- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 2
- Quality
- 2
- Significance
- 3
Read review
Summary
This paper introduces CORTEG, a cross-modality transfer framework that adapts a pretrained scalp-EEG foundation model (ST-EEGFormer) to intracranial ECoG decoding. The approach rests on three contributions: (i) a KNNSoftFourier spatial adapter that maps ECoG electrode coordinates into the EEG channel embedding codebook, eliminating the need to retrain the model backbone; (ii) a dual-stream tokenizer that separates low-frequency (1–64 Hz) and high-gamma (70–200 Hz) signals so each can be encoded with modality-appropriate spectral resolution; and (iii) a two-stage LOO-FT deployment strategy that calibrates a new patient in 10–30 minutes on a single GPU. Together, these components address the central deployment bottleneck in intracranial BCI.
Strengths and weaknesses
Strength:
- Systematic study of an under-explored transfer problem. CORTEG is the first systematic study of scalp-EEG → ECoG transfer for a foundation-model-based decoder. The authors provide a rich set of baselines: per-subject decoders, population-trained from-scratch models, and ablations against alternative foundation-model backbones
- Well-motivated spatial adapter design. The KNNSoftFourier spatial adapter follows a clear domain-knowledge prior: ECoG electrodes near EEG electrodes should be encoded similarly. This inductive bias is well-justified by neuroanatomy and explains the model's behavior at initialization: the soft attention mass spreads over the spatially nearest EEG channels, then concentrates on a dominant channel after training.
- Mechanistic interpretability through manifold analysis. The manifold-alignment analysis provides a mechanistic account of why transfer works: the cross-modality representations occupy the same geometric structure after spatial adaptation.
Weakness:
- Transfer signal is task-dependent. The cross-modality pretraining benefit is large on the audio task but modest on the finger task. The discussion about why the audio modality benefits more from the scalp-EEG prior, and whether this reflects differences in signal structure is missing.
- Small datasets and long per-patient calibration limit clinical utility. The finger task uses n = 9 subjects and the audio task uses n = 16 subjects, with the audio dataset held privately by the authors. Even with LOO-FT reducing training to 10–30 minutes per patient, this is still long for clinical deployment.
- Limited reproducibility. No anonymized assets or URL were provided.
- channel in fig 4 for s8 position seems far away from cortex, is that correct?
Questions
- High-gamma stream design lacks justification. The dual-stream tokenizer separates LFS (1–64 Hz) and HGA (70–200 Hz) into independent token streams, but the paper does not verify the design intuition. Why averaged with the encoder-processed low-stream tokens?
- Task scope is narrow. ECoG decoding supports a wide range of clinically meaningful classification tasks — seizure detection, speech decoding, error-related potentials, motor imagery. The paper restricts evaluation to finger flexion regression and auditory envelope regression. Why is this aim for?
- The paper claims ST-EEGFormer is "uniquely well-suited" because of its channel codebook. A controlled experiment is needed: train ST-EEGFormer with a randomly-initialized channel codebook like table 2. Table 2 Random init (no pretrain) full-FT + adapter with what model backbone?
- Does the lack of scaling indicate limited ECoG data, architectural mismatch, over-regularized LoRA adaptation, or that scalp-EEG pretraining does not scale cleanly to ECoG?
Limitations
yes
Paper formatting concerns
No anonymized assets or URL were provided.
Final justification
The rebuttal addresses my main concerns through the new comparisons with intracranial foundation models and the public BrainTreebank experiment, which provide stronger evidence for the proposed cross-modality transfer. These additions materially improve my assessment of the paper. However, I expect the new experiments to be fully incorporated into the final manuscript with complete methodological and statistical details. The authors should also release the code and configurations as stated and address the remaining limitations and clarifications raised during the review. Based on the rebuttal and these commitments, I have raised my score.
Response to Reviewer NvGg
Thank you for the careful review. We address each concern below.
Weakness 1 — Why is the transfer benefit task-dependent?
We agree that the original discussion did not sufficiently explain the difference between the two tasks. EEG pretraining provides little benefit for high-gamma-dominant finger decoding but a substantial benefit for low-frequency-dominant auditory decoding. A plausible explanation is that scalp-EEG pretraining better captures transferable low-frequency structure, whereas finger decoding depends more strongly on focal high-gamma activity. We will revise the paper to make this task-dependent interpretation explicit.
Thus, EEG pretraining should not be expected to improve every downstream task; its value depends on alignment between the pretrained representation and the target signal structure. CORTEG addresses this limitation through a dedicated high-gamma pathway alongside the pretrained low-frequency representation. On finger decoding, this design remains competitive with task-specific methods and achieves the highest mean performance.
Weakness 2 — Small datasets, private auditory data, and clinical calibration
We acknowledge the limited sample sizes of the original datasets and that the private auditory data limit independent verification. We therefore added a fully public BrainTreebank sEEG sentence-onset experiment. Under a matched three-seed comparison, EEG-pretrained CORTEG reaches 0.699 AUROC versus 0.595 for random initialization, improving all subjects (Wilcoxon p=0.0156). This does not replicate the original ECoG regression tasks, but provides reproducible evidence that the transfer benefit extends to another intracranial modality and task.
We also agree that CORTEG is not a zero-calibration clinical system. Stage 2 uses approximately 10–30 minutes of patient data and 10–30 minutes of adaptation on one RTX 5090; zero-shot performance remains weak. Its current advantage is parameter-efficient reuse of cross-subject data rather than immediate deployment. Reducing calibration requirements remains important future work.
Weakness 3 — Reproducibility
To address the reproducibility concern, we have prepared the implementation, configurations, preprocessing pipeline, and data-access statement for release upon acceptance. NeurIPS policy prevents us from including external URLs in the rebuttal, but if venue rules permit, we would also provide confidential access to an anonymized repository through an official channel during the rebuttal period.
Figure 4 — S8 electrode position
The original Stanford coordinate is valid and is used unchanged before spatial transformation. Subject 8 has a larger head relative to the displayed fsaverage template, so normalization and two-dimensional projection create a small apparent displacement outside the cortical boundary. This is a visualization artifact and does not affect the model input.
Question 1 — Justification of the high-gamma stream and fusion strategy
The design follows the signal structure of the task: the pretrained EEG representation is strongest at low frequencies [1], whereas high-gamma activity is particularly informative for finger decoding [2]. We therefore combine the pretrained low-frequency pathway with a dedicated high-gamma stream.
We evaluated multiple fusion depths and more complex alternatives, including unsuccessful variants reported in
Appendix Table 10. Simple mean fusion was the strongest and most consistent, while remaining parameter-free and less prone to overfitting. We additionally evaluated layer-wise gated fusion, which improves Finger-Base and Audio-Base/Large but degrades Audio-Small. We therefore retain mean fusion as the default and report gated fusion as an optional alternative that avoids a separate depth sweep.Question 2 — Why restrict the task scope to finger and auditory regression?
Our initial question was whether a pretrained scalp-EEG model could be adapted to continuous intracranial decoding. Finger-trajectory prediction is a challenging multidimensional regression task for which the best decoders remain compact and participant-specific. After obtaining strong finger results, we added auditory-envelope regression to test a different task. CORTEG performs well in both, suggesting that it is not restricted to only one task.
Now, we further added BrainTreebank sentence-onset classification using public sEEG data, where pretrained CORTEG again outperforms random initialization. Together, the finger, auditory, and BrainTreebank experiments provide an initial feasibility study across two intracranial modalities, regression and classification, and different signal characteristics. We do not claim comprehensive coverage, and we believe that broader evaluation remains future work.
We have now further extended the evaluation to the fully public BrainTreebank dataset, using a sentence-onset classification task with stereo-EEG recordings (another modality). CORTEG again showed a clear benefit from EEG-pretrained initialization, providing additional evidence that the approach can transfer across different intracranial modalities, task formulations, and signal characteristics.
To summarize, our aim is not to claim comprehensive coverage of intracranial decoding, which is too ambitious. However, we believe that the finger, auditory-envelope, and BrainTreebank experiments together provide an initial feasibility study showing that a pretrained scalp-EEG model can be adapted to multiple intracranial decoding settings. Broader validation across seizure detection, speech production, error-related potentials, motor imagery, and other tasks remains important future work.
Question 3 — Channel-codebook control and the random-initialized backbone
The reviewer is correct that describing ST-EEGFormer as “uniquely well-suited” based on its pretrained channel codebook was too strong. New controlled ablations show that the exact codebook vectors are not the main source of benefit:
The MAE-trained channel embeddings act as distinct tokens rather than carrying specific semantic channel information. At transfer time, our adapter supplies the geometric prior by using ECoG coordinates and known EEG locations to construct inputs through KNN interpolation.
Shuffling or synthesizing the codebook changes performance by at most 0.003, whereas replacing the geometry-conditioned adapter with an MLP or removing it reduces performance by 0.037–0.052. Randomizing or zeroing ECoG coordinates reduces performance by 0.075 and 0.318, respectively. On BrainTreebank, coordinate shuffling reduces AUROC to 0.508. These results support the importance of the geometry-conditioned interface rather than the exact pretrained codebook content. We will revise the claim accordingly.
For the second part of Q3, the Stanford “random initialization” control uses the same ST-EEGFormer-S architecture as the baseline Full CORTEG-S (LoRA + KNNSoftFourier adapter).
Question 4 — Interpretation of the scaling plateau
We share the reviewer’s interpretation that the observed plateau does not support a beneficial model-scaling trend. The plateau could reflect limited ECoG data, architectural mismatch, the LoRA budget, or weak alignment between scalp-EEG pretraining and the target task, and our current experiments cannot distinguish these explanations.
This question also remains open more broadly. On continuous finger decoding, the strongest existing methods are still compact, task- and participant-specific models, and our additional experiments show that current intracranial foundation models do not transfer competitively to this task under the evaluated protocols. More generally, recent EEG-foundation-model benchmarks report mixed scaling behavior, with larger pretrained models sometimes failing to outperform compact neural networks. Therefore, increasing backbone size alone should not be assumed to improve downstream performance [3-5].
Our results instead suggest that data scaling may be a more promising direction than model scaling in the current setting. Pooled cross-subject training consistently benefits performance, indicating that a larger and more diverse Stage-1 population dataset could improve generalization to new patients. However, we have not yet conducted a controlled study that independently varies pretraining-data volume, population-training data, model size, and adaptation capacity. We will therefore present the observed plateau as an unresolved limitation and treat data scaling as a promising hypothesis for future work.
References
[1]Sun, Qiang, et al. "Large EEG Foundation Model Learns Informative Low-Frequency Representations from Intracranial Brain Signals." 1st ICLR Workshop on Time Series in the Age of Large Models. 2026.
[2]Merino, Eva Calvo, A. Faes, and M. M. Van Hulle. "The role of distinct ECoG frequency features in decoding finger movement." Journal of Neural Engineering 20.6 (2023): 066014.
[3]Kontras, Konstantinos, et al. "NeuroAtlas: Benchmarking Foundation Models for Clinical EEG and Brain-Computer Interfaces." arXiv preprint arXiv:2605.14698 (2026).
[4]Xiong, Wei, et al. "EEG-FM-Bench: A Comprehensive Benchmark for the Systematic Evaluation and Diagnostic Analyses of EEG Foundation Models." Forty-third International Conference on Machine Learning.
[5]Liu, Dingkun, et al. "EEG Foundation Models: Progresses, Benchmarking, and Open Problems." arXiv preprint arXiv:2601.17883 (2026).