- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 4
Read review
Summary
Motivated by the multi-scale dynamics of continuous glucose monitoring (CGM) in diabetes, the paper under the "General: Most submissions will fall into this type." submission category proposes and evaluates GlucoFM, a lightweight self-supervised foundation model for CGM representation learning.
Strengths and weaknesses
The paper works on a timely application of machine/deep learning in diabetes that holds potential for a large global impact due to the prevalence of diabetes and current gaps in CGM sensor technologies. However, its evaluation methodology is insufficient to harvest this potential, because relevant metrics such as those reflecting time in range and hypoglycemia prevention mentioned on p. 1 of the paper have not been included in the evaluation. The author's response clarifies this standing now, making a convincing case for their study where these clinical metrics are not directly applicable but other comparative evaluations to give evidence of the clinically meaningful methodological gains are and have been achieved. Also, the current IRB statement and other ethical considerations are now sufficiently addressed. Finally, a clear and convincing explanation of the novel methodological contributions of this paper beyond integrating and slightly adapting the existing deep learning methods such as Transformers has been made; authors are encourage to revise their paper based on their own addressing of the reviewer comments, possibly sharpened by them reflecting on what the reviewers were highlighting as the strengths of their study.
Questions
Addressed: What are the key research contributions of the paper to deep learning methods, their specific applications to CGM data modelling, and applications to other time series signals?
Addressed: How does the model perform with respect to clinical metrics?
Addressed: How did you address ethical considerations related to the use of data from human subjects for the purposes of this study?
Limitations
The authors have briefly addressed the limitations of their work and proposed some future work, but otherwise their discussion part of this paper is somewhat lacking. How are you guiding future work to extend the framework as a deep learning contribution, apply it more generally to other data signals, and translate it into clinical practice in diabetes monitoring/management? What actionable advice would you give to methodological researchers, applied scientists, CGM-device developers, and clinicians interested in extending, applying, and translating this study?
Paper formatting concerns
None
Final justification
See above
We thank the reviewer for recognizing the timeliness of our work, and its potential global impact in diabetes. We address each question below.
Deep-learning methodology: GlucoFM is not a generic application of Transformer/JEPA. GlucoFM couples a mask-aware dual-stream encoder for slow trends and transient residuals with two complementary objectives matched to this architecture: masked prediction after fusion and cross-conditioned next-patch prediction before fusion. Dual-stream modelling improves task-averaged PR-AUC/ROC-AUC/Macro-F1 from 55.29/63.68/58.29 to 58.81/66.73/59.87; removing temporal prediction or CGM-aware augmentation also degrades performance.
CGM utility: The frozen lightweight encoder is evaluated across 4 cohorts, 7 phenotypes, and 14 cohort–task settings, including cross-dataset transfer, multiday aggregation, and few-shot learning. New biomarker-regression and postprandial glucose-response experiments further evaluate continuous metabolic phenotyping and dynamic prediction. Its compact design may support future on-device analysis, reducing transmission of privacy-sensitive raw CGM data.
Relevance to other signals: GlucoFM is intentionally designed as a CGM-specific, use-inspired model. We do not claim general-purpose applicability, and cross-signal evaluation is outside the scope of this work.
Time in range (TIR) is clinically important for glycemic management, but it is not a label-based metric for our retrospective diabetes-classification tasks. We therefore add a matched-window GMI baseline. Treatment-induced TIR improvement and hypoglycemia prevention require prospective evaluation; we will narrow the p.1 wording and identify them as future endpoints.
Rebuttal Table 6. GMI-equivalent comparison (Macro-F1, %)
Both methods use identical subjects and windows. GlucoFM reports 10 repeated subject-level CV runs, whereas GMI-equivalent is deterministic. For Fused, same-day Dexcom/Libre embeddings are averaged before multiday aggregation, and the baseline uses the corresponding combined readings.
The checklist’s “N/A” reflected our interpretation that no new recruitment or intervention occurred; we agree this was ambiguous and will correct it in the final manuscript.
Approval and consent: Both phases of the Wear-CGM study were approved by an independent IRB. All participants provided written informed consent explicitly permitting the use of de-identified data for secondary research and algorithm development. The present retrospective analysis falls within this consented scope.
Data governance and minimization. Although Wear-CGM contains multimodal measurements, this work uses only de-identified CGM data. Participant-level records remain access-restricted and will not be redistributed. All other raw datasets used in this work are previously released, de-identified research datasets accessed under their dataset-specific terms. No direct identifiers were available, and no re-identification was attempted.
To preserve double-blind anonymity, we omit the IRB name, protocol identifiers, and institutional details during review. These details will be included in the final manuscript and can be provided confidentially to the Program or Ethics Chairs upon request.
We add three complementary evaluations to provide a more concrete translation roadmap while separating demonstrated research utility from unvalidated clinical deployment, all using frozen representations and subject-disjoint protocols.
Rebuttal Table 7. TyG-defined fatty-liver-risk linear probing (mean ± std, %)
Rebuttal Table 8. Three-hour PPGR trajectory MAE (mg/dL)
Cross-sensor mean is the unweighted mean of the two sensor-specific MAEs, not a fused-sensor result.
Rebuttal Table 9. K=1 biomarker regression MAE
Train-mean is a non-representation baseline that predicts each test subject using the target mean from the corresponding training fold.
In summary, GlucoFM combines a novel CGM-specific dual-stream architecture with, to our knowledge, one of the most comprehensive evaluations among existing CGM FMs, spanning classification, forecasting, and regression. Additional analyses demonstrate functional pre-fusion stream specialization (Kkgy, Rebuttal Table 1), while frozen GlucoFM outperforms fully fine-tuned Chronos-2-small and MOMENT-small on all 3 metrics across 7 evaluations (rPuz, Rebuttal Table 4).
We hope these clarifications and new results address the reviewer’s concerns and invite reconsideration of the rating.