- Rating
- 5
- Clarity
- 4
- Confidence
- 4
- Originality
- 3
- Quality
- 4
- Significance
- 3
Read review
Summary
The authors propose a multi-time-scale approach, known as MAGE, to improve EEG foundation models. They argue that different downstream tasks require different time scales, making fixed time windows suboptimal. To address this, the approach introduces several key components: multi-scale tokenization, multi-scale attention, and a multi-scale aggregator, which respectively extract features at different time scales, capture spatiotemporal dependencies, and weight and combine information across scales. The authors conduct extensive experiments across several EEG datasets (e.g., motor imagery, video stimulation, sleep staging, and abnormality detection) and compare their method against relevant baselines. Multiple evaluation metrics demonstrate that MAGE outperforms existing approaches across diverse downstream tasks.Overall, the problem is important, and this work has the potential to influence future research. However, several clarifications and additional details are needed, which may affect my final assessment.
Strengths and weaknesses
Major strengths
- Improving EEG foundation models can have a profound impact on many brain–computer interface (BCI) applications.
- EEG representation learning is still relatively novel, leaving many avenues to explore, including this one on time scaling.
- The paper is well written and easy to follow.
- The architecture is clearly and reasonably explained.
- The experiments across different datasets and downstream tasks are well conducted, with appropriate data splits.
- The paper compares against other foundation-model-based approaches.
- The results are supported by multiple evaluation metrics.
- The proposed approach outperforms many existing methods.
Major weaknesses
-
I understand that fixed window sizes introduce time–frequency trade-offs, as this is a well-established issue in signal processing. However, it is not clear why a short window is described as capturing only high-frequency components (i.e., losing low-frequency information), while a long window is said to retain “low-frequency oscillations but obscure transient details,” as stated in the introduction. Typically, the trade-off is between temporal and frequency resolution: short-time windows provide good temporal resolution but poor frequency resolution (e.g., difficulty distinguishing closely spaced frequencies), whereas long-time windows provide good frequency resolution but poor temporal resolution. This trade-off is fundamentally governed by the time–frequency uncertainty principle. This point would benefit from clarification or correction, ideally supported by appropriate references or experimental evidence.
-
It is unclear why multi-scale learning is necessary. The authors do not adequately motivate or provide a detailed analysis of when different time scales are needed in the introduction, especially given that most EEG data used in foundation models is concentrated in low-frequency ranges (e.g., below ~128 Hz). While the manuscript mentions frequency scaling for different applications, this primarily implies selecting temporal window lengths that provide sufficient frequency resolution. From this perspective, longer time windows would seem preferable in many cases; however, this comes at the cost of reduced temporal resolution and diminished ability to detect event timing. The authors do not clearly articulate this trade-off, nor do they support their claims with established time-window considerations grounded in neuroscience or psychology studies. Clarifying and substantiating these points would strengthen the motivation for multi-scale learning.
-
The following approaches use multi-time-scale methods in speech and audio applications involving EEG. Although these studies have not been conducted in the context of EEG foundation models or the specific downstream tasks considered here, the authors should still reference them and clearly discuss how their approach differs.
- Fan, Cunhang, Jingjing Zhang, Hongyu Zhang, Wang Xiang, Jianhua Tao, Xinhui Li, Jiangyan Yi, Dianbo Sui, and Zhao Lv. "MSFNet: Multi-scale fusion network for brain-controlled speaker extraction." In Proceedings of the 32nd ACM International Conference on Multimedia, pp. 1652-1661. 2024.
- Fan, Cunhang, Ying Chen, Jian Zhou, Zexu Pan, Jingjing Zhang, Youdian Gao, Xiaoke Yang, Zhengqi Wen, and Zhao Lv. "M3anet: Multi-scale and multi-modal alignment network for brain-assisted target speaker extraction." arXiv preprint arXiv:2506.00466 (2025).
- Li, Lu, Cunhang Fan, Hongyu Zhang, Jingjing Zhang, Xiaoke Yang, Jian Zhou, and Zhao Lv. "Mhanet: Multi-scale hybrid attention network for auditory attention detection." arXiv preprint arXiv:2505.15364 (2025).
- Feng, Zehui, Dian Zhu, Junxuan Li, Yang Bai, and Ting Han. "MSANET: Multi-Scale Semantic Aggregation Network for Brain-Assisted Speech Enhancement in Multi-Speaker Conditions." In ICASSP 2026-2026 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), pp. 6846-6850. IEEE, 2026.
- Fan, Cunhang, Sheng Zhang, Jingjing Zhang, Enrui Liu, Xinhui Li, Gangming Zhao, and Zhao Lv. "Dmf2mel: A dynamic multiscale fusion network for eeg-driven mel spectrogram reconstruction." In Proceedings of the 33rd ACM International Conference on Multimedia, pp. 6977-6985. 2025.
