S1. Clarity of Physiological Rationale:
The asymmetric relationship between photoplethysmography (PPG) and electrocardiography (ECG) wherein PPG represents the "delayed hemodynamic response" of ECG is expressed within a unified mathematical framework known as a shared heartbeat phase oscillator, thereby providing a physiological basis for the design choices.
S2. Ensuring Practicality Through Training-Inference Asymmetry:
The utilization of the simulator and the ECG-to-PPG forward mapper is exclusive to the training. Conversely, during the inference phase, the system functions solely on PPG input. This enhancement signifies a notable advancement in terms of its potential for integration into wearable devices and analogous applications.
S3. Multifaceted Evaluation and Large-Scale Data:
This paper utilizes 118,385 clinical data points derived from real-world patient cases and employs a three-tiered evaluation framework. This evaluation includes the following metrics: waveform-level metrics (mean absolute error [MAE], root mean square error [RMSE], fractal dimension [FD], fractal integral dimension [FID]), clinically meaningful morphological metrics (PR interval, QRS width, QT interval, QTcF, ST-J60 deviation, P-wave/T-wave duration), and the area under the curve (AUROC) for multi-label heart disease classification. This comprehensive approach lends the results high persuasiveness.
S4. The validity of the ablation design is as follows:
The two ablation scenarios, "Simulator Removal (w/o Sim)" and "PAE Removal (w/o PAE)," correspond to the two major design elements of this method. This methodological framework allows for experimental verification of the independent effects of each component.
W1. Unverified details regarding the training of the ECG-to-PPG forward mapper and its impact on performance:
A paucity of verification regarding the training details and the impact on performance of the ECG-to-PPG forward mapper is observed.
Despite the fact that G_p is frozen post-pre-training, the quality of said pre-training (i.e., the extent of waveform error) directly impacts the accuracy of the simulator-induced loss, as delineated in Equation (26). In the event that the mapper is found to be inaccurate, the regularization effect on ECG→PPG hemodynamic consistency may be weakened or distorted. However, it is important to note that the performance of the mapper is not evaluated in isolation.
W2. Limitations of generalizability due to evaluation using a single dataset:
This paper is subject to limitations in terms of generalizability, which are attributable to the evaluation of a single dataset.
As stated in Appendix E, the evaluation is constrained exclusively to MC-MED (Stanford-affiliated emergency department, 2020–2022). However, there is a paucity of evidence regarding the generalizability of these findings to different institutions, patient populations, or sensor devices. Further validation on public datasets, such as BIDMC, is necessary, along with a discussion of the applicability of these methods to data from other institutions.
W3. Insufficient verification of baseline implementation reproducibility and fairness:
Adequate verification of baseline implementation reproducibility and fairness is lacking.
All four baselines (CardioFlow, RDDM, CardioGAN, PPGFlowECG) have been adapted to the MC-MED setting, which differs from their original proposal settings (e.g., dataset, sampling rate). However, the absence of details regarding the adaptation process, such as the performance of hyperparameter tuning and the utilization of official implementations, hinders the ability to verify the accurate capture of baseline performance.
Meta-review
(a) Scientific Claims/Findings
The paper proposes PG-LRF, a physiology-guided latent rectified flow framework for generating ECG signals from PPG signals. The core claim is that existing data-driven generation methods fail to capture physiological constraints. To address this, the authors introduce an electro-hemodynamic simulator and a physiology-aware autoencoder that jointly model ECG and PPG through shared cardiac phase dynamics.
(b) Strengths
(c) Weaknesses
(d) Recommendations
Please address the weaknesses above and from each reviewer during the rebuttal. In particular, the most critical weakness is the 1 dataset evaluation.