- Rating
- 5
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper proposes tPoE-EIB, a constrained downstream head for adapting the frozen EEG foundation models in diagnostic tasks. The main idea is to make the selected evidence part of the forward prediction path. The method is composed by an evidence-bottleneck objective, a calibration argument for tempering correlated experts, and several intervention-based audits of gate faithfulness and expert reliance. Experiments on TUAB, TUEV, TUSZ, and three private clinical cohorts validate the effectiveness while giving a more inspectable decision path.
Strengths and weaknesses
Strengths
- The core framing is clear, the interpretability of the EEG foundation model is made into an intrinsic architectural constraint, rather than a post-hoc interpretation.
- The theory is closely tied to the method, although this paper does not emphasize their theoretical contributions, several proofs are apt and useful.
- The experimental scope is broad, covering six diagnostic tasks across public TUH benchmarks and private clinical cohorts, with both sparse and dense montage settings.
Weaknesses
- The benefit of tempering is not fully consistent, as untempered PoE outperforms or matches the learnable-alpha model on some dense-channel tasks where the correlation argument should matter most, author need to discuss this in more detail.
- The auditability claim is still internally defined, I feel a bit overstated. With no clinician study or expert-annotation benchmark beyond literature-derived regional priors.
- The marginal temporal/channel gates cannot directly represent localized spatiotemporal evidence, which is a serious limitation for focal EEG phenomena such as seizures.
- Some audit quantities, especially posterior reliance and (D_{\mathrm{SKL}}), are reported without uncertainty estimates and sometimes on scales that are hard to interpret, I don’t really understand why they are several thousand. Please provide the normalized value.
Questions
Presentation issues: Fig3 ‘s caption duplicates much of the text from appendix H.9. The fonts in fig2 and fig4 (in appendix) are too small to be seen by the naked eye. Reference style inconsistent somewhere, eg. In [4,5], author wrote “ICLR”, but in [3,4,17] wrote the full name “ International Conference On Learning Representations”. And also, some page ranges are present, most of the references does not. Some notions need to check. Eg. Eq. 4 uses , Tab.5 uses , need to clarify the relationship between them. At Tab.1’s caption, states “second best is underlined”, but not everywhere.
- The benefit of tempering is not fully consistent, as untempered PoE outperforms or matches the learnable-alpha model on some dense-channel tasks where the correlation argument should matter most, author need to discuss this in more detail.
- The auditability claim is still internally defined, I feel a bit overstated. With no clinician study or expert-annotation benchmark beyond literature-derived regional priors.
- The marginal temporal/channel gates cannot directly represent localized spatiotemporal evidence, which is a serious limitation for focal EEG phenomena such as seizures.
- Some audit quantities, especially posterior reliance and (D_{\mathrm{SKL}}), are reported without uncertainty estimates and sometimes on scales that are hard to interpret, I don’t really understand why they are several thousand. Please provide the normalized value. The learned are not reported per task and seed, and the empirical temporal–channel expert correlation is not measured, so the central prediction of Proposition 2 is never empirically validated. For insertion–deletion, the authors don’t provide what exact masking strategy is used. For the private Depression and Cerebrovascular cohorts, the authors didn’t provide any basic confound check.
- Lack comparison with some related work. Relevant comparators for intrinsic evidence paths like Gumbel-softmax; topology-aware interpretable EEG method like EEG-SeeGraph; spatial PEFT method for EEG foundation model like EGA; and evidence-constrained decisions work like Tree-of-evidence. Them should be compared or discussed. Maddison, Mnih & Teh (2017), The Concrete Distribution: A Continuous Relaxation of Discrete Random Variables, ICLR 2017(arXiv:1611.00712) Strypsteen, Thomas, and Alexander Bertrand. "End-to-end learnable EEG channel selection for deep neural networks with Gumbel-softmax." Journal of Neural Engineering 18.4 (2021): 0460a9. Wu, F., Song, Z., Xu, G., Hu, K., Wang, Z., Guo, Y., & Zhang, Z. (2026, May). EEG-SeeGraph: Interpreting functional connectivity disruptions in dementias via sparse-explanatory dynamic EEG-graph learning. In ICASSP 2026-2026 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP) (pp. 6996-7000). IEEE. Nnamdi, M. C., Marteau, B. L., Zhong, Y., Tamo, J. B., & Wang, M. D. (2026). Tree-of-Evidence: Efficient" System 2" Search for Faithful Multimodal Grounding. arXiv preprint arXiv:2604.07692.
Limitations
The paper already discusses several limitations, like the inability of marginal gates to model joint time-channel patterns, the weakness of group-level audits when gates are uniform or patient-specific, and the fact that the bottleneck does not guarantee clinical correctness, I totally agree with these points. But I think still two limitations should be made more visible in the main text:
- The private clinical cohorts lack formal demographic, site, montage, device, or medication confounding audits;
- The auditability claim is based on internal/intervention consistency rather than clinician validation. These issues do not undermine the method, but they limit how strongly the clinical evidence claims should be interpreted.
Paper formatting concerns
N/A
Meta-review
[Summary & Strengths] This paper proposes tPoE-EIB, an adaptation head for frozen EEG foundation models that replaces downstream classifiers with a rate-limited, evidence-only bottleneck using temporal and spatial Gaussian experts. Across public TUH benchmarks and private clinical cohorts, the authors show that tPoE-EIB maintains competitive diagnostic accuracy while offering significantly better forward-path auditability and selection faithfulness than post-hoc explanation methods. The formulation is theoretically grounded and the evaluation protocol is comprehensive.
[Main Weaknesses & Guidance for Rebuttal] All three reviewers (Reviewer X2P1, Reviewer EvGw, Reviewer 4ue1) appreciate the intrinsic interpretability framing, but raise key concerns regarding empirical gains, theoretical assumptions, and clinical validity: