- Rating
- 5
- Clarity
- 3
- Confidence
- 5
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper considers the problem of estimating noise ceilings for brain scores, upper bounds on the performance that encoding models can achieve given noisy neural recordings. The authors propose a unified mathematical framework for trial-based brain recordings and use it to analyse several commonly used noise-ceiling estimators. Under this framework, they derive closed-form expressions or asymptotic characterisations showing how these estimators behave in within-subject and across-subject settings, and when they are expected to be biased. The authors validate their theoretical predictions using synthetic fMRI-like simulations, and compare the resulting estimator behaviour to real fMRI data (Sherlock dataset) across several brain regions. In addition, the paper proposes an AIC-based procedure for identifying signal-carrying recording units and concludes with practical recommendations for which estimators to use in different experimental regimes.
Strengths and weaknesses
This is a useful and timely paper that addresses an important methodological problem in NeuroAI and computational neuroscience: how to estimate noise ceilings for brain scores in a way that supports meaningful comparison across models, datasets, regions, and experimental settings.
The paper is generally clear and well motivated. The synthetic experiments support the theoretical analysis, and the "Sherlock" analysis helps to connect the framework with real fMRI data. I also appreciate the practical recommendations and the proposed AIC-based procedure for identifying signal-carrying units before computing noise-normalised scores.
To offer constructive criticism, my main reservations concern scope and practical usability.
-
Although the framework is presented as broadly applicable across recording modalities (the paper explicitly mentioning fMRI, EEG, and MEG), the empirical analyses are limited to fMRI. How do the assumptions and recommendations transfer to EEG and MEG (where temporal autocorrelation, sensor/source mixing, trial structure, and alignment issues may differ substantially)? Even a small non-fMRI demonstration (e.g. EEG-only) would go far to strengthen the paper's impact.
-
One of the most important conclusions is that no existing estimator is reliable in regions with large between-subject variability. This is a valuable diagnosis, but the paper could do more to give actionable guidance for precisely this difficult setting.
-
Probably the main estimators are specified clearly enough, but the AIC-based signal-unit selection procedure involves practical choices such as split-half sampling, fitting the trend, choosing the tolerance parameter, and handling finite-sample uncertainty. A reference implementation would help researchers apply the recommendations consistently.
Finally, a more minor suggestion: The real-data validation (Sherlock analyses) are useful, but mainly qualitative, with synthetic parameters chosen to mimic empirical behaviour rather than being quantitatively fit and tested. This could be strengthened.
Questions
-
The framework is presented as broadly applicable across recording modalities, with discussion of fMRI, EEG, and MEG. Could the authors clarify which assumptions are required for applying the estimators to EEG/MEG data, especially given differences in temporal autocorrelation, sensor/source mixing, trial structure, and alignment? A small non-fMRI demonstration, if feasible, would substantially increase the practical impact of the paper.
-
In regions with large between-subject variability, the paper concludes that no existing estimator provides a reliable estimate of the relevant noise ceiling. What should practitioners do in this setting? For example, should they report bounds rather than point estimates, include specific diagnostics, avoid normalised brain scores, or prioritise within-subject repetitions where possible? Clearer guidance here would make the paper more actionable.
-
Could the authors provide code or a more detailed implementation recipe for the estimators and the AIC-based signal-unit selection procedure? In particular, it would be helpful to specify practical choices such as the number of split-half samples, how to fit the trend, how to choose the tolerance parameter, and how to handle finite-sample uncertainty.
-
The real-data analysis on the Sherlock dataset is useful but mostly qualitative, with synthetic parameters chosen to mimic empirical behaviour. Could the authors strengthen this by quantitatively fitting the generative model to real data, or by reporting a more explicit goodness-of-fit / predictive check? This would clarify how well the proposed framework captures real recordings beyond qualitative agreement.
A stronger response on questions 1-3, especially clearer guidance for high between-subject variability regimes and practical implementation details, would increase my confidence in the paper’s impact and usability.
Limitations
The paper is generally careful about the limitations of existing noise-ceiling estimators, and the authors are clear that no existing estimator is reliable in regions with large between-subject variability.
That said, the limitations of the proposed framework itself could be discussed more explicitly. In particular, the paper could clarify the scope of its assumptions for non-fMRI modalities such as EEG and MEG; discuss the practical limitations of the AIC-based signal-unit selection procedure; and provide more actionable guidance for practitioners working in high between-subject-variability regimes.
As discussed above, I would also encourage the authors to discuss whether code will be released, since implementation details are important for consistent use of the proposed recommendations.
Paper formatting concerns
I did not notice any major formatting, anonymity, or submission-policy concerns.
Final justification
Thanks to chairs and to the other reviewers - it was helpful to read your reviews.
I updated the contribution type from "Theory" to "General" to match what the authors selected, though I think "Theory" would have been a better fit. I chose not to lower my score under the recategorisation, though it's possible my rating would have been lower had I not originally approached the work as a "Theory" paper.
I can see that my rating (5: Accept) is more positive than the other reviews (4: Borderline Accept). Some of the difference may be taste: the work in this paper touches on relevant and interesting problems to me.
In my comments to the authors, I noted that while they pitched the paper as being useful across neuroimaging modalities, it mainly focused on fMRI - to the exclusion of EEG/MEG. This mattered less to my rating when I approached the work as "Theory" rather than as "General". This is important, as a deficit in empirical results to support the claims might have led me to score the paper lower (e.g. 4). On the other hand, I'm happy enough with the authors' addition of the EEG analysis during rebuttals to keep my score at 5.
I was entirely satisfied by the inclusion of the AIC selection procedure - I previously viewed its omission as an oversight and not a serious flaw.
I very much appreciate the authors' attempts to answer the question about guidance for high across-subject variability. On the one hand, the paper is framed in a way that would place this question out of scope. On the other hand, it's harder to know how to put the results from this paper to use without a more comprehensive answer to it. So, while I think the paper is consistent without doing more, the paper's lack of a stronger answer to this question does affect my sense of the its potential impact.
Finally, in my review I promised the authors that I would increase the confidence of my rating if they addressed my comments. They did. So, as I started with a confidence of 4, I raised it to 5 in acknowledgement of their efforts.
Meta-review
Comments after Rebuttal: The authors provided a thorough rebuttal and all reviewers now view the paper as above bar for acceptance. I have raised my recommendation accordingly.
Comments before Rebuttal: This paper tackles an important and under-served subject and two of the three initial reviews view it as above the bar for acceptance. Before fully recommending acceptance I would like to see further discussion and ideally a consensus among the three reviewers. In particular, all of the reviewers noted that empirical validation was rather limited and it is expected that the proposed method would perform well in simulations that match its assumptions.
I would like to see a clear rebuttal responding to the weaknesses raised in the initial review, in particular: