCR−1|↓|APDR−1|↓
clean0.5760.1790.8920.0270.014
drop V2 (single chest)0.5790.1780.8880.0240.017
drop II (reference)0.5750.1830.9580.1080.011
drop V1+V2+V3 (3 chest)0.5810.1770.8910.0500.021

For τmax\tau_{max} choices, we alter the encoder's τmax\tau_{max} at inference as below. We can see no metric moves outside its bootstrap CI ([2.5%, 97.5%] 1000-sampling) across a 4× change in τmax\tau_{max}.


Table (τmax\tau_{max} sensitivity)

τmax\tau_{max}RV↑RMSE↓PAR (→1)|APCR−1|↓|APDR−1|↓
25 (±50 ms)0.570 [0.557, 0.585]0.181 [0.177, 0.185]0.8980.0520.011
50 (±100 ms, default)0.568 [0.555, 0.581]0.181 [0.177, 0.186]0.9020.0500.011
75 (±150 ms)0.567 [0.552, 0.581]0.181 [0.177, 0.186]0.9010.0410.012
100 (±200 ms)0.565 [0.552, 0.579]0.181 [0.177, 0.186]0.9030.0460.012

C3

Thank you for the suggestion, we have added new experiments of to show the generalization across pathological cohorts in QZSA Q7. While pathological generalization doesn’t beyond UKB, a new dataset and modality EMG2POSE are also tested, please refer to QZSA W1.

Q1

No, p0 by default is required at inference. However, it can be swapped at inference without retraining by the average of subjects, leaving a resting 12-lead ECG as the only input of Time2Track. In the table below, we measured the degradation by replacing the subject-specific 3D model with the population average to explore the opportunity of being truly non-invasive. The cost falls on fidelity instead of subject diversity: RV drops 0.046 and PAR 0.029, while |APDR−1| rises only 0.017 and |APCR−1| 0.018. Against PhysioWave (PW), the best baseline, Time2Track using only ECG still preserves inter-subject motion diversity 2.2× better (|APDR−1| 0.036 vs 0.079), matches peak amplitude (PAR 0.867 vs 0.868) and is comparable on |APCR−1| (0.052 vs 0.044). However, the motion fidelity is dropped (RV 0.591 vs 0.634, RMSE 0.182 vs 0.172). A population template therefore retains the subject diversity, which is the claim of this paper, while subject anatomy remains necessary for the best absolute geometry.


Table (Population avg as p0)

Subject-specific (PW)Subject-specific (Ours)Population p0 (Ours)Δ
RV ↑0.6340.6370.591-0.046
PAR →10.8680.8960.867-0.029
|APCR−1|↓0.0440.0340.052+0.018
|APDR−1|↓0.0790.0190.036+0.017
RMSE ↓0.1720.1510.182+0.031

Q2

Please see QZSA Q8 for ref lead sensitivity. We have replaced the original delay map with full L x L x C delay map for tokenization, but the results are not available until 1 to 2 days. However, a preliminary result of ES timing classification shows aggregation (mean or median) of the full delay map underperforms lead II. Consistent with results on reference lead-sensitivity, lead II demonstrates significantly enhanced performance compared to the others.


Table (no ref lead)

AUC
lead II delay0.5972
mean0.5900
median0.5627

Q3

Yes, we have preliminary results on EMG2POSE, please refer to QZSA W1.

Reviewer_QZSAOpenReview ↗
Rating
4
Clarity
3
Confidence
5
Originality
3
Quality
3
Significance
2
Read review
Summary

The paper proposes Time2Track, a delay-aware diffusion model, conditioned on ECG, that generates individualised 4D cardiac motion. The encoder combines a morphology branch based on multi-scale wavelet tokenisation with a delay branch that explicitly estimates inter-lead temporal shifts. The goal is to avoid the common failure mode where generative models collapse to an average cardiac motion and fail to preserve subject-specific dynamics.

Strengths and weaknesses

Strengths: The paper addresses the question of generating subject-specific cardiac motion from electrophysiology. The originality is clear, especially the argument that electromechanical delay and inter-lead timing differences should be explicitly modelled. The related work is broad and generally well presented. The proposed delay-aware conditioning mechanism is original and interpretable. Weaknesses: The terms “foundation model” and “agnostic to electrophysiology type” seem overstated unless the authors demonstrate transfer across datasets, pathologies, modalities, or downstream tasks. The current evaluation appears to focus mainly on one task, ECG-conditioned 4D cardiac motion generation, using one dataset source. UK biobank is mostly composed of healthy volunteers. The time delay between leads is very small in such population, and 500Hz is limited to quantify such delays. The evaluation appears to rely on a train/validation split from UK Biobank rather than an independent held-out test cohort or external validation set. Since the main results and ablations seem to be reported on the validation set, the evaluation may be affected by model-selection bias. The central claims rely heavily on APCR/APDR diversity metrics, but the large standard deviations are not sufficiently discussed. Finally, the application is not clear, as the application of the method requires a 3D image to build the patient-specific 3D model, therefore motion could be measured instead of predicted.

Questions

The paper refers to a “foundation model”, but the evaluation seems to focus on one dataset and one main task. Can the authors provide evidence of transfer across datasets, pathologies, modalities, or otherwise tone down this claim? The experimental section states that the work involves two applications (Section 4, Datasets), but only the UKB ECG-to-4D heart motion task appears to be evaluated. What is the second application? Is there a separate held-out test set, or are all final results reported on the validation split? How were hyperparameters, checkpoints, and architectural choices selected? Can the authors discuss the large standard deviations in APCR/APDR-related metrics? The qualitative results mainly emphasise population-level diversity. It would be useful to include subject-level visualisations at different time steps in the appendix. Can the authors discuss more deeply or evaluate whether the model generalises to pathological motion patterns, arrhythmias, or heart failure? The delay branch uses lead II as the reference lead r. Could the authors justify this choice and comment on whether the results are sensitive to the reference lead?

Limitations

The limitation section should be expanded. The authors should discuss the lack of pathology evaluation and the restriction to a low-dimensional 388 control point representation.

Paper formatting concerns

NA

1 comment

W1 Overstated terms; Q1 Q2 Transfer to EMG2POSE

EMC happens during muscular actions, and ECG-to-heartbeat is a perfect fit to evaluate our delay idea due to its specificity. Therefore, EMG2POSE modality remains only in Fig. 1 due to the higher complexity than heartbeat including repeated hand pose and various gesture stages. To demonstrate the foundation nature of our delay tokenization method, we have run the experiments on the modality sEMG using EMG2POSE dataset. We cropped sEMG sessions to have only the first gesture, then we used vemg2pose [1] and EMGFormer [2] as the baseline to against delay-injected versions. The sEMG experiments are repeated with 3 different random seeds. As listed below, models injected with delay tokens mostly outperform baselines. In the complete val split (all) and the first 4 biggest subgroups of gesture stage, +delay has at least 3 out of 4 metrics been improved on the held-out test split.

[1] S Salter, "emg2pose" NIPS 2024

[2] Z Xi, “EgoEMG” arXiv 2026

UKB has 10% subjects that are not healthy with pathological difference based on EHR data. Refer to Q7 for the generalizability for diseased subgroups.


Table (EMG2POSE exp)

Val subgroupmethodRMSE|PAR-1||APCR-1||APDR-1|
ALL (n=6,151)EMGFormer0.663±0.0030.483±0.0050.066±0.0050.019±0.002
+delay0.666±0.0030.469±0.0100.061±0.0050.020±0.001
vemg2pose0.530±0.0010.555±0.0040.088±0.0130.025±0.002
+delay0.529±0.0000.561±0.0030.076±0.0060.025±0.001
HandOverHandCountingUpDownFingerWigglingSpreading (n=843)EMGFormer0.748±0.0040.432±0.0020.059±0.0080.015±0.001
+delay0.750±0.0040.408±0.0120.039±0.0070.017±0.001
vemg2pose0.646±0.0020.466±0.0030.022±0.0120.018±0.001
+delay0.643±0.0030.478±0.0030.011±0.0100.018±0.001
ShakaVulcanPeace (n=710)EMGFormer0.777±0.0040.521±0.0090.023±0.0140.028±0.001
+delay0.786±0.0070.509±0.0170.015±0.0090.027±0.001
vemg2pose0.585±0.0020.613±0.0070.235±0.0180.038±0.004
+delay0.587±0.0030.617±0.0070.225±0.0020.038±0.001
HookEmHornsOKScissors (n=710)EMGFormer0.890±0.0040.356±0.0090.185±0.0070.032±0.001
+delay0.893±0.0030.338±0.0130.207±0.0080.031±0.001
vemg2pose0.562±0.0020.606±0.0050.156±0.0040.038±0.001
+delay0.561±0.0010.609±0.0060.139±0.0210.039±0.002
FingerFreeform (n=703)EMGFormer0.678±0.0050.387±0.0170.155±0.0150.019±0.000
+delay0.676±0.0040.357±0.0090.143±0.0050.018±0.001
vemg2pose0.616±0.0020.448±0.0030.092±0.0050.020±0.000
+delay0.614±0.0020.453±0.0030.097±0.0080.020±0.001

W2 small delay and 500Hz limit

We agree that the delay is small. However, the median inter-lead T-peak delay is 8 ms (interquartile range: 2–30 ms) in UKB. 500Hz (2ms) is therefore not limiting such delay to be quantified by Time2Track.

W3 Q3 No held-out test split

Although there is no held-out test split, the model-selection bias doesn’t affect the evaluation according to our model selection protocol. We select the best model by the training objective itself with the one-step DDPM denoising loss. No diversity or fidelity metric ever entered the best model selection. On the other hand, we have expanded experiments to the EMG2POSE dataset in W1, which contains a held-out test split, and the new results above further consolidate that the contribution of delay tokens is not biased by model selection.

W4 Q5 high std

We apologize that the std numbers present in the paper were incorrectly calculated. We present |APCR-1| and |APDR-1| to show lower-is-better scores, but std for |APCR-1| incorrectly used |std(APCR)– 1|. We have revised the manuscript with corrected numbers using std(|APCR-1|) and std(|APDR-1|), which are in ranges from 0.006 to 0.012 and 0.037 to 0.078, respectively.

W5 Application is not clear

We acknowledge that the applicability of our work has not been explored. Time2Track targets clinical scenarios where cardiac MR (CMR) images already exist, focusing specifically on myocardial motion. The subject-specific 3D model can be derived directly from existing scans without requiring additional motion acquisition. Our claim of "non-invasiveness" refers specifically to skip the motion assessment, that is the UKB protocol requiring ECG-gated CMR (20min [1]). We claim that once a single anatomical reference image is obtained (3min [2]), no further imaging or gating is required. Subsequent motion estimation relies solely on resting ECG signals, which is orders of magnitude less expensive. We have not yet evaluated follow-up or longitudinal prediction scenarios, which will be explicitly discussed as future directions.

[1] UK Biobank Imaging modality Cardiovascular Magnetic Resonance (CMR). version 1.0

[2] A Fotaki, et al. "Highly efficient free-breathing 3D whole-heart imaging in 3-min: single center study in adults with congenital heart disease." Journal of Cardiovascular Magnetic Resonance 26.1 (2024): 100008.

A cheaper option is shown in 8XNo Q1 by replacing patient-specific 3D model with the population average.

Q4 Hyperparam, checkpoint choice

The checkpoint selection refers to W3. Additionally, there was no hyperparameter search for every model. All training utilized the same config, and the delay-relevant ones were decided based on physiological characteristics rather than determined through tuning as stated in Appendix.

