This paper proposes a Mamba-2-based state-space model for heart rate estimation from facial video. Using a Linear Time-Invariant (LTI) state-space model equipped with temporal-spatial state-space attention duality (TSD), the authors have developed an rPPG model that balances accuracy and memory efficiency. Experiments using four datasets demonstrate that the model achieves state-of-the-art accuracy despite significant memory reduction.
Strengths and weaknesses
Strengths:
- By introducing SSM, the authors achieve streaming per-frame waveform inference, enabling real-time operation.
- Compared to well-known conventional rPPG networks, it significantly improves memory efficiency and minimizes latency.
- The authors ingeniously adapted the concept of state space duality for rPPG models.
- FacePhys achieves state-of-the-art performance despite a significant reduction in computational load.
Weaknesses:
- A major weakness of the experiment is that it is limited to heart rate estimation. While the introduction of SSM has been demonstrated to be effective for heart rate estimation, it remains unclear whether it is effective for HRV estimation, which requires more accurate peak estimation, or for blood pressure estimation, which requires estimation of detailed pulse waveform characteristics. In particular, since HRV estimation has also been performed in major previous papers (PhysNet, PhysFormer, Contrast-Phys), a comparison with these conventional methods is desirable.
- Doubts remain regarding the comparison with conventional methods in the experimental results. For example, in Table 3, it is stated that FacePhys achieves the lowest MAE of 5.58 for MMPD; however, the RhythmMamba paper reports that RhythmFormer achieved 3.07 and RhythmMamba achieved 3.16. Furthermore, while it is stated that FacePhys achieves the lowest MAE of 0.46 on UBFC-rPPG, Contrast-Phys+ achieves 0.21. An explanation is needed regarding the discrepancy with the performance reported in prior papers. Additionally, it is possible that performance comparisons with a sufficiently broad range of prior papers have not been conducted.
- Implementation details may be lacking. For example, is it mentioned what window size and sliding window are used to convert the estimated BVP signal into heart rate?
- It should explain the specific methodological differences and novelty of FacePhys compared to RhythmMamba, which already incorporates Mamba.
- There are no reports regarding differences in performance due to variations in skin tone. Since VitalVideo is used, it is expected that skin tone information is available.
Questions
- Is it possible to add the HRV estimation results to the predicted BVP signal? FacePhys is well-suited for capturing periodicity and long-term dependence through the introduction of SSM, contributing to improved heart rate estimation accuracy. Meanwhile, demonstrating that FacePhys contributes not only to heart rate estimation but also to HRV estimation would enhance the significance of this paper.
- Can you explain the difference between the MAE reported in previous papers and that in this paper?
- Please explain the implementation details and the methodological differences from RhythmMamba.
- Could you report on the differences in heart rate estimation performance due to variations in skin tone? Demonstrating that FacePhys contributes to improved robustness across different skin types would enhance the significance of this paper.
Limitations
- Could you please provide more details regarding the first limitation mentioned in this paper? It seems obvious that the model cannot access future information. Does this constitute a limitation compared to conventional methods (such as CNNs and Transformers)?
- The primary concern is that FacePhys may be limited to heart rate estimation. While FacePhys is effective at capturing periodicity and long-term dependencies—making it suitable for heart rate estimation—it may not be well-suited for HRV estimation or waveform reconstruction (for blood pressure prediction). If that is the case, these limitations should be added to the list.
Paper formatting concerns
N/A
Final justification
Since my concerns—such as the HRV results, the discrepancies in numerical values compared to previous studies, and the performance analysis across different skin tones—have been addressed, I’m raising my rating by one point.
e thank R3 for the detailed review and for recognizing that FacePhys ingeniously adapts state space duality to rPPG, enabling real-time per-frame streaming with strong efficiency. We have run new experiments for every point and will improve clarity as requested.
W1/Q1 · Beyond HR — HRV / waveform-level estimation
We agree HRV is the right test of waveform fidelity, and we ran it. From the predicted BVP on UBFC we detect beats → inter-beat intervals (IBI) → HRV indices vs. ground truth: mean-IBI MAE 8.45 ms (r = 0.98), SDNN MAE 16.4 ms (r = 0.83), RMSSD MAE 26.0 ms (r = 0.78).
The very high IBI correlation (0.98) confirms the complex oscillatory state yields beat-accurate waveforms, not just a correct dominant frequency. For a head-to-head against recent waveform-oriented methods, we scored PHASE-Net (CVPR 2026), PhysNet and PhysFormer against FacePhys with an identical pipeline, on the same 12 held-out UBFC subjects (PHASE-Net's own split: subjects 0–29 train, 30–41 test):
The baselines are competitive on HR (PhysFormer 1.74 ties PHASE-Net) but fall clearly behind on the beat-level HRV indices — exactly the regime FacePhys targets. We will temper further waveform-derived claims (e.g., blood pressure) as explicit future work.
W2/Q2 · Discrepancy with prior reported MMPD / UBFC numbers
We sincerely thank the reviewer for this careful observation. In response we re-examined both our evaluation protocol and our signal post-processing and re-ran the full comparison; we summarise the clarification below.
(a) The gap is primarily a protocol difference. Prior work on MMPD commonly reports a single fixed rPPG-Toolbox split that evaluates on roughly 20 % of the subjects. We instead adopt 5-fold subject-independent cross-validation covering 100 % of the subjects, and we re-train and re-evaluate every baseline under this identical protocol so that the comparison remains fair. The RhythmMamba paper itself states that on MMPD "the dataset was sequentially split into training, validation, and testing sets with a ratio of 7:1:2".
(b) We have corrected the post-processing band, following the reviewer's comment. While re-checking the pipeline we found that our original results applied a 0.5–3 Hz band-pass filter, whereas RhythmMamba adopts 0.75–2.5 Hz. A wider band admits more out-of-band noise, so our earlier setting was unintentionally unfavourable to those baselines. We therefore align the band-pass with each method's original implementation (0.75–2.5 Hz for RhythmMamba) and re-ran all comparisons; the table below gives the corrected intra-dataset MMPD numbers.
(c) How the two sets of numbers reconcile. Per-fold MAE ranges from 3.5 to 16.0 across methods and folds. Notably, RhythmMamba's best fold (3.54 on F0) is close to the 3.16 reported in its paper, which we think supports our reading: the published value corresponds to a comparatively easy subject subset. On the most difficult fold (F2) the same model degrades to 15.98, whereas FacePhys remains at 9.55; averaged over all subjects, FacePhys obtains 5.58 against 7.57. The two numbers are therefore not contradictory — they are simply measured on different subjects.
(d) UBFC-rPPG. We also traced the origin of the 0.21 figure. Contrast-Phys+ evaluates UBFC-rPPG under the fixed train/test split of Dual-GAN [Lu et al., 2021] — the first 30 subjects for training and the remaining 12 for testing — rather than cross-validation over the full set; RhythmMamba adopts the same split. Our 0.46 is instead averaged over all 42 subjects under 5-fold subject-independent CV, so the two are simply not measured on the same subjects. UBFC-rPPG is also close to saturation: recent methods report between 0.21 and 0.58 BPM, all an order of magnitude below the 3 BPM clinically acceptable margin, so we are reluctant to read a ranking into these differences. We further note that Contrast-Phys+ targets the unsupervised / weakly-supervised setting, which we regard as complementary rather than directly competing.
(e) Cross-dataset results. For the cross-dataset protocol there is no split to choose — the model is trained on one dataset and tested on the entire target set — so this is where a reproduction can be checked directly. On cross-dataset MMPD the best published results sit in the 9–10 BPM range (RhythmFormer 8.98 / 9.08, RhythmMamba 10.44 / 10.63, as reported in the RhythmMamba paper), and our re-trained baselines land in exactly the same band (RhythmMamba 9.62 trained on RLAP, 10.9 trained on PURE). We hope this reassures the reviewer that our pipeline reproduces the prior methods faithfully: the discrepancy raised in W2/Q2 appears only in the intra-dataset setting, i.e. precisely where the subject split differs.
Against that reference point, FacePhys reaches 5.30 BPM (trained on RLAP) and 8.45 BPM (trained on PURE) on MMPD, and is sub-1 BPM on VitalVideo (0.77), PURE (0.24) and UBFC-rPPG (0.48); it ranks first in all six cross-dataset settings of Tables 4 and 5, with relative gains of 13.5 %–61.9 %. The more telling comparison, we believe, is the stability across the domain shift: on MMPD FacePhys moves from 5.58 (intra, 5-fold, all subjects) to 5.30 (RLAP → MMPD), essentially unchanged, whereas RhythmMamba moves from 7.57 to 9.62 and the CNN baselines degrade considerably more. Since any real deployment operates cross-domain, this is the regime our claims rest on — and the regime where FacePhys's advantage is largest.
Summary of revisions. (i) all results re-run under the corrected band-pass setting and Table 3 updated; (ii) PhysMamba and PHASE-Net added to the comparison; (iii) the per-fold two-protocol table moved into the main text; (iv) a clarifying note that intra- and cross-dataset numbers must be compared within their own protocol; (v) exact fold splits and the full evaluation pipeline documented in the supplementary material, with split files and scripts released.
W3/Q3 · Implementation details (BVP → HR window / sliding window)
Thank you; we will add an Implementation Details subsection.
BVP → HR: (1) Butterworth band-pass [30–180 BPM]; (2) Welch PSD over a 160-frame (≈ 5.3 s at 30 fps) sliding window, stride = 1 frame in streaming mode; (3) peak frequency = HR. Our new window ablation reports HR-MAE at 1 / 2 / 3 / 5 / 10 / 15 / 30 s windows (7.67 / 3.90 / 2.78 / 1.83 / 1.35 / 1.21 / 1.01 BPM) so the accuracy–latency trade-off is explicit.
Training: Adam, MSE loss, 20 epochs, batch 32, FP16, DDP on 4×V100; augmentation ±30 % time-scaling for HR balancing, jitter, random frame erasure.
We also refer the reviewer to the supplementary material and the real-time in-browser demo.
W4/Q4 · Robustness across skin tones
We now report this on VitalVideo, the one benchmark that carries Fitzpatrick labels. HR-MAE: Fitzpatrick 1–2 = 0.54, 3–4 = 0.86, 5–6 = 3.82 (overall 0.85). We report the darker-skin degradation honestly — a known limitation of all camera-based rPPG (lower reflectance / SNR) — and add it to the broader-impact and limitations discussion rather than hiding it.
W5/Q3 · Methodological difference from RhythmMamba (novelty)
RhythmMamba uses Mamba as a temporal feature extractor inside a fixed-length chunk pipeline: it buffers N frames, processes them as a batch, and emits HR — O(TD) memory and an N-frame latency before any output.
FacePhys is true per-frame streaming: one frame in → one BVP sample out via a recurrent state update, O(D+L) constant memory independent of sequence length T, at 9.46 ms/frame in mobile browsers (supplementary demo) — which a chunk-based design cannot do.
Beyond streaming: our complex-diagonal state transition gives physiologically grounded periodic (oscillatory) dynamics as an inductive bias, and the temporal-spatial duality (TSD) decouples spatial (2D conv) from temporal (SSD) modeling. These are architectural contributions, not an incremental reuse of Mamba.
Limitations · No future frames; HRV / waveform scope
Streaming inference cannot use future frames, unlike offline CNN/Transformer batch inference — a deliberate cost of real-time, causal operation that only mildly affects HR (Table 6). We will state this clearly and list HRV/waveform (e.g., BP) as an explicit scope limitation, while noting the strong IBI correlation (0.98) already demonstrates HRV feasibility.
We hope the new HRV results, the matched PHASE-Net comparison, the two-protocol MMPD table, the implementation details, and the skin-tone analysis together resolve the clarity and significance concerns, and we kindly ask the reviewer to reconsider the rating.