- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
The paper studies automated generation of structured clinical EEG reports from long-duration EEG recordings. It introduces CELM, an EEG-to-language model that converts hour-scale, multi-channel EEG signals into compact epoch-level representations, applies sequence-aware alignment to map EEG representations into a language model input space, and then uses prompt-conditioned generation to produce clinical report sections. The authors also construct a paired EEG-report benchmark from clinical EEG recordings and reports, including automated structuring of report sections such as EEG findings, background activity, epileptiform abnormalities, events/seizures, and impressions. They evaluate CELM against text-only, handcrafted EEG-feature, and multimodal projection baselines across two hospital sites, and report improvements using automatic metrics, qualitative clinical analysis, ablation studies, zero-context generation, and expert evaluation.
Strengths and weaknesses
Strengths.
- The application is important and well-motivated. Clinical EEG report writing is labor-intensive and requires expert interpretation of long, high-frequency, multi-channel signals. This is a setting where standard LLMs and conventional multimodal architectures face clear context-length and alignment challenges.
- The proposed modeling choices are sensible for the application. Epoch-aggregated tokenization is a practical way to reduce the scale of hour-long EEG recordings, and sequence-aware alignment is better matched to EEG than a naive linear projector. The ablation results support the claim that modeling temporal dependencies before projection is useful.
- The benchmark construction is potentially valuable for the community, since structured EEG-report pairs are scarce and existing EEG foundation models are mostly designed for discriminative tasks rather than report generation.
- The authors go beyond lexical metrics by including qualitative clinical dimensions and human expert evaluation, which is particularly important because BLEU/ROUGE/METEOR alone are weak indicators of clinical correctness.
Weakness
-
The largest concern is whether the generated reports are truly grounded in the EEG signal rather than in report priors, site-specific reporting conventions, or clinical-context shortcuts. The zero-context experiment helps, but stronger controls would be valuable. For example, shuffled EEG-report pairs, temporally corrupted EEG, mismatched clinical context, and cross-site train/test experiments would better isolate the causal contribution of the EEG input. Since clinical reports often contain stereotyped language and institution-specific structure, this type of control is important for a use-inspired clinical paper.
-
The paper relies on automated section detection and local LLM-based extraction/normalization to structure clinical reports. This is a reasonable engineering choice, but the benchmark itself is a central contribution, and I did not find enough evidence that the structuring pipeline has been validated against manual annotations. Errors in section extraction, omitted findings, or leakage across report sections could affect both training and evaluation. A manual audit of the structured reports, with inter-annotator agreement or section-level extraction accuracy, would substantially strengthen the paper.
-
The human expert evaluation is a strength, but it appears limited relative to the diversity of EEG abnormalities and reporting styles. The paper also notes an important failure mode: CELM can misclassify mildly abnormal EEG recordings as normal, even when they exhibit abnormal signal patterns. This is clinically significant and should receive more detailed analysis. I would like to see error breakdowns by normal vs. mildly abnormal vs. clearly abnormal recordings, epileptiform abnormalities, seizure/event cases, focal/lateralized abnormalities, and rare findings. For a clinical report generation system, missing an abnormality is more consequential than a minor lexical mismatch.
-
The terminology around “foundation model” is somewhat overstated. Since the EEG encoder and LLM appear to remain frozen, and training primarily updates the alignment module, CELM seems closer to an EEG-language adapter/alignment framework built on pretrained foundation models than to a newly trained foundation model. The authors should clarify this framing and moderate claims where appropriate.
-
The significance depends heavily on the validity of the benchmark construction and on demonstrating that the model is robustly grounded in EEG signals across sites and patient populations. Stronger external or cross-site validation would improve confidence in the practical impact.
The authors include a limitations/broader impact discussion in the appendix/checklist, but I did not find an explicit reference to these sections in the main text; adding a short limitations/ethics paragraph or a pointer in the main paper would improve transparency.
Questions
- Could the authors add a cross-site evaluation, such as training on S0001 and testing on S0002, or at least report performance stratified by site and visit type? This would clarify whether the model generalizes beyond site-specific reporting conventions.
- The reported gains of CELM over the strongest baselines are large. Can the authors comment on which component they believe accounts for most of the improvement: epoch-aggregated tokenization, sequence-aware alignment, clinical-context conditioning, or the choice of base LLM/EEG encoder?
- In the human expert study, how were the 20 cases selected, and were experts blinded to model identity and case source? Clarifying the sampling and blinding protocol would help interpret the strength of the clinical evaluation. This is important to add to the main paper.
- How sensitive are the results to EEG recording duration and number of epochs? For example, does performance degrade during longer or shorter sessions, or with recordings near the 10,000-second filtering threshold?
- What is the intended clinical workflow for CELM: drafting full reports, assisting section-level report writing, triaging abnormal studies, or supporting retrospective research? Please clarify what level of human review is assumed.
- For the expert evaluation, what clinical expertise did the six evaluators have, and were clinicians and BME researchers analyzed separately? This would help interpret the “real-world readiness” ratings.
- How are clinically serious errors defined in this setting? For example, do the authors distinguish between minor wording differences, missed mild slowing, missed epileptiform activity, wrong lateralization, and hallucinated seizures? This information is not present.
Limitations
No, not in the main paper. The paper acknowledges some technical limitations, such as weaker performance on mildly abnormal cases and the compression/performance trade-off, but it does not adequately discuss the broader limitations and implications of deploying automated clinical EEG report generation. The authors should add a dedicated limitations/ethics discussion covering data-use approval, consent or waiver of consent, privacy safeguards, restrictions on benchmark/model release, risks of hallucinated or missed abnormalities, the need for neurologist oversight, and limited generalization beyond the two hospital sites studied.
Paper formatting concerns
The submitted PDF itself is anonymized, but I noticed a possible anonymity/disclosure issue.
The abstract states that the model and benchmark construction pipeline are released at an anonymous repository URL. Separately, public external materials appear to indicate that a version of this work was released as an arXiv preprint and accepted to the ICLR 2026 Workshop on Multimodal Intelligence, with code also released publicly. This may be compatible with NeurIPS policy if the workshop version is non-archival, and I have not adjusted my score based on this issue. However, I recommend that the AC/PC verify whether the linked repository preserves anonymity and whether any required prior dissemination or disclosure of a workshop version was made.
ICLR 2026 workshop published link: https://openreview.net/forum?id=OgSSKlnfBQ Github link publicly available with the same title: https://github.com/Jathurshan0330/CELM
I did not find a clear ethics statement addressing IRB/consent, privacy safeguards, or clinical deployment risks, despite the paper using clinical EEG data and generating clinical reports.
We thank the reviewer for the thoughtful feedback. We appreciate your recognition of this important application, the practical modeling choices, the potential value of the benchmark to the community, and the inclusion of evaluation beyond lexical metrics through qualitative analysis and human expert evaluation.
(1) Mismatch Control: Each test EEG recording is paired with a randomly selected report from a different patient, using the same trained CELM with no retraining. If CELM grounds on EEG, performance should degrade significantly when the EEG and ground truth report describe different patients.
The ~40% drop across all metrics confirms that CELM is grounded on EEG recordings rather than simply learning institution-specific report-template priors.
(2) Temporally Corrupted EEG control: Three signal corruption modes are applied at inference to test whether CELM relies on temporal structure within the EEG, (a) random permutation of epoch order, (b) replacement with Gaussian noise matched to the signal's statistics, and (c) repetition of a single randomly selected epoch across the full recording length.
The consistent ~34% degradation across all corruption modes confirms that CELM is sensitive to both the content and temporal ordering of the EEG signal. Further validating that CELM is grounded on CELM is grounded on input EEG recordings.
(3) Channel Permutation Control: EEG channels are randomly shuffled across the montage. This tests whether CELM is sensitive to spatial channel arrangement.
~32% drop across all metrics indicates that spatial channel information is meaningfully utilized by the model and that CELM is sensitive to channel arrangements in the input. This is an important property for lateralization (Figure 4). We also computed and conducted statistical testing for all reported metrics, where the degradation for all control experiments are significant (results and analysis will be included in the revised manuscript).
Additionally, we conducted cross-site evaluation, and the results are as follows:
There is performance degradation in the cross-site setting but does not collapse, suggesting that CELM learns transferable EEG representations while also partially capturing site-specific reporting conventions. This is expected given the differences in visit types and report structures between S0001 and S0002 (Section 5 Datasets, Appendix A). We will include all the control and cross-site results in the revised manuscript. We thank the reviewer for these suggestions, which have substantially strengthened our evaluation and evidence for EEG signal grounding.
Please refer to our response to W1 for the cross-site evaluation results, which we will include in the revised manuscript.
We thank the reviewer for this question. Based on our ablations, the sequence-aware alignment module contributes the most. The alignment ablation (Section 5.5, Figure 6) shows that replacing SCA with a linear projector (as in LLaVA) or Perceiver projector leads to performance drops and training instability (overfitting), while both SCA and SCC converge stably. The EEG encoder in epoch-aggregated tokenization also plays an important role. According to our encoder ablation (Appendix D.4, Table 11) shows CBraMod consistently outperforms LaBraM, indicating that higher-quality EEG representations translate directly to better report generation. Additionally, epoch-aggregated tokenization makes EEG–language modeling computationally feasible by allowing long recordings to fit within the context limits of existing open-source LLMs.
The 20 cases were randomly sampled from the test set across both sites. Experts were fully blinded, where each case presented the ground-truth report alongside three anonymized generated reports (from two baseline categories and CELM) without revealing model identity or order. We have mentioned these details in Section 5.4 and will further clarify the sampling and blinding protocol in the revised manuscript.
We evaluated CELM’s performance across recording durations at both sites. For S0001, correlations between duration and performance were weak and mostly non-significant (Spearman ρ = −0.02 to −0.07), with generally stable results across duration quartiles and only a modest decline for the longest recordings (ROUGE-1: 0.55, 0.59, 0.56, 0.52). For S0002, performance showed a weak positive correlation with duration (ρ = 0.14 to 0.26, p < 0.001), improving from the first to the second quartile before plateauing (ROUGE-1: 0.55, 0.66, 0.68, 0.68).
CELM is designed as a clinical drafting assistant that generates structured report drafts for neurologists to review, edit, and finalize. Through prompt conditioning, it supports both full-report and section-level generation (Section 4.4). It is intended to assist clinicians, not to produce autonomous final reports.
The six evaluators comprised clinicians and BME researchers with expertise in clinical EEG interpretation, EEG signal analysis, and neurophysiology. Their ratings were analyzed jointly in the current manuscript.
In the manual qualitative analysis (Section 5.3, Figure 4), we focused on error types across four clinically relevant dimensions, including abnormality prediction (normal/abnormal misclassification), lateralization (wrong hemisphere), spectral dynamics (incorrect frequency characterization), and epileptiform abnormalities (missed or incorrect epileptiform activity). These dimensions describe the EEG recordings, which are important for clinical interpretations. During the analysis, we focused on the contextual accuracy of clinical findings rather than minor wording differences.
We thank the reviewer for the suggestion and will revise the terminology and moderate the corresponding claims the manuscript.
For EEG signal grounding, our control experiments including mismatch, temporal corruption, and channel permutation demonstrate statistically significant performance degradation, confirming that CELM is grounded on EEG recording input. Additionally, we conducted cross-site evaluation (see our response to W1). Evaluation beyond the Harvard dataset is important. However, publicly available paired EEG–report datasets are currently lacking. By releasing this large-scale benchmark and an automated structuring pipeline, we address this challenge and hope it will enable the generation of more EEG-report benchmarks.