Q6 Subject-level visualization

We agree and have produced them with typical subjects that have an early ES or late ES, where Time2Track replicated the subject diversity, but baselines collapsed. GIF of mesh motion of two subjects can be found in the anonymous code repo mentioned in Appendix.

Q7 Generalizability across pathologies

We stratified the subjects among val split by the ICD-10 code and got >10% subjects have a cardiac disease history (981 any-cardiac, 7,112 healthy subjects). We re-ran all models for metrics used in the paper to validate if Time2Track can generalize from healthy controls to diseased subjects. Due to each diseased subgroups have various sample sizes n, so we compared only against n healthy subjects randomly sampled from val split. Time2Track degrades less than baselines.


Table (Pathology vs healthy) (Δ = pathology − own healthy)

RMSE↓PAR (→1)|APCR−1|↓|APDR−1|↓
Ours0.1790.8880.0120.016
Δ Ours+0.001+0.009-0.025+0.004
CNN0.1340.4720.2300.151
Δ CNN+0.005-0.007+0.034-0.001
TeCh0.1340.3940.3680.184
Δ TeCh+0.005+0.008+0.064-0.005

Q8 Ref lead sensitivity

Lead II is widely considered the standard reference lead in clinical electrocardiography with high SNR [1]. Empirically, we swept the reference lead to two alternatives and re-trained Time2Track to test the sensitivity of reference lead. As listed below, replacing lead II to others will degrade the performance.


Table (Ref lead sensitivity)

Ref leadRV ↑RMSE ↓PAR (→1)|APCR−1|↓|APDR−1|↓
II (in paper)0.6370.1510.8960.0340.019
aVR0.5900.1810.9480.0410.022
aVL0.5920.1810.9340.0740.024

[1] Meek, Steve, and Francis Morris. "Introduction. I—Leads, rate, rhythm, and cardiac axis." Bmj 324.7334 (2002): 415-418.

Lim

Thanks for the valuable comments. We have included two additional limitations to the current one:

Second, although we evaluate subjects carrying cardiac diagnoses, the UKB imaging cohort is about 90% healthy, and its labels derive from registry codes rather than adjudicated imaging, so behavior under severe or acute pathology remains untested. Third, cardiac motion is represented by 388 control points, a resolution coarser than ventricular wall thickness, so regional wall-motion abnormalities and other fine-scale kinematics lie beyond the reach of both our model and the metrics used to evaluate it. Future work will focus on higher-resolution representations and validation in clinical cohorts, and on extending the framework to real-time, continuous motion tracking across a broader application of severe cardiovascular and neuromuscular disorders.

Comments on the paper

1 comment
Meta-review

(a) Scientific Claims/Findings

The paper proposes Time2Track, a delay-aware conditional diffusion model that generates individualized 4D cardiac motion sequences from same-day ECG recordings. The core claim is that by explicitly extracting and embedding inter-lead temporal delays via a learnable wavelet decomposition, the model successfully captures electromechanical coupling (EMC) dynamics, preserving inter-subject diversity and preventing the generative model from collapsing to a population-average motion.

(b) Strengths

  • [QZSA, 8XNo, PhZA] Strong physiological motivation and original architectural design. Explicitly tokenizing the electromechanical delay and separating it from waveform morphology is an elegant, principled approach that directly targets a known failure mode in continuous sequence generation.
  • [8XNo, PhZA] Addresses a highly relevant, previously underexplored task with clear clinical potential, supported by well-designed ablation studies that validate the necessity of the core FFT cross-correlation and lag embedding components.

(c) Weaknesses

  • [QZSA, 8XNo, PhZA] Overstated "foundation model" claims. The manuscript frames the method as a general foundation model agnostic to electrophysiology types, yet the empirical evaluation is strictly limited to a single dataset (UK Biobank) and a single modality (ECG). In particular, the UK Biobank cohort consists primarily of healthy volunteers, leaving the model's performance on abnormal or pathological cardiac motions untested.

(d) Recommendations

Please address the weaknesses above and within reviewer comments during the rebuttal.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.