- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 2
- Significance
- 3
Read review
Summary
The paper proposes a parameter-efficient framework to adapt frozen 10s ECG foundation models to longer and variable-length recordings, combining a hierarchical positional encoding scheme, soft prompt tuning, a locality-aware soft contrastive objective, and a dynamics-aware consistency loss guided by teacher-derived affinity.
Strengths and weaknesses
Strengths
- The motivation for extending 10-second ECG foundation models to long-horizon settings is clinically important.
Weaknesses
-
Computational overhead is not reported
-
Moderate performance improvement
Questions
-
The paper demonstrates that long-horizon adaptation is technically feasible, but does not fully establish that the evaluated settings correspond to the scenarios where long-horizon ECG modeling is clinically necessary. Please discuss downstream tasks that need long term monitoring. Also, the paper also benefit from testing wearable single lead ECG FMs (support long-term monitoring essensially more), instead of just 12-lead ECG FM (12 lead ECG with only 10s is very common and standard already in clinical setting, that doctors read daily).
-
The proposed framework is evaluated exclusively on transformer-based ECG foundation models, and several of its key components, including hierarchical positional encoding and prompt tuning, are inherently tied to transformer architectures. Furthemore, the effectiveness of the semantic extension appears dependent on the quality of the teacher backbone, limiting the generality of the proposed approach. The authors should evaluate and discuss it.
-
It remains unclear how experiments with finetuning baselines are conducted. It would be not persuadable if: the work finetunes 10s-ECG FMs, using 180s windows. The right thing to do I think is: finetuning 10s-ECG FMs on 10s windows, then, test those finetuned models with 180s by spliting to 10s and do some aggregation/ensemble for final results. (I really question this since I am quite surprised when the results of Full Fine-tuning is quite low in Table 1).
Limitations
-
Computational overhead, parameter counts, FLOPs, GPU memory usage, training time, or inference latency,… are not reported despite repeated claims of parameter efficiency.
-
Several reported improvements are relatively modest, yet no seed-level variance estimates or statistical significance analyses are provided. Also, the gains may be even smaller when testing stronger ECG FMs such as ECGFounder, D-BETA, MELP.
-
The relationship between the proposed consistency objective and existing stop-gradient representation learning methods is not sufficiently discussed.
-
The work relies on non-overlapping 10-second segmentation. Since clinically important events may occur near segment boundaries, the impact of stride choice deserves discussion.
Paper formatting concerns
No
Final justification
The additional experiment on (1) Generality across Architectures and Teacher Backbones, (2) Full fine-tuning protocol, and (3) Statistical uncertainty resolve my previous concerns. However, the claimed parameter efficiency is not backed up with computation overhead measurement. Therefore I increased the rating from borderline reject to borderline accept.
Meta-review
This paper Needs Clarification during Response Period. It proposes a parameter-efficient framework for adapting frozen 10-second ECG foundation models to 1–5 minute recordings using hierarchical positional encoding, soft prompts, locality-aware contrastive learning, and dynamics-aware consistency. Reviewers 51AV and UWoS find the problem practical, the evaluation comprehensive, and the gains consistent across several ECG backbones, tasks, and recording durations.
The main concern is whether the evaluated 180-second setting establishes a clinically meaningful long-horizon problem. Reviewer 51AV notes that VTaC performance saturates beyond 60 seconds, while Reviewer UWoS cautions that 1–5 minutes is still far from 24–48 hour Holter monitoring. Reviewer HjLT also asks for wearable single-lead ECG evaluation, where longer monitoring is more natural than for standard 12-lead ECGs.
The empirical case would also benefit from stronger controls. The improvements are moderate, with no seed-level variance, CIs, or significance tests. Reviewer HjLT questions whether the full fine-tuning baseline is implemented fairly and notes that stronger ECG FMs, such as ECGFounder, D-BETA, and MELP, are absent. The effects of soft prompts and global positional encoding are not separated, while the gains appear to come mainly from the locality-aware loss.
Finally, the claimed variable-length and parameter-efficient properties are not fully evaluated. The method uses fixed non-overlapping 10-second segments and a finite learned positional table, with no tests on unseen lengths, overlapping windows, or segment-boundary events. FLOPs, GPU memory, training time, inference latency, and parameter overhead are also missing.
The rebuttal should prioritize addressing the following concerns raised by reviewers: