- Rating
- 5
- Clarity
- 3
- Confidence
- 3
- Originality
- 2
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper introduces NeuroRVQ, a novel biosignal tokenizer designed for high-fidelity signal reconstruction. To preserve high-frequency details, NeuroRVQ decomposes biosignals using hierarchical Residual Vector Quantization (RVQ) codebooks and employs multi-scale temporal convolutions to capture information across various frequency ranges. By combining a multi-branch temporal RVQ mechanism with a novel phase loss function, which is absent in prior literature, NeuroRVQ achieves superior reconstruction performance compared to existing methods. Furthermore, the authors introduce NeuroRVQ-FM, a foundation model trained via a masked-token prediction objective. To isolate and validate the specific contributions of the tokenizer, the architecture of NeuroRVQ-FM is kept simple. Despite that, NeuroRVQ-FM still outperforms baseline models across multiple datasets on three biosignal modalities: EEG, EMG, and ECG.
Strengths and weaknesses
Strengths:
- The paper considers the multi-scale structure, an aspect often overlooked by existing models, which subsequently leads to a low-frequency bias.
- The novel phase loss effectively fills a critical gap in existing methods.
- The paper presents a comprehensive ablation study that clearly validates the architectural design choices.
Weaknesses:
-
There is a risk that the tokenizer might learn more subject-specific details and noise rather than robust representations. Although the authors have discussed this concern in the Discussion section, their claims do not have any theoretical or empirical support. While a larger or different codebook might yield better signal reconstruction, it does not guarantee superior performance on downstream tasks. The paper lacks a downstream task comparison with varying codebook sizes.
-
The evaluation relies on full fine-tuning experiments, which fails to definitively prove that the pre-trained representations are inherently beneficial since the entire network is trained during the downstream phase. Conducted experiments using linear probing would provide a much clearer assessment of the learned representations' quality.
-
The paper lacks a baseline comparison with a highly relevant work, CSBrain [1], which also utilizes multi-scale convolutional layers. A direct comparison with CSBrain is necessary to demonstrate the advantages of using discrete versus continuous embeddings.
Questions
-
Could the authors clarify how spatial information is handled? Channel dimension C carries critical information for biosignals. While the paper mentions the SE blocks, it also states that the multi-variate biosignal is represented by P patches of length w. It is unclear whether the channel dimension C is preserved throughout this process or not.
-
Have the authors analyzed the actual codebook utilization? It would be insightful to know if the model suffers from codebook collapse (only a fraction of the codebook is actively used) or if the codebook space is efficiently exploited.
-
Do the authors think it is possible to develop a unified tokenizer shared across multiple modalities? Since different biosignals often share some physiological information, it is worth exploring whether some first codebooks of the RVQ could capture domain-agnostic information.
Reference:
[1] Zhou, Yuchen, et al. "Csbrain: A cross-scale spatiotemporal brain foundation model for eeg decoding." Advances in Neural Information Processing Systems 38 (2026): 87150-87195.
Limitations
Yes
Paper formatting concerns
I haven't noticed any major issues in this paper with respect to violation of formatting, anonymity.
Final justification
The authors' explanations thoroughly address my concerns, particularly for codebook utilization and the linear probe results. Following the first rebuttal, I raised two follow-up questions concerning the significance tests for the linear probe results and the choice of downstream tasks during rebuttal. The authors have satisfactorily answered these additional questions as well. Therefore, I decide to increase my score from 4 to 5.
We thank the reviewer for their positive assessment and for recognizing the importance of our model's multi-scale structure and the novel phase loss. In the revised paper, we will add the results described below.
Channel Information
Channel information is preserved throughout the model. Consider the example of a 4-channel EEG signal with 2 seconds per channel. With a patch length of 1 second, the signal is split into 8 patches. Each patch retains its channel identity via two learned embeddings: a spatial embedding (SE), which tells the model which channel a patch comes from and a temporal embedding, which encodes its time position within the channel. The multi-scale encoder operates purely in the time domain and never mixes across channels. Cross-channel information is integrated in the transformer encoders, where self-attention operates over all patches.
Frozen-Backbone
We agree that frozen-backbone evaluation isolates representation quality. For every EEG model (we will run the EMG and ECG studies), we use the authors' original architecture (frozen) and weights, adding a trainable classification head to each architecture's features. For NeuroRVQ, we used all the tokens produced by the multi-branches as input to the linear layer. The results of classification-head-only training are shown below in the format of mean_bacc (std):
Codebook Utilization
Codebook utilization is an important property for RVQ-based tokenizer. Using the held-out validation sets per modality (EEG, ECG, EMG), we computed the following metrics across all branches (4 for all modalities) and RVQ levels (8 for EEG/ECG and 16 for EMG): utilization, perplexity, dead codes, top-1% mass (selection probability captured by the 1% most-used codes). For complete per-level analysis, please see our response to Reviewer EV4Y.
NeuroRVQ shows efficient code usage with no collapse: EEG and EMG reach 96.9% and 99.2% mean utilization with near-uniform usage and only 257 and 62 dead codes per 8192-entry codebook respectively. Within each modality the coarse first RVQ level has the lowest utilization while deeper residual levels saturate toward 100%, with perplexity increasing and top-code concentration decreasing monotonically with depth. This behavior is a residual hierarchy: first levels produce coarse details and successive levels encode progressively finer detail spread across the full codebook. ECG shows lower utilization (49.6%): this is expected and consistent with our scaling analysis (Section 4.2), which found that ECG's stereotyped spectrally simple morphology saturates with far fewer codebooks than EEG or EMG.
Reconstruction and downstream performance
In Appendix K, we have provided an analysis of two models LaBraM and NeuroRVQ-EEG where both models (as well as their corresponding tokenizers) are pre-trained and fine-tuned on the same datasets and with identical training and fine-tuning regimes. The results of Table 15 (the ERP task was added in the period between submission and the release of reviews) show that NeuroRVQ (which has a better quality tokenizer) achieves better downstream task performance:
Although LaBraM (5.8M) and NeuroRVQ-EEG (5.9M) share similar backbones (temporal encoders + transformers), they differ in the temporal encoder (LaBraM 1 branch vs NeuroRVQ 4) and in pre-training targets (1 vs 4×8 per masked token). So this analysis holds datasets, tokenizer training and pre-training/fine-tuning regimes identical, but the backbones differ slightly.
To examine the effect of same backbone, parameter budget, pretraining data, normalization and downstream protocol within the rebuttal time-frame, we designed the following ablation: We use two tokenizers from Appendix B Table 2 (EEG): Row 2 (4-Branch, 8CB, MSE Phase + MSE A) and Row 5 (4-Branch, 8CB, Phase Loss + log(A) + Temporal), which share the same architecture and differ only in the training loss (val MSE 0.946 and 0.035 respectively). We pre-trained two NeuroRVQ-EEG models on PhysioNet-MI using these two tokenizers and benchmarked both on the High Gamma Motor dataset. We chose Motor because the tokenizers and consequently the foundation models are pre-trained on PhysioNet-MI (a motor dataset), and Motor is the downstream task most closely matched to that pretraining domain. Evaluation is under head-only (10-fold) and full-finetuning (5-fold, due to compute constraints) subject-wise cross-validation. In other words, backbone architecture, parameter budget, pretraining data, normalization and downstream protocol are held identical. Only the tokenizer varies. The results show that tokenization quality translates into downstream performance: balanced accuracy improves with tokenizer fidelity and the effect is clearest under full fine-tuning.
We extended this ablation study to other tokenizers from Section 4.2 (Figure 2) in the EEG modality. To examine the relationship between number of codebooks and downstream performance, we used the tokenizers with (a) 4-Branch, 1CB (b) 4-Branch, 2CB and (c) 4-Branch, 8CB, which keeps the same architecture and training loss but scales only the number of codebooks.
We notice that once the tokenizer faithfully reconstructs task-relevant structure (motor in this case), further fidelity captures detail less relevant to the label with diminishing returns: a 10× MSE reduction (0.35→0.035) yields modest gain (saturation), whereas the low vs very good fidelity loss swap (0.946→0.035) gives a large 58.5→64.0. Under head-only probing the top tokenizers are indistinguishable (58.9–59.1, within across-fold std), while full fine-tuning separates them cleanly.
CSBrain
We thank the reviewer for pointing to this highly relevant model. We have added CSBrain as an EEG baseline in the revised Table 1. On the four EEG tasks completed so far it is competitive with other recent baselines (Motor 67.1, Sleep 57.0, Eyes 81.9). Its ERP (KU ERP) run is still completing and will be included in the camera-ready. CSBrain uses continuous cross-scale embeddings, whereas NeuroRVQ produces discrete tokens. We have added this discrete-vs-continuous distinction to the related-work discussion. We also note that we have strengthened Table 1: REVE was added to Table 1 in the period between submission and the release of reviews and we completed the BrainOmni comparison in the same period. Against this expanded and more competitive set, NeuroRVQ-EEG retains the best mean balanced accuracy (74.9).
Unified Tokenizer
This is an insightful future direction. The reviewer's intuition that the coarse first RVQ codebooks might capture domain-agnostic structure while deeper levels specialize is consistent with what we observe in the Codebook Utilization section above. A "shared-early / specialized-late" RVQ is therefore a plausible architecture for cross-modal sharing and we agree it is worth exploring. However, our Section 4 results suggest a single, fully shared tokenizer is unlikely to be optimal: the modalities differ substantially in sampling rate and spectro-temporal structure, which is why key hyperparameters (patch length, kernel sizes, RVQ depth) are tuned per modality (e.g. 8 RVQ levels for EEG/ECG vs. 16 for EMG) and why codebook usage differs. A one-size-fits-all configuration could be feasible only if reconstruction quality in some modalities is sacrificed. We therefore see the more promising path to unified biosignal modeling not as a single shared tokenizer, but as a set of modality-specific NeuroRVQ tokenizers feeding a shared foundation model. This is precisely why we designed NeuroRVQ as a modality-adaptive tokenizer family: to give the community a tool for building both stronger single-modality and future multi-modal biosignal foundation models. We will add this discussion to the revised paper.