-
Some of the performance differences between the proposed MAGE model and the second-best approach appear numerically small in Tables 1–5. The authors should conduct statistical significance tests to determine whether these differences are meaningful.
-
The authors employ a stochastic importance weighting function, as defined in Equation (7), which I assume is also used to produce the results shown in Figure 2. First, this relationship should be stated more clearly (i.e., how Figure 2 is generated). Second, the authors should justify their choice of importance function. What alternative options exist, and why was this particular formulation selected over them? This clarification is important, as it is unclear whether a different importance function would yield the same profile shown in Figure 2.
-
Also based on Figure 2, PhysioNet-MI and SHU-MI are both motor imagery datasets, so it is unclear why their importance weight distributions differ so substantially. One would expect datasets for the same downstream task to exhibit similar distributions, but this is not observed. The authors should discuss the reasons for this discrepancy and its implications. For example, how should one determine an appropriate window length for a new motor imagery dataset? The authors should also support these findings with evidence from neuroscience or psychology studies related to these tasks.
-
The authors select three patch sizes (250 ms, 500 ms, and 1 s), but do not explain the rationale behind these choices. Since multi-time-scale modeling is the primary contribution of this work, these selections should be clearly motivated and justified. In particular, how do these window lengths relate to the characteristics of the different downstream tasks?
-
For the results in Table 2, the authors should clarify how MAGE was modified to operate under single time-scale conditions. Additionally, for the MAGE-router results, the authors should specify the extent of computational reduction achieved.
Minor issues
-
For equation (1), the authors need to define \phi_temp and \phi_spec.
-
Do the numbers in the tables (1-5) indicate average performance with standard deviation, average with standard error, etc? This should be specified within the captions. It'll also be useful to clearly mention the downstream tasks (e.g., sleep, MI, emotion,...) within the tables just for readability.
-
The multi-timescale target encoder is shown in Figure 1, but it is not mentioned anywhere within the paper.
-
Just to better tie the sections with Figure 1, it would be helpful if section 3.2 was changed from "Multi-timesscale Attention" to "Multi-timescale Encoder".
Questions
-
How does a short/long time window lead to the loss of low or high frequency information?
-
Why is multi-scaling needed?
-
How were the different patch sizes selected, and how do they relate to the downstream tasks?
-
How does the proposed multi-scale approach compare to existing multi-scale approaches?
Limitations
-
The motivation for needing different time scales needs to be strengthened. They should at least list typical time scales for different downstream tasks.
-
In the author's paper checklist, they select [N/A] when referring to the potential broader impacts that could result from this work, indicating that there is no societal impact of the work. I disagree with this and the authors should discuss/mention how this work could possibly improve clinical or research studies involving EEG. If there aren't any societal benefits to this, then why is it being done?
Paper formatting concerns
N/A
Final justification
The author's addressed my concerns.
We appreciate the reviewers for their constructive comments.
Our hypothesis is based on the information bottleneck inherent in fixed-size embeddings:
This phenomenon is also discussed in literature [1, 5]. [1] notes that for non-stationary signals such as EEG, shorter time windows are more effective at extracting high-frequency components, while longer windows are better suited for isolating low-frequency oscillations. Furthermore, [5] demonstrates a similar principle: it utilizes a local branch (functioning as a short window) to capture fine-grained, foreground features, together with a global branch (functioning as a long window) to mitigate long-range background interference. In the revised manuscript, we will clarify this mechanism based on these supporting citations.
Multi-scale learning is essential in EEG analysis, as current literature indicates that although EEG data is concentrated in low-frequency ranges, distinct neural features map directly onto specific spectral ranges, such as the α, β, and γ bands. For instance, motor imagery decoding heavily relies on µ- and β-desynchronization, whereas sleep staging depends on distinguishing δ and σ waves. Consequently, current deep learning research for EEG has shifted toward multi-scale feature extraction like in related work [2, 4] or CSBrain, Medformer. As highlighted by [2], traditional methods often overlook the importance of this multi-scale information, failing to fully account for the long- and short-range dependencies inherent in temporal features. To address this, recent architectures adopt multi-scale learning to capture crucial information across varying frequency bands, leading to superior generalization across diverse clinical and cognitive tasks.
Although the suggested works do not focus on EEG foundation models, they are highly relevant and strongly support our core arguments.
Specifically, MSFNet [1] addresses brain-assisted speaker extraction by applying convolutions with varying kernel sizes to the speech modality. M3ANet [2] introduces a contrastive learning module to obtain temporal alignment between EEG and speech modalities. We find this alignment strategy that provides valuable inspiration for our future work on multi-biosignal foundation models.
Meanwhile, methods such as MHANet [3], MSANet [4], and DMF2Mel [5] explore the multi-scale characteristics of the EEG signals by adopting U-Net architectures or convolutional layers with varying kernel sizes. While these methods use multi-scale architectures to fuse and enrich latent features early in the network or layer-by-layer, our proposed method, MAGE, applies different window sizes to create tokens at multiple scales. MAGE processes these tokens separately before utilizing late aggregation. We find this approach much more flexible for a foundation model setup, as different downstream tasks may require different scales.
Given the high relevance of these studies in supporting the benefits of multi-scale learning, we have included them in the related work section and discussed how they inform potential future solutions.
The large standard deviations in our aggregated results are due to the substantial inter-subject variability in EEG signals.
Therefore, to provide further evidence of MAGE's consistent performance, we employed a corrected two-sided paired t-test (p<0.05) [6] across all folds and 3 random seeds. The corrected paired t-test is designed to account for the non-independence of cross-validation folds. Demonstrating significance under this strict condition confirms the high reliability of the method.
The results show that MAGE consistently matches or exceeds the performance of three high-performing baselines (CSBrain, CBraMod, and LaBram). Specifically, MAGE performs significantly better than all baselines on PhysioNet-MI and FACED. On BCIC2a, KaggleERN, and Sleep-EDFx, it significantly outperforms LaBram and CBraMod for the first two. For TUAB and SHU-MI, MAGE achieves comparable results across the board. Notably, MAGE does not statistically significantly underperform compared to the other baselines on the considered datasets.
We clarify that Figure 2 in the manuscript is not generated using Equation (7). Equation (7) is utilized during the training phase to introduce stochastic noise, which helps prevent mode collapse. Meanwhile, Figure 2 illustrates the deterministic weights output by the aggregator during the testing phase, where all random noise is deactivated. Because the aggregator is a trainable subnetwork, the scale weights it outputs are the result of data-driven optimization for specific downstream tasks, rather than an artifact of the stochastic function chosen for training.
We acknowledge that the difference cannot be fully explained at present. Although both datasets involve motor imagery, they differ in channel configuration, task labels, cue design, and session structure. These factors may affect the temporal characteristics of the learned EEG patterns. One possible reason is that longer windows capture more stable mu/beta modulation, whereas shorter windows capture transient or cue-related activity, and the specific target classes of each dataset dictate which of these temporal features are most critical for classification. Therefore, the learned weights should be viewed as dataset setup-dependent preferences rather than universal properties of motor imagery.
We initially used a standard 1-second window like almost other foundation models, but found it too coarse for certain datasets. Specifically, on the FACED dataset, reducing the patch size obtained remarkable performance improvements, showing that this task relies on rapid, fine-grained temporal dynamics. In contrast, for sleep staging tasks like Sleep-EDFx, the 1-second window is sufficient for capturing slower, sustained brain activity. Therefore, we introduced the 250 ms and 500 ms patch sizes to better capture these high-frequency, localized signal variations required by certain tasks, while still maintaining a good balance with computational efficiency. Furthermore, we ablate alternative patch sizes in Figure 4 of the Appendix. These results demonstrate that our selected scales provide the good balance between model effectiveness and computational efficiency.
For single timescale in Table 2 of our manuscipt, we isolated specific scales by deactivating the modules for all other scales. For example, to evaluate the 500ms scale, only tokens with a 500ms patch size were processed to generate the output representation, while the other modules performed no computations. Consequently, the aggregator was bypassed entirely: the weight for the active scale was set to 1, and the weights for the inactive scales were set to 0.
MAGE-router provides greater adaptability than a fixed single scale. In MAGE-router, the aggregator first computes the weights for all available scales. Only the scale with the highest weight is activated, while the others are entirely deactivated. The goal of MAGE-router is to offer a version of MAGE that remains computationally comparable to a single-scale model with the only overhead coming from the aggregator computation. This allows the model to dynamically adapt to various downstream tasks, reducing the need for manual scale tuning.
We statistically compare MAGE against other multi-scale approaches, such as Medformer and a Uniform Weight baseline in the Table 5 of our manuscript. Our analysis shows that MAGE is significantly outperforms both baselines on the Sleep-EDFx dataset, while maintaining comparable performance across the remaining datasets. These results confirm that our adaptive aggregator not only guarantees stable baseline performance across various tasks but also provides a distinct, statistically significant advantage in specific applications, proving its value over fixed or alternative multi-scale strategies.
We have thoroughly proofread the entire manuscript to fix grammatical errors and improve overall clarity.
References:
[1] Fan, et al. "MSFNet: Multi-scale fusion network for brain-controlled speaker extraction." 2024.
[2] Fan, et al. "M3anet: Multi-scale and multi-modal alignment network for brain-assisted target speaker extraction." 2025.
[3] Li et al. "Mhanet: Multi-scale hybrid attention network for auditory attention detection." **2025.
[4] Feng, et al. "MSANET: Multi-Scale Semantic Aggregation Network for Brain-Assisted Speech Enhancement in Multi-Speaker Conditions." 2026.
[5] Fan, et al. "Dmf2mel: A dynamic multiscale fusion network for eeg-driven mel spectrogram reconstruction." 2025.
[6] Nadeau and Bengio. "Inference for the generalization error." 2003