- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 2
- Quality
- 3
- Significance
- 2
Read review
Summary
This paper introduces Hypnos, a multi-modal foundation model for overnight polysomnography (PSG) trained with a next-token prediction objective. Each of the eight physiological channels is independently tokenized using a residual vector quantization tokenizer, and then a RQ-Transformer is trained to autoregressively predict the next residual token jointly across all modalities. To support inference on arbitrary sensor subsets, the authors introduce a group-masking scheme in which modalities are randomly partitioned into attention groups, sampled from a Chinese Restaurant Process, per training example.
The model is pre-trained on over 20k PSG recordings from 9 public datasets. Evaluation uses frozen-encoder linear/MLP probes on sleep staging, arousal detection, apnea detection, and oxygen desaturation, across in-domain and held-out cohorts. The proposed Hypnos matches or exceeds prior sleep foundation models (SleepFM, OSF) and strong supervised baselines (U-Sleep, SleepTransformer, YASA) on most tasks. Empirical results also show that both next-token perplexity and downstream probe perfomance improve with model scale, and that the model retains useful performance under restricted-sensor configurations.
Strengths and weaknesses
Strengths:
-
Strong empirical results against relevant baselines. Hypnos embeddings outperforms the SOTA sleep foundation models, SleepFM and OSF, as well as task-specific supervised baselines on most of the datasets and tasks, with appropriate statistical testing showing significance. This demonstrates the proposed model produces high-quality, general-purpose sleep representations.
-
Thorough supplementary materials. The provided details in the appendix supports the reproducibility of the paper. It provides full prepocessing details, complete tokenizer and training hyperparameters, and compute accounting. It also contains substantive supporting experiments, including ablation of hyperparameter choices as well as scaling and stability analysis.
Weakness:
-
The paper's central claim about Next-Token Prediction is not verified. The motivation of the proposed method is that masked reconstruction objective is "poorly suited to the stochastic nature" of physiological signals and contrastive objective leave semantic invariance of physiological signals being poorly understood, whereas next-token prediction handles stochasticity gracefully. Yet no experiment isolates the training objective. The comparison agains baselines (e.g., SleepFM is contrastive and OSF is self-distillation) confound the objective with architecture, tokenization, model scale, context length, aggregation strategy, etc. The controlled experiments, e.g., hold other parts fixed and swap the next-token-prediction for a masked-reconstruction objective on the same discrete tokens, are not run. There's also no measurement showing that next-token prediction capture stochastic structure of physiological signals better than other alternatives. Thus, although the empirical results show that Hypnos is a good model, the stated claim about the advantage of next-token prediction is not supported.
-
Limited originality, with the novel component under-justified. The training and design recipe of the next-token prediction framework is adopted closely from prior works. The principal original component is therefore the grouped modality-masking scheme. However, group masking it not itself a new idea, prior work like LSM-2, wav2sleep, OSF already achieves missing-modality robustness through attention masking, zero-padding, or random channel dropout, thus the specific novelty here reduces to how the groups are samples. However, the Chinese Restaurant Process is not a obviously appropriate choice for partitioning a small, fixed set of 8 modalities. Its defining properties (e.g., unbounded cluster numbers, exchangeability) are not exploited in the sleep foundation model setting. There's no comparison agains simpler partition samplers, e.g., drawing a group count and then assigning modalities, so the reader cannot tell whether CRP's inductive bias matters at all. More importantly, the paper does not offer insights into how physiological modalities should be grouped, e.g., which sensor subsets are informative, or the interaction within which group are important for clinical deployment. The originality thus rests on a design choice that is neither motivated nor empirically validated.
Questions
-
Could you prove empirical results supporting that next-token prediction performs better than alternative objectives, e.g., masked-token-prediction, or capture the stochastic nature of physiological signals better than alternatives?
-
Could you validate the choice of the CRP grouping strategies, e.g., compare to simpler partition sampler with the architecture fixed?
-
What is the rationale for specific distribution over modality groupings the CRP induces (with )? How does it match clinically deployed sensor configuration?
-
Do you have explanations about why some baseline results are strikingly low for sleep stage, e.g., SleepFM got 0.418 on DOD-H and with MLP probe got even worse (0.370)?
Limitations
yes
Paper formatting concerns
None
Final justification
The rebuttal reveals some of the original methodological claims were too strong: NTP and masked-token prediction learn similarly effective representations, CRP offers no measured advantage over random dropout, and alternative pretraining methods are also scalable.
The paper’s contribution should therefore be framed as a strong large-scale demonstration of autoregressive token modeling for multimodal PSG, not as evidence that NTP uniquely enables scaling or that CRP uniquely enables missing-modality robustness. The generative capability remains only lightly evaluated and should be presented as a promising property rather than a fully validated contribution.
I retain my slightly positive rating because the work provides strong large-scale empirical demonstration. I would also consider rejection defensible if the AC places greater weight on the limited methodological novelty, the negative results for the claimed CRP contribution, or the fact that several central claims required substantial revision during rebuttal.
Meta-review
The paper propose a next-token-prediction sleep foundation model with a Chinese Restaurant Process modality-masking scheme, evaluated across diverse downstream tasks and model scales. Reviewers agreed the empirical results are strong, where the model outperforms SleepFM and OSF on most tasks with appropriate statistical testing, the model is robust to missing modalities, three model sizes are provided for different compute budgets, and the supplementary materials are thorough and support reproducibility.
However, all three reviewers converge on the same core gap: the paper’s central claims about why NTP works are asserted, not isolated experimentally. The following points must be addressed especially:
All three reviews independently note that the comparison against SleepFM (contrastive) and OSF (self-distillation) confounds the training objective with backbone, context length, and aggregation strategy. Run a controlled ablation that fixes the backbone and tokenization and swaps NTP for a masked-reconstruction objective on the same discrete tokens. Without this, the paper’s motivating claim, that NTP handles the stochastic nature of physiological signals better than MAE/CL, is not supported by the current evidence.
Missing-modality robustness via masking is not new, so CRP’s specific contribution is the grouping strategy. Compare against a simpler partition sampler to establish whether CRP’s inductive bias is actually doing work, given its defining properties are not obviously suited to a small fixed set of modalities.
Report parameter counts and/or compute for Hypnos and baselines, and clarify whether reported gains come from a better learned representation or simply a larger model. At minimum, state clearly that the current results show “this model scales” and temper any claim that NTP scales better than alternatives, unless a compute-matched comparison is added.