- Rating
- 4
- Clarity
- 3
- Confidence
- 3
- Originality
- 2
- Quality
- 3
- Significance
- 2
Read review
Summary
This paper studies the problem of zero-shot visual decoding from EEG. Although EEG is cheap and offers high temporal resolution, its low signal-to-noise ratio, non-stationarity, and coarse spatial resolution make semantic-level visual decoding quite challenging. The authors show that existing EEG-visual alignment methods mostly rely on holistic EEG embeddings, overlooking the complementary temporal, spectral, and spatial structures within the signal. To address this, the authors propose a unified multi-view EEG representation learning framework that, without modifying the pre-trained visual encoder, focuses on learning a stronger EEG encoder. It models three views in parallel: temporal dynamics based on a selective state space model, adaptive spectral modeling via learnable wavelet decomposition, and attention-modulated graph-convolutional spatial modeling. After fusing the three, it aligns them to the visual semantic space through contrastive learning and two EEG-specific regularizers achieving 200-way zero-shot classification. On the THINGS-EEG dataset, the method outperforms existing approaches across three settings: within-subject, cross-subject, and cross-session. The authors also introduce the first systematic benchmark for cross-session EEG-image decoding. Ablation and representation analyses further show that the three views capture complementary, non-redundant information.
Strengths and weaknesses
Strengths:
- This paper addresses the gap that existing methods rely on holistic EEG embeddings, the authors propose modeling three complementary views (temporal, spectral, and spatial) separately and then fusing them, which is a well-motivated and clearly reasoned way. The authors use design choices specifically tailored to the characteristics of EEG signals: the use of learnable wavelet decomposition in place of fixed frequency bands for spectral modeling, and of an attention-modulated dynamic graph for spatial modeling.
- Solid empirical validation: the method outperforms existing approaches across all three settings (within-subject, cross-subject, and cross-session), and is supported by complete ablations of both the modules and the regularizers.
Weaknesses:
- Looking at Table 2 subject by subject, the method actually trails the baselines on several subjects (e.g., sub3 is below UMind and ATM-S, sub4 is below UMind), and the 15.3% average lead is largely driven by a subset of subjects. However, the paper emphasizes that the method has a higher median, lower variance, and greater stability, which doesn't align with the per-subject data very well. The claimed cross-subject SOTA holds mainly in an average sense rather than as a consistent lead.
- From my perspective, it seems that all experiments come from a single fixed random seed (from Section 4.3 and Appendix C). The results has no variance or confidence intervals reported across multiple runs. This design setting may need discussion given that EEG decoding is inherently high-variance, and that the paper positions lower variance and stronger robustness as one of its core selling points.
- The cross-session evaluation is compared against only a single baseline (UBP). Since this is a newly defined protocol introduced by the authors, several baselines should be compared under it.
- The module ablation (in Table 4) is conducted on only a single subject (sub10), which may be too sample to support the general conclusion that the temporal, spectral, and spatial modules are each indispensable. A better way is to average across multiple subjects.
Questions
The paper's core claim is that the combination of temporal/spectral/spatial outperforms holistic EEG embeddings. The current ablation only shows that removing a view drops performance, which demonstrates each view contributes but not that the multi-view decomposition itself yields gains beyond a single sufficiently strong backbone. So, could you add a control comparing your three-view framework against a parameter-matched single-branch encoder (e.g., directly encoding raw multi-channel EEG with S3M/Transformer alone) under the same alignment objective and regularizers? If the two perform comparably, the gains stem mainly from encoding capacity rather than the multi-view structure. If the three-view design is clearly better, it would directly support the paper's core claim.
Limitations
Yes
Paper formatting concerns
N/A
Final justification
I raised my rating from 3 to 4. The rebuttal is detial on the experimental side: a parameter-matched single-branch control, an all-subject ablation, five-seed runs, significance tests against all baselines, and in the final round two extra cross-session baselines adapted to the held-out-session protocol.
That said, my rating reflects the rebuttal more than the original framing. The claims have shrunk quite a lot along the way: SOTA is now scoped to peer-reviewed methods available at submission; the cross-subject claim went from higher median and lower variance to highest average, with the margin over ATM-S and UMind not significant; "first systematic" now carries three qualifiers; "non-redundant, complementary" became "less-aligned learned subspaces"; and complementarity is now only the claim that the full model is best on average, with the authors agreeing that not every two-view combination helps. Each revision is fair on its own, but three of the four contributions have been weakened, and what is left is a solid three-branch EEG encoder with good within-subject numbers and a useful but still thinly compared cross-session protocol. Also, one number worth flagging: under cross-session, the Top-1 margin over UBP is 1.12 points and not significant (p=0.1250). The two new baselines are much weaker and do not change that, though the Top-5 gain is large and significant.
I think accept now outweighs reject, but I would not object if the AC weighs the contribution level differently from the technical soundness.
Meta-review
The paper proposed a new EEG representation learning framework to align brain response with visual semantic embeddings. The reviewers agree that explicitly modeling temporal, spectral, and spatial EEG structure is reasonable, and they appreciate the inclusion of within-subject, cross-subject, and cross-session evaluations. However, several serious reservations currently preclude publication.
First, the state-of-the-art and novelty positioning appears incomplete. One reviewer identifies several contemporary methods that are absent from the comparison and reportedly achieve substantially higher THINGS-EEG accuracy. Even without consideration of missing references, the method is not stably outperform the baselines reported in this paper. Second, the experiments do not establish that the multiview decomposition is the source of the gain. The contribution from architecture, capacity, and loss contributions are confounded. This also undermines claims of lower variance and robust generalization, especially because cross-subject improvements are not consistent across subjects and cross-session evaluation includes only one baseline. Third, several interpretive claims exceed the evidence. Near-zero cross-view cosine/CKA after projection and normalization does not demonstrate distinct physical mechanisms. Alignment only to the final CLIP layer is difficult to reconcile with the paper's multi-scale visual motivation, and the RCR objective may suppress structured repetition/adaptation effects rather than only noise.
Before the rebuttal, I encouraged the authors to correct possible factual errors, improve the clarification, carefully check the potentially missing references and results, as well as fairly justify their contributions and revise possible overclaims. During the rebuttal, The authors resolved the most serious methodological concern by adding parameter-matched single-view controls and applying the same CPCA/RCR losses to a strong baseline, showing that the improvement is not explained by capacity or regularization alone. The authors also added multi-seed evaluation, all-subject ablations, statistical tests, and a broader cross-session comparison. Several related-work objections were shown to involve non-comparable modalities or contemporaneous work and should not be used as grounds for rejection. The authors appropriately narrowed the SOTA, cross-subject, cross-view, and neurobiological claims.
However, it doesn't eliminate all reasons for rejection. The reviewers and the authors had some discussion during the discussion period. The cross-session Top-1 improvement over the strongest baseline is limited and not statistically significant; low cross-view cosine/CKA supports only less-aligned learned subspaces, not physical independence or strong complementarity; and the fixed-wavelet control that would further separate learned spectral modeling from architectural decorrelation was not provided. But overall the reviewers are all lean towards acceptance.
The decision was tough. Yet the sound empirical contribution, the new attribution controls, and the useful cross-session protocol slightly outweigh the remaining concerns. So I would recommend an acceptance given the belief that the authors can revise the title, tune down there claims to prevent any overstates, and adding more references in the final version.