- Rating
- 3
- Clarity
- 2
- Confidence
- 4
- Originality
- 2
- Quality
- 3
- Significance
- 2
Read review
Summary
The authors introduce CAIA, a cognitive-guided framework for EEG/MEG-based visual decoding. The pipeline features EEG-driven cross-modal attention for fusing saliency-guided blurred images, combined with an information-bottleneck-inspired frequency band selection. Utilizing a novel distribution-aware boundary calibration loss, the method is evaluated on the THINGS-EEG and THINGS-MEG datasets, demonstrating its zero-shot image retrieval (200-way).
Strengths and weaknesses
Strengths:
- Combining visual-side information reduction with EEG-side signal screening is intuitive and relevant.
- The method reports strong improvements over several recent EEG visual decoding baselines.
- The ablation study separates the effects of adaptive blurring, frequency screening, and boundary calibration.
- The paper includes both EEG and MEG evaluations, which broadens the empirical scope. Weakness:
- The paper makes strong cognitive and neuroscience claims, but the evidence is mostly retrieval performance rather than direct validation of cognitive mechanisms. The paper lacks sufficient statistical evidence, such as confidence intervals, multiple seeds, and significance tests.
- The reported gains are very large, so the paper needs stronger evidence that they do not come from protocol differences or preprocessing advantages. The comparison with prior methods may not be fully fair unless all baselines share identical preprocessing, channel selection, visual encoders, and evaluation protocols.
- A substantial performance gap remains between the subject-dependent and subject-independent settings, highlighting limited cross-subject robustness. Inconsistent bolding in the performance tables raises concerns regarding the rigor and accuracy of the reported results.
- The evaluation relies on averaged repeated trials, which weakens the claimed relevance to practical real-time BCI.
- The interpretability claims are not fully convincing because the attention and frequency analyses are mostly post-hoc visualizations.
- The method is validated only on retrieval, so it is unclear whether it improves broader neural-visual decoding tasks such as reconstruction or semantic generation.
Questions
see weakness
Limitations
yes
Paper formatting concerns
no
Final justification
The rebuttal has improved my assessment of the paper. I am willing to reconsider its quality and originality and raise my score accordingly.
We thank the reviewer for the careful evaluation and for recognizing the relevance of combining visual-side information reduction with EEG-side signal screening, the strong improvements over recent baselines, the ablation study, and the EEG/MEG evaluation. We address the concerns on cognitive/neuroscientific claims, baseline fairness, statistical robustness, cross-subject generalization, repeated-trial averaging, interpretability, and retrieval-only evaluation below.
1. On Cognitive and Neuroscientific Claims
We agree that the current evidence is stronger for retrieval performance than for direct cognitive or neuroscientific validation. In the revision, we will calibrate the wording throughout the manuscript. Specifically, we will replace stronger claims such as direct validation of selective attention or beta-band mechanisms with more precise language: the attention module provides EEG-dependent computational evidence for adaptive fusion, and the learned frequency weights are consistent with prior visual-attention literature rather than causal evidence for beta oscillations.
We will also revise the abstract, method analysis, and conclusion to present CAIA primarily as an effective neural-visual retrieval framework inspired by cognitive priors, rather than as a direct neuroscience discovery.
2. On the Statistical Robustness of the Reported Results
To address the request for statistical evidence, we conducted multi-seed experiments (5 runs) and report the mean performance with standard errors and 95% confidence intervals. The Top-1 accuracy is 69.66% ± 1.03 (SE) with a 95% CI of [66.79, 72.53]; the Top-5 accuracy is 95.80% ± 0.26 (SE) with a 95% CI of [95.07, 96.53]. In addition, we performed paired t-tests comparing CAIA against UBP across the 10 subjects using seed-matched runs, which yielded t(9) = 7.13, p < 0.0001 for Top-1 and t(9) = 11.35, p < 0.0001 for Top-5. These results confirm that the observed improvements are statistically significant and consistent across both random seeds and subjects. We will include these analyses in the revised experiments section.
Table1: CAIA performance across 5 seeds.
Table2: UBP results for paired comparison.
Table3: Paired t-test results.
3. On Baseline Fairness and Protocol Consistency
We confirm that all compared methods are evaluated under exactly the same protocol. All baselines operate on the identical publicly released THINGS-EEG/MEG .pt files, with the same 250 Hz whitened preprocessing, 0–250 ms post-stimulus window, 17 posterior EEG channels, repeated-trial averaging (4/80), 200-way retrieval, and a unified OpenCLIP ResNet-50 visual encoder. For method-specific hyperparameters, we respected the original configurations where compatible and tuned CAIA under the same validation pipeline. This ensures that any differences in performance reflect architectural choices rather than preprocessing, encoder, or evaluation protocol variations. To further address the concern about the large gains, we note that scaling UBP's encoder capacity to match CAIA's parameter count still leaves it far below CAIA's performance (51.3% vs. 70.3% Top-1), reinforcing that the improvement is not attributable to protocol or implementation advantages. We will add a dedicated paragraph to the revised manuscript clarifying these protocol-sharing details.
4. On the Reporting Accuracy and Cross-Subject Generalization
We agree that the gap between subject-dependent and subject-independent decoding remains substantial. This reflects the strong inter-subject variability of EEG signals and should be treated as a limitation rather than a solved problem. Nevertheless, CAIA improves over UBP in the subject-independent EEG setting from 12.4%/33.4% to 16.4%/45.7%, and in the subject-independent MEG setting from 2.2%/10.4% to 7.5%/21.8%. We will revise the discussion to emphasize that CAIA improves cross-subject robustness relative to prior baselines, but does not eliminate the subject-generalization challenge.
5. On Attention and Frequency Interpretability
To strengthen the attention analysis beyond visualization, we performed an EEG-shuffling counterfactual in which only the CrossModalAttention module receives EEG from a randomly selected different sample. This reduces performance from 70.3%/96.1% to 64.5%/92.0%, and the spatial correlation between correctly paired and shuffled attention maps is only 0.0057. This suggests that the gain from attention depends on correct EEG-image pairing rather than a static saliency or center-bias prior.
For IBWave, we tested stability across seeds and subjects. The learned frequency weights are stable, with within-subject cross-seed variation <=0.005, and removing the entropy regularizer reduces performance from 70.3%/96.1% to 67.8%/94.2%. We will add these analyses while framing them as suggestive interpretability evidence, not direct mechanistic proof.
6. On Repeated-Trial Averaging and BCI Relevance
We agree that repeated-trial averaging limits direct applicability to single-trial real-time BCI. In the revision, we will qualify the BCI-related claims and explicitly state that the current evaluation follows the THINGS-EEG protocol using averaged repeated trials. We will present single-trial decoding and real-time deployment as future directions rather than demonstrated capabilities of the current study.
7. On Retrieval-Only Evaluation
We agree that the current experiments evaluate zero-shot retrieval rather than reconstruction or image generation. We will revise the manuscript to avoid implying that the method has already been validated across all neural-visual decoding tasks. The current contribution is a retrieval-focused framework for improving EEG/MEG-to-visual alignment, and extension to reconstruction or generation will be described as future work.
8. On Table Bolding
We also thank the reviewer for pointing out the non-standard table bolding. We will revise all tables to bold only the single best entry in each comparison.
Thank you again for your insightful and meticulous feedback.