- Rating
- 5
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 4
Read review
Summary
CLEF introduces a clinically grounded long-context EEG foundation model that takes 20-minute EEG as 3D multitaper spectrogram tokens, enabling tractable Transformer modeling at session scale. By aligning the patient level embedding with report and EHR, this framework improves the models performance across multiple downstream tasks and backbones. The paper propose a 234-task benchmark spanning disease phenotypes, medications and EEG features, where CLEF improves performance over prior EEG foundation models across most tasks.
Strengths and weaknesses
Strengths:
- The paper presents a clinically motivated formulation of EEG foundation modeling, moving beyond short-window BCI-style decoding toward patient-level clinical representation learning from full EEG sessions.
- The framework is evaluated broadly across multiple EEG foundation-model baselines, a large 234-task clinical benchmark, external cohorts, model scales, and data scales.
- The proposed QA-consistency pipeline for selecting the report-summarization prompt is a useful and practical contribution. It provides a systematic way to standardize free-text EEG reports while attempting to preserve clinically salient electrographic information.
- The inter-channel-emphasized reconstruction loss, addresses a limitation of naive spectrogram reconstruction, where common-mode activity may dominate the loss while clinically important inter-channel differences, such as focal or lateralized abnormalities, are underweighted.
- The structured EHR codebook design is also reasonable. Instead of serializing EHR records into arbitrary text, the method treats demographics, diagnoses, and medications as structured sets of discrete codes, which better matches the semantics of EHR data and avoids unnecessary dependence on code ordering or subword tokenization.
Weaknesses:
- The claim around 20-minute clinical EEG context should be toned down. Long-context modeling is clearly useful for clinical EEG, but 20 minutes is not universally sufficient. Brain states can transition rapidly, and transient events such as seizures, arousals, medication effects, or state changes may be diluted when represented by a single session-level embedding. Conversely, for sleep architecture, ICU monitoring, or multi-day continuous EEG, 20 minutes may still be too short.
- The separation between pretraining and downstream evaluation is not fully convincing. Although the authors use patient-disjoint splits and freeze the encoder during probing, both pretraining and the 234-task benchmark are derived from HEEDB. Moreover, the model is explicitly aligned with HEEDB reports and EHR codes during pretraining, while many downstream labels are also derived from HEEDB EHR or reports.
- The model is largely built around a fixed 19-channel clinical EEG montage. Although the authors report robustness to reduced channel subsets, the core tokenizer and spectrogram representation assume a standardized montage.
- Limited reproducibility. No anonymized assets or URL were provided.
Questions
- Many of the 234 clinical tasks may be highly correlated through shared disease severity, medications, ICU status, or documentation patterns. Could the authors report performance after grouping correlated labels or controlling for major confounders, and clarify which CLEF components contribute most to each task group?
- Since prior EEG foundation models were mainly designed for short-window decoding, are they disadvantaged by the sliding-window mean-pooling protocol? Would stronger long-context baselines without clinical alignment or hierarchical temporal pooling models, reduce the reported gap?
- CLEF compresses each session into a single patient-level embedding. Does this embedding preserve temporally localized abnormalities, or mainly capture global clinical state? How would CLEF perform on tasks requiring precise event localization or state-transition timing?
- CLEF is anchored to a standardized 19-channel montage. Although reduced-channel robustness is reported, how would the model handle non-standard montages, such as 4-channel EEG, bipolar derivations, neonatal EEG, or site-specific electrode layouts?
Limitations
yes
Paper formatting concerns
Limited reproducibility. No anonymized assets or URL were provided.
Final justification
The rebuttal convincingly addresses my concerns: holdout analysis rules out label leakage, task grouping confirms robustness, and attention pooling shows the performance gap is not a pooling artifact. The authors commit to explicitly stating key limitations in the revision. I raise my score from 4 to 5.
We thank the reviewer for the careful and constructive evaluation and for recognizing CLEF’s clinical motivation, broad evaluation, QA-consistency pipeline, inter-channel-emphasized reconstruction loss, and structured EHR design. We address each concern below.
Context Window Length (W1)
We agree and will narrow this claim. The 20-minute context is a clinically motivated operating point, consistent with the ACNS minimum-duration recommendation for routine EEG, rather than a universally optimal horizon. Table 17 shows that performance improves with longer recordings and degrades gracefully with shorter inputs. CLEF’s 5-second spectrogram windows preserve short-timescale structure, while the session encoder aggregates information across the 20-minute recording. However, we do not claim validated event localization or adequacy for sleep architecture or multi-hour or multi-day continuous EEG. We will revise the text to describe 20 minutes as a clinically relevant extension beyond short-window modeling and identify longer-horizon hierarchical modeling as future work.
Separation Between Pretraining and Downstream Tasks (W2)
Our evaluation is not limited to HEEDB. We evaluated CLEF on external datasets not used for training, TUAB, TUEP, and HSP, which differ from HEEDB in institution, montage, and labels. Table 2 shows that CLEF outperforms the baselines even though some baselines used TUAB and TUEP during pretraining.
To further separate pretraining from downstream evaluation, in Section 4.4 we randomly selected 45 holdout tasks from the original 234 and removed their direct and near-direct concepts from clinical-alignment supervision. For reports, we removed the target term, lexical variants, abbreviations, and curated synonyms. Within medications, we also removed generic, active-ingredient, and brand names. For structured EHR data, we removed codes directly mapping to the target and prespecified ontology-local codes representing the same or a near-equivalent concept.
We then reran the alignment stage with the filtered supervision. Across the 45 tasks, mean AUROC was 0.744 with the concepts included, and 0.748 with them held out, compared with 0.666 for the oracle best baseline per task (which selects for each task the best performance across baselines). Thus, removing direct and near-direct target supervision caused no measurable performance degradation.
We also evaluated subsets of held-out tasks with low conditional co-occurrence with any pretraining concept, based on conditional probability $P(t=1 \mid c=1) $ for task t and pretraining concept c. CLEF maintained its gains, as shown below.
CLEF’s gains are therefore not explained by label leakage between pretraining and evaluation. Instead, the results suggest that alignment across diverse clinical concepts teaches reusable, foundational EEG features rather than a separate lookup for each supervised concept.
Finally, pretraining with semantically related supervision is an intended mechanism, not evaluation leakage. CLIP (Radford et al.) and BiomedCLIP (Zhang et al.) learn visual features from captions containing downstream concepts; CSFM (Gu et al.) pretrains on ECG and PPG signals paired with clinical or machine-generated reports; and NeuroLM (Jiang et al.) uses language-based multitask supervision. CLEF follows the same convention by steering the signal encoder toward clinically relevant features. Our additional analysis further shows that its benefit is not limited to tasks with identifiable related concepts in the alignment data.
Non-Standard montage (W3,Q4)
The paper evaluates robustness to reduced channel availability within the canonical 10–20 layout: Table 16 reports results for 1-, 3-, 6-, 12-, and 19-channel subsets, including a 3-channel PSG-style configuration. CLEF is trained with channel masking and imputation, and it also performs strongly on the external six-channel HSP cohort. These results support robustness to missing or reduced channels within the standardized layout. We agree, however, that they do not establish robustness to fundamentally different configurations, such as bipolar derivations, neonatal montages, or site-specific non-canonical layouts. We will state this limitation explicitly and identify montage-aware spatial encoding as future work.
Reproducibility (W4)
Comprehensive implementation and training details are provided in Appendix C, and we also commit to releasing the code and model upon acceptance to facilitate independent replication and downstream research.
Task Correlation and Grouping (Q1)
As suggested, we analyzed label correlation and task grouping. Pairwise phi correlation between the 234 tasks is low overall (median 0.010): of the 27,261 label pairs, only 149 (0.55%) exceed |ϕ| = 0.3, 53 (0.19%) exceed 0.5, and 24 (0.09%) exceed 0.7. Collapsing every family linked at |ϕ| ≥ 0.5 yields 198 families. Macro-averaging over these families (averaging within each family, then across families) changes little relative to the flat average over all 234 tasks: 0.657 / 0.670 / 0.736 vs. 0.658 / 0.671 / 0.737 for the per-task best baseline, CLEF (Recon-only), and CLEF (Full), respectively. A PCA of the correlation matrix confirms no dominant axis: the three leading components explain only 3.7%, 2.5%, and 2.0% of label variance, and none beyond the tenth reaches 1%. Clustering the 234 tasks on their leading 25 principal-component coordinates (k-means, k = 10) and naming each cluster clinically yields groups that cut across our original feature/disease/medication taxonomy (e.g., antiseizure medications cluster with epileptiform activity and epilepsy diagnoses).
Across every group, Stage II alignment contributes the majority of CLEF's improvement over the best prior model, accounting for 65–98% of the total gain. Its relative contribution is largest for structural brain disease/neurosurgical care and for psychiatric disorders/psychotropic maintenance (both 98%), consistent with these labels having heterogeneous, subtle, or nonspecific EEG signatures that benefit from the clinical context in reports and EHRs, and smallest for sedation and post-arrest critical care (65%), where characteristic patterns are directly visible in the EEG and already captured by Stage I reconstruction.
Baseline Fairness / Pooling (Q2)
We agree that mean-pooling could disadvantage short-window baselines, and we tested this by replacing mean-pooling with attention pooling. We ran this comparison with LaBraM because it is a strong baseline without text alignment, and its longer operating window (15s) limits the number of segments per 20-minute session, making attention-pooling training feasible within the rebuttal period. Due to time constraints, we conducted the comparison on the 45-task set used in our holdout experiments.
LaBraM's performance remained essentially unchanged, 0.657 AUROC with mean pooling and 0.656 with attention pooling, while CLEF reached 0.744 on the same tasks, retaining an 8.8-point advantage. This indicates that the gap is not simply that mean pooling fails to identify informative windows; rather, short-window models have not learned representations of the long-term structure and dependencies across a session, which a more expressive pooling head alone cannot recover.
Temporally Localized Tasks (Q3)
CLEF’s patient-level embedding is designed to summarize the clinical state of an entire session, rather than recover exact event timing or localize abnormalities to specific segments; we will clarify this limitation in the revision. Nevertheless, the embedding retains compressed evidence of temporally localized phenomena, achieving a mean AUROC of 0.833 across EEG-feature tasks, including generalized periodic discharges (0.851), epileptiform activity (0.844), lateralized periodic discharges (0.840), and focal slowing (0.792). These results show that CLEF can capture the presence of localized-event-based abnormalities, but supporting precise event localization and state-transition timing is left for future work.
We hope these clarifications and new results resolve the reviewer’s concerns, and that they would consider raising the score. If any questions or concerns remain, please feel free to ask and we would be happy to provide further clarification.