acceptodds
Published as a conference paper at NeurIPS 2026

PG-LRF: Physiology-Guided Latent Rectified Flow for Electro-Hemodynamic PPG-to-ECG Generation

Xiaoda Wang, Minxiao Wang, Kaiqiao Han, Defu Cao, Ching Chang, Yidan Shi, Runze Yan, Xiao Luo, Yan Liu, Xiao Hu, Yizhou Sun, Wei Wang, Carl Yang

Abstract

Electrocardiography (ECG) is the clinical standard for cardiac assessment but requires dedicated hardware that does not scale to daily-life monitoring. Photoplethysmography (PPG) is ubiquitous in wearables but lacks ECG-specific diagnostic morphology and is corrupted by motion and sensor noise. PPG-to-ECG generation aims to bridge this gap by recovering electrical morphology and timing from peripheral pulse signals. However, existing methods largely rely on statistical alignment and data-driven generation. They fail to explicitly structure the latent space around physiology-aware electro-hemodynamic factors and lack constraints from forward physiological dynamics. To address these challenges, we propose PG-LRF, a physiology-guided latent rectified flow framework. PG-LRF introduces an electro-hemodynamic simulator that co-models ECG and PPG through shared cardiac phase dynamics. Guided by this simulator, a Physiology-Aware AutoEncoder learns a structured electro-hemodynamic latent space. Then we integrate this simulator guidance into a PPG-conditioned latent rectified flow, enforcing ECG-side morphology consistency and ECG-to-PPG forward hemodynamic consistency during generative transport. Experiments on the large-scale MC-MED dataset demonstrate that PG-LRF significantly improves PPG-to-ECG generation and downstream cardiovascular disease classification, proving its ability to generate ECGs that are both signal-faithful and physiologically plausible under the ECG-to-PPG hemodynamic pathway

Keywords:
Sydney

Reviews

Among:
Shape:
123456this paper, Bottom 17%
Figure 1. Mean review rating of the reviewed papers at NeurIPS 2026. This paper averages 4.00 over 3 reviews, above 17% of the others.
Reviewer_BLDHOpenReview ↗
Rating
5
Clarity
3
Confidence
5
Originality
3
Quality
3
Significance
3
Read review
Summary

The authors propose PG-LRF. PG-LRF generates ECG from PPG by combining a physiology-aware latent space with simulator-guided rectified flow. Its electro-hemodynamic simulator links ECG and delayed PPG through shared cardiac phase dynamics, encouraging generated ECGs to be physiologically plausible and clinically useful. The model also performs well compared with baselines in both generation and downstream classification.

Strengths and weaknesses

Strengths

  • Well written and easy to follow.
  • The figures are clear and visually appealing.
  • The experimental details were clear and seem to be reproducible.
  • Ablation study on their loss components were appreciated.

Weaknesses

  • Evaluated solely on one dataset. I think this is the biggest weakness. Showing generation/classification performance on one more dataset would be a huge strength to this paper.
  • It would be helpful to see failure cases for the generation qualitative results.
  • See questions.
Questions
  • During training of both stages, what were some instabilities the authors noticed?
  • What was the most common failure mode during inferencing?
  • The authors mention that z score normalization was applied to each segment. Have the authors tried min max normalization? It would be interesting to see this comparison as I found for rectified flow for ECGs, min max yielded consistently better results. However, it may be different in your setting so I am curious whether my experience and yours aligned.
  • Will the authors open source the model?
Limitations

yes

Paper formatting concerns

NA

Final justification

The authors adequately carried out my requested experiments and answered all of my questions. I have adjusted the score accordingly.

Reviewer_dFeYOpenReview ↗
Rating
4
Clarity
4
Confidence
4
Originality
3
Quality
3
Significance
3
Read review
Summary

This paper addresses the issue of generating an ECG signal from a PPG signal. The authors propose PG-LRF, which includes the electro-hemodynamic generation problem and physiological guidance to address data-driven generation and statistical alignment. The method was evaluated using the MC-MED (a large-scale, multimodal clinical monitoring dataset) in terms of waveform-level, morphology and interval fidelity, and was compared with four other generative methods. The authors claim that their approach consistently outperforms existing baselines, generating ECGs that are signal-faithful and preserve critical clinical intervals, thereby improving the classification of cardiovascular disease.

Strengths and weaknesses

S1. Clarity of Physiological Rationale: The asymmetric relationship between photoplethysmography (PPG) and electrocardiography (ECG) wherein PPG represents the "delayed hemodynamic response" of ECG is expressed within a unified mathematical framework known as a shared heartbeat phase oscillator, thereby providing a physiological basis for the design choices.

S2. Ensuring Practicality Through Training-Inference Asymmetry: The utilization of the simulator and the ECG-to-PPG forward mapper is exclusive to the training. Conversely, during the inference phase, the system functions solely on PPG input. This enhancement signifies a notable advancement in terms of its potential for integration into wearable devices and analogous applications.

S3. Multifaceted Evaluation and Large-Scale Data: This paper utilizes 118,385 clinical data points derived from real-world patient cases and employs a three-tiered evaluation framework. This evaluation includes the following metrics: waveform-level metrics (mean absolute error [MAE], root mean square error [RMSE], fractal dimension [FD], fractal integral dimension [FID]), clinically meaningful morphological metrics (PR interval, QRS width, QT interval, QTcF, ST-J60 deviation, P-wave/T-wave duration), and the area under the curve (AUROC) for multi-label heart disease classification. This comprehensive approach lends the results high persuasiveness.

S4. The validity of the ablation design is as follows: The two ablation scenarios, "Simulator Removal (w/o Sim)" and "PAE Removal (w/o PAE)," correspond to the two major design elements of this method. This methodological framework allows for experimental verification of the independent effects of each component.

W1. Unverified details regarding the training of the ECG-to-PPG forward mapper and its impact on performance: A paucity of verification regarding the training details and the impact on performance of the ECG-to-PPG forward mapper is observed. Despite the fact that G_p is frozen post-pre-training, the quality of said pre-training (i.e., the extent of waveform error) directly impacts the accuracy of the simulator-induced loss, as delineated in Equation (26). In the event that the mapper is found to be inaccurate, the regularization effect on ECG→PPG hemodynamic consistency may be weakened or distorted. However, it is important to note that the performance of the mapper is not evaluated in isolation.

W2. Limitations of generalizability due to evaluation using a single dataset: This paper is subject to limitations in terms of generalizability, which are attributable to the evaluation of a single dataset. As stated in Appendix E, the evaluation is constrained exclusively to MC-MED (Stanford-affiliated emergency department, 2020–2022). However, there is a paucity of evidence regarding the generalizability of these findings to different institutions, patient populations, or sensor devices. Further validation on public datasets, such as BIDMC, is necessary, along with a discussion of the applicability of these methods to data from other institutions.

W3. Insufficient verification of baseline implementation reproducibility and fairness: Adequate verification of baseline implementation reproducibility and fairness is lacking. All four baselines (CardioFlow, RDDM, CardioGAN, PPGFlowECG) have been adapted to the MC-MED setting, which differs from their original proposal settings (e.g., dataset, sampling rate). However, the absence of details regarding the adaptation process, such as the performance of hyperparameter tuning and the utilization of official implementations, hinders the ability to verify the accurate capture of baseline performance.

Questions

Q1. Robustness of ICD-stratified simulator fitting: How robust is the ICD-stratified simulator fitting when the number of samples in each ICD group is small, especially for rare disease categories? In such cases, the fitting procedure may become unstable. Do the authors have any fallback strategies, such as merging ICD groups or applying stronger regularization? It would also be helpful to include a sensitivity analysis showing how the results change when the number of ICD groups is varied.

Q2. Quality evaluation of the ECG-to-PPG forward mapper: Please provide a quantitative evaluation of the pretrained ECG-to-PPG forward mapper G_p, such as PPG waveform reconstruction error. In addition, have the authors investigated how the effect of L_sim in Eq. (26) changes when the mapper is intentionally weakened? Such an ablation study would help clarify the dependence of the proposed method on the quality of the forward mapper.

Q3. Generalization to other datasets: Do the authors have any preliminary results on datasets other than MC-MED, such as BIDMC or MIMIC-III waveform data? If not, how robust do the authors expect the trained model to be against differences in PPG sensor characteristics and sampling rates across datasets?

Q4. Inference efficiency and clinical practicality: Please provide the trade-off between generation quality and inference time when varying the number of ODE solver steps N. In addition, for potential real-time or online monitoring applications, what level of latency can be expected with the current architecture?

Limitations

Heart-rate dependence: The paper does not sufficiently discuss the robustness of PAT estimation under very high or very low heart-rate conditions. In such cases, adjacent beats may overlap, and ST-segment variations may affect the reliability of PAT estimation.

Diversity of sensor modalities: The impact of different PPG sensor modalities is not adequately considered. For example, reflected PPG and transmitted PPG, or smartwatch-type sensors and fingertip clip-type sensors, can exhibit substantially different waveform characteristics. It would be helpful for the authors to discuss how such differences may affect the proposed method and whether additional adaptation or calibration would be required.

Paper formatting concerns

There is a missing equation number (Eq.(??)) in the list of equations in Appendix B.2 (p. 15).

Final justification

The rebuttal addresses most of my concerns through additional cross-dataset evaluations, mapper analysis, sensitivity experiments, and inference-efficiency results. These additions substantially strengthen the paper.

One concern remains regarding baseline fairness, since PG-LRF was trained on MC-MED, while the baselines appear to use pretrained checkpoints without retraining on the same dataset.

Overall, the resolved concerns outweigh the remaining issue. I therefore raise my rating to 4 (Borderline Accept).

Reviewer_SNinOpenReview ↗
Rating
3
Clarity
3
Confidence
3
Originality
3
Quality
3
Significance
3
Read review
Summary

The paper proposes a physiology-guided latent rectified flow framework called PG-LRF. The proposed method overcomes the limitations of purely data-driven PPG-to-ECG generation. It uses a physiological simulator and a physiology-aware autoencoder to enforce electro hemodynamic consistency during training. Experiments on the MC-MED dataset show better results than baseline methods. It also outperforms downstream disease classification.

Strengths and weaknesses

Strengths:

  1. The paper introduces a novel method to integrate an electro hemodynamic simulator with latent rectified flow. This allows ECG signals to be generated based on physiological dynamics instead of relying on statistical/data-driven cross-modal translation.
  2. The method is evaluated on the MCMED dataset and outperforms other baseline methods.

Weakness:

  1. The evaluation is limited to only one dataset. Additional experiments on other publicly available dataset will give a more generalized result of the proposed framework. It will also give a clear idea whether the framework can beat all the baselines on different dataset. Other available dataset are : MIMIC-AFib [1] , VitalDB [2] , BIDMC [3].
  2. The effect of the number of sampling steps is not evaluated. There is no discussion about whether the same sampling steps are taken for all the baseline models or not. For example, PGFlowECG [4] achieves its best performance at T = 5.
  3. The paper also lacks a zero shot generalization experiment. For example, the model is trained on one dataset (let’s say MCMED) and evaluated on another dataset (MIMIC-AFib) without fine-tuning. This will give stronger proof of its robustness.
  4. There is also no discussion about how these values (λ_ecg = 5.0, λ_ppg = 0.25, λ_deriv = 3.0, and λ_peak = 12.0) are chosen.

[1] Noise detection in electrocardiogram signals for intensive care unit patients [2] VitalDB, a high-fidelity multi-parameter vital signs database in surgical patients [3] Toward a robust estimation of respiratory rate from pulse oximeters [4] PPGFlowECG: Latent Rectified Flow with Cross-Modal Encoding for PPG-Guided ECG Generation and Cardiovascular Disease Detection

Questions
  1. How does the model perform to generate correct ECG from noisy PPG as PPG quality varies substantially?

  2. Does the model outperform other baseline in visualization quality as well?

Limitations

yes

Paper formatting concerns

no

Final justification

I thank the authors for the detailed experiments. But my major concern regarding multiple dataset(W1) is not addressed. It has been merged with zero shot analysis (W3). W1 and W3 serve different purposes.

(W1) I asked for PG-LRF trained on each dataset with its own splits to see whether the proposed method wins as in Table 1 of the submitted paper. All reported external results use MC-MED trained checkpoints. So the comparison was not made.

(W3) There is also no analysis of how much performance is dropped under zero shot transfer.

I appreciate the clarifications on my other concerns. I therefore retain my original score.

Comments on the paper

1 comment
Meta-review

(a) Scientific Claims/Findings

The paper proposes PG-LRF, a physiology-guided latent rectified flow framework for generating ECG signals from PPG signals. The core claim is that existing data-driven generation methods fail to capture physiological constraints. To address this, the authors introduce an electro-hemodynamic simulator and a physiology-aware autoencoder that jointly model ECG and PPG through shared cardiac phase dynamics.

(b) Strengths

  • [SNin, dFeY, BLDH] Compelling motivation. The integration of an electro-hemodynamic simulator provides a principled, physiology-aware foundation that improves upon purely data-driven cross-modal translation.
  • [SNin, dFeY, BLDH] Comprehensive evaluation on MC-MED, demonstrating strong performance in both signal generation metrics and downstream cardiovascular disease classification.
  • [dFeY, BLDH] Well-designed ablation studies that clearly isolate and validate the independent contributions of the core architectural components.

(c) Weaknesses

  • [SNin, dFeY, BLDH] Limited evaluation datasets. Validating on a single dataset (MC-MED) restricts claims of generalizability. Evaluation or zero-shot testing on additional public datasets (e.g., MIMIC-AFib, BIDMC, VitalDB) is highly requested.
  • [SNin, dFeY, BLDH] Lack of clarity on implementation of chosen hyperparameters for given model, as well as baselines for fair comparison.
  • [SNin, BLDH] Additional qualitative examples and visualizations would be helpful, especially due to the reconstruction nature of the model.

(d) Recommendations

Please address the weaknesses above and from each reviewer during the rebuttal. In particular, the most critical weakness is the 1 dataset evaluation.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Related papers

Loading the map…

Discussion (0)

Sign in to comment.