- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper studies an interesting question: whether low-temporal-resolution fMRI can improve language encoding models for high-temporal-resolution ECoG. The authors fine-tune WavLM Base+ on fMRI responses to spoken narratives, freeze the tuned model, and use its speech representations to predict high-gamma ECoG responses with ridge regression. The fMRI-tuned WavLM outperforms the pretrained WavLM, especially in auditory cortex and the language network. Further analyses suggest that the gains are not limited to low-frequency signals, are robust to fMRI downsampling, and increase with more fMRI-tuning data.
Strengths and weaknesses
Strengths:
- The research question is practically important. ECoG data are hard to collect, while fMRI data are relatively easier to obtain. Using fMRI to improve ECoG encoding models is therefore a reasonable and useful direction.
- The cross-recording-method setting from fMRI to ECoG is interesting. fMRI and ECoG have very different temporal resolutions, but the authors show that fMRI-tuned representations can still improve ECoG prediction.
- The experimental pipeline is clear. The main structure is easy to follow: spoken audio is passed through WavLM, the model is tuned with fMRI responses, the tuned WavLM is frozen, and its representations are then used for ECoG ridge regression.
- The use of natural language stimuli is also a strength. The fMRI data use natural spoken stories, and the ECoG data use podcasts, making the task closer to real language understanding than experiments based only on isolated words or short sentences.
Weaknesses:
- The experiments mainly use one speech model, WavLM Base+, with a focus on layer 9. The paper mentions HuBERT, WavLM, and Whisper as useful models for speech-brain encoding, but the main evidence here is still centered on WavLM Base+. It is not clear whether the same conclusion would hold for other speech models or other layers.
- The baselines are still not sufficient. The main comparison is between fMRI-tuned WavLM and pretrained WavLM, but this does not rule out the possibility that ordinary speech-related fine-tuning, regularization, or extra speech exposure could lead to similar gains. Useful baselines would include stimulus-only tuning, BigSLM target tuning, phoneme tuning, or semantic tuning. These controls would help test whether the improvement really comes from the fMRI target.
- The ECoG temporal model is relatively simple. The authors use single-lag ridge regression because of computational cost, rather than a full FIR model. This choice is understandable, but it may not fully capture language responses at multiple time scales in ECoG. The paper could add an FIR analysis with reduced-dimensional features, or report how stable the results are across different lags. It would also help to clarify whether the best lag is selected strictly within cross-validation.
- The improvement in auditory cortex may mainly reflect acoustic features, not necessarily higher-level language representations. The authors could add acoustic, phoneme, and semantic probes, or test whether fMRI-tuned WavLM still adds predictive power after controlling for acoustic and phonetic features.
- The ECoG evaluation uses only one Podcast dataset. The paper would be stronger with more detailed per-patient results, an analysis of how electrode coverage affects the findings, or validation on another ECoG dataset.
- I also noticed a citation-numbering issue: the main text refers to the “Podcast” ECoG dataset as [30], but the reference list indicates that the Podcast ECoG dataset is [29], while [30] is Antonello et al. on scaling laws for fMRI encoding models.
Questions
- Do the results depend on WavLM layer 9? Would other WavLM layers, HuBERT, Whisper, or wav2vec 2.0 show similar fMRI-to-ECoG transfer effects?
- Is the improvement mainly acoustic, phonetic, or semantic? Does fMRI-tuned WavLM still help after controlling for speech envelope, spectrogram, or phoneme-level features?
- The downsampled-fMRI result is interpreted as evidence for temporal generalization. Should the downsampled-fMRI result be interpreted as slow-to-fast transfer, or as robustness to low-frequency or denoised fMRI supervision?
- In Section 2.4, the authors fit separate ridge models for 81 lags from -2 to +2 seconds and report the best-performing lag. It is not clear whether this lag selection is done within the cross-validation loop, or whether the best lag is chosen using the same scores later reported as final performance. Could the authors clarify this? It would also help to report the selected lags across electrodes and regions, and to show whether the main results hold when the lag is fixed or more tightly constrained.
- Minor note: In Section 3.4, should the citation to the “Podcast” ECoG dataset be [29] rather than [30]? Section 2.4 cites the Podcast dataset as [29], and the reference list shows that [29] is the Podcast ECoG dataset, while [30] is Antonello et al. on fMRI scaling laws.
Limitations
The main limitation is that the experiments do not fully isolate the role of correctly aligned fMRI responses. The paper shows that fMRI-tuned WavLM improves ECoG encoding over pretrained WavLM, but it does not include a temporally structured mismatch control. As a result, part of the gain could still come from general speech-related fine-tuning, regularization, or domain adaptation, rather than matched fMRI supervision. Another limitation is the statistical dependence among ECoG electrodes. The dataset has many electrodes but only 9 patients, and electrodes from the same patient are not independent samples. Electrode-level tests may overstate the evidence. Patient-level results, mixed-effects analysis, or patient-wise bootstrap would make the statistical support stronger. The source of the improvement is also not fully separated. Since the largest gains appear in auditory cortex, the effect may partly reflect better acoustic or phonetic encoding, not only higher-level language representation. It would help to show whether fMRI-tuned WavLM still explains extra ECoG variance after controlling for lower-level speech features.
Paper formatting concerns
None.
Final justification
I still have some concerns and would keep my original rating. The rebuttal strengthens the basic finding that fMRI tuning can improve ECoG prediction, but I am less convinced by the broader interpretation. In the paper, the authors suggest that fMRI tuning may produce “more brain-like representations” and conclude that the results provide “strong evidence that brain-like representations are highly modality invariant.” However, in the new controls, the LLaMA-tuned, word-rate-tuned, and articulation-tuned models all have numerically higher mean encoding scores than the fMRI-tuned model. This makes it unclear how much of the gain comes from brain-related information in fMRI, rather than from more general stimulus-related fine-tuning. The shuffled-fMRI control is useful and shows that alignment matters, but I do not think the new results fully resolve this concern. I therefore plan to keep my original rating.
We thank Reviewer ptyU for their time and helpful feedback. We respond point-by-point below:
We chose layer 9 of WavLM because it had the highest baseline fMRI performance in that model, and we do not claim that the choice of layer or model is critical for our results.
We are fine-tuning additional model to address concerns about these choices, and we will update this response once they are completed.
Previous work has shown that fMRI-tuning mainly improves semantic representations (Vattikonda et al. (2025); Moussa et al. (2024)). We are running controls against these low-level features and will update this response once completed.
We follow the evaluation procedure used in the original dataset (Zada et al. (2025)). The authors find the lag with the best test performance, and report that score as the performance of the electrode. Selecting the best model on the test set is not ideal, and will inflate performance values. However, we chose to retain this procedure both to match earlier work on this dataset and because our metric of interest is not the absolute performance but the difference between two models that are equally affected.
Thank you for catching this. We will fix this in the manuscript.