- Rating
- 5
- Clarity
- 3
- Confidence
- 5
- Originality
- 3
- Quality
- 3
- Significance
- 4
Read review
Summary
The authors present DeepArrhythmia. DeepArrhythmia improves beat-level arrhythmia classification by predicting each R-peak-aligned beat inside a longer ECG segment instead of looking at isolated beat crops. This lets the model use both the shape of the beat itself and the surrounding rhythm context. It also uses agents with tools to extract useful evidence, such as detected peaks, rhythm measurements, morphology measurements, and short textual descriptions, making the prediction process easier to interpret. Finally, it does not use all extra evidence for every case; instead, it uses confidence to decide when more evidence is needed, helping difficult cases while avoiding unnecessary noise or cost for easier ones.
Strengths and weaknesses
Strengths
- The authors address an important problem in utilizing AI for arrhythmia detection.
- DeepArrhythmia is a novel framework that provides interpretability by using the outputs from multiple modular tools to ground its final prediction.
- The method is technically sound and validated with comprehensive experiments.
- The figure and paper is easy to follow.
- The experiments on augmented and perturbations of the data are well appreciated.
Weaknesses
- As the authors have acknowledged, the pipeline seems to be heavily influenced by the data: 1) has poor cross-dataset generalization and 2) poor generalization to rare classes. A question I have here then is how does DeepArrhythmia compare in these 2 limitations with other baselines? It would be important to see this comparison.
- The pipeline seems to be quite expensive and hand-engineered, compared to other baselines such as SVM, which are much simpler and competitive in performance.
- I am curious on how the performance of DeepArrhythmia compares to other baseline models under balanced class distributions for both training and testing. This would give more insight on DeepArrhythmia's performance compared to other baselines.
- As the performances are not overwhelmingly better than previous baselines as well as quite volatile across each dataset, it would be important to see the statistical significance of the results.
Questions
- For the faithfulness evaluation (Appendix M), what was the dataset and the distribution used to conduct the experiment?
- Why have the authors not tried on perhaps two of the most famous ECG datasets, PTB-XL and MIMIC-IV ECG? I would hope to see performances on at least PTB-XL, as MIMIC-IV ECG is quite large. I am curious on why the authors chose not to include these two datasets.
Limitations
yes
Paper formatting concerns
na
Final justification
The authors have sufficiently added relevant experiments and answered my questions. I have adjusted my review accordingly.
W1 — Comparison with baselines on cross-dataset and rare-class generalization.
We add both comparisons under an identical protocol. Cross-dataset: averaged over the 12 off-diagonal train/test transfers, DeepArrhythmia degrades far less than the baselines (mean Micro-F1 0.70 vs 0.46 for the 1D ResNet). Its failure mode also differs from the SVM's: the SVM systematically collapses to the majority (normal) class off-diagonal, losing all abnormal-beat detection (Macro-F1 0.65 → 0.29), whereas DeepArrhythmia retains abnormal detection on most transfers; its worst case is confined to the VitalDB-trained direction (the most dissimilar acquisition), where it over-predicts a single abnormal class — the same VitalDB outlier degrades all methods. Rare classes: per-class F1 (Table 12) shows DeepArrhythmia is highest on every abnormal class on MIT-BIH (S 0.392 vs SVM 0.206 vs ResNet 0.073; F 0.066 vs 0.025 vs 0.040). Crucially, because DeepArrhythmia grounds each decision in explicit peak, rhythm, and morphology evidence, these failures are diagnosable — one can inspect the numerical features and textual morphology behind a wrong prediction — whereas the SVM and ResNet offer no such insight.
W2 — Cost / hand-engineering vs. a simple SVM.
The SVM is simpler and in-domain competitive, but it is a black box that does not generalize: it collapses to majority-class prediction under cross-dataset shift (see W1) and, by construction, produces only a class label with no supporting evidence. DeepArrhythmia's additional cost buys three things a simple classifier cannot provide. (i) Interpretability: every prediction is grounded in explicit, auditable evidence — detected peaks, numerical rhythm/morphology measurements, and a textual morphology analysis — and this evidence is verified to be causally used, not decorative: an evidence-deletion test (Table 13) shows that disrupting the exact cue an explanation cites collapses accuracy from 92.5% to 1.9%, and cardiologists rate the analyses as clinically valid (Table 4). This auditability is essential for a clinical decision-support setting and makes even error cases inspectable. (ii) Better cross-dataset robustness (W1). (iii) Efficiency via confidence-guided routing, which invokes the expensive tools on only a minority of segments. We also note the method's accuracy does not depend on the heaviest component: even without the Morphology Analyzer (numerical features only), DeepArrhythmia already exceeds the SVM (Macro-F1 0.5694 vs 0.523).
W3 — Performance under a balanced class distribution.
Macro-F1, our primary metric, already weights all classes equally. Adding a balanced metric (balanced accuracy = mean per-class recall) on MIT-BIH gives DeepArrhythmia 0.568 vs SVM 0.516 vs 1D ResNet 0.449, so the ordering is preserved under class-balanced evaluation. (Balanced re-training would require retraining all models; we are happy to add it if preferred.)
W4 — Statistical significance.
We add 95% bootstrap confidence intervals on MIT-BIH Macro-F1: DeepArrhythmia 0.593 [0.583, 0.603], SVM 0.523 [0.516, 0.530], 1D ResNet 0.362 [0.356, 0.367]. The intervals are non-overlapping, so DeepArrhythmia's improvement is statistically significant; the ML/DL baselines in Table 1 are additionally averaged over three seeds.
Q1 — Dataset/distribution used for the faithfulness evaluation (Appendix M).
The evidence-deletion test (Table 13) is conducted on the MIT-BIH test set, on 160 beats whose explanations cite a specific morphological cue, stratified by cue type (QRS 53, P-wave 54, RR 53). We will state this explicitly in the revision.
Q2 — Why not PTB-XL and MIMIC-IV ECG?
These are excellent resources but target a different task: they provide record-level, 12-lead diagnostic-statement labels, not the per-beat AAMI (N/S/V/F) annotations required for beat-level arrhythmia classification. The four datasets we use were chosen precisely because they carry beat-level annotations under subject-disjoint splits. The framework's components do transfer to record-level 12-lead classification (we apply them to PTB-XL superclasses in related work), but that is outside the beat-level scope of this paper.