- Rating
- 4
- Clarity
- 3
- Confidence
- 2
- Originality
- 2
- Quality
- 3
- Significance
- 3
Read review
Summary
The paper proposes ApexPhys, a continual learning framework for remote photoplethysmography (rPPG) under sequential domain shifts. The method combines three main components: Backbone Consistency Representation Preservation (BCRP), which estimates parameter importance using a Fisher-style measure derived from a physiological consistency loss and freezes high-importance backbone parameters; a Hierarchical Expansion Strategy (HES), which uses layer-wise VAE-based distribution descriptors and sliced Wasserstein distance to decide whether to expand or reuse adapters; and Prior-Guided Pathfinding (PGP), which initializes new adapters from the most similar prior domain and uses a curriculum plus path-stability constraint to stabilize adaptation. The paper evaluates the method on five public rPPG datasets under a domain-incremental protocol, compares against generic continual learning baselines and a prior continual rPPG method, and provides ablations, sensitivity studies, task-order tests, zero-shot evaluations, and parameter-growth analysis.
Strengths and weaknesses
The paper studies an important problem. rPPG models can fail when lighting, motion, camera type, or subject appearance changes. Continual learning is a reasonable setting for this problem. The main idea is clear: protect useful shared parameters, add domain-specific adapters when needed, and start new adapters from similar old ones.
The experiments are a strength. The paper compares with several continual learning baselines and with ADDP. It also reports ADDP with the same ViT backbone, which makes the comparison more fair. ApexPhys improves over ADDP(V) on MAE and RMSE. The ablations show that BCRP, HES, and PGP each help. The appendix also includes task-order tests, sensitivity studies, zero-shot tests, and parameter-growth analysis. Avoiding raw replay buffers is also a good choice because facial videos and physiological signals are sensitive data.
The main weakness is originality. The method builds on known ideas: Fisher-style parameter importance, adapters, routing, distance-based module selection, warm starts, and curriculum learning. The combination is useful for rPPG, but the algorithmic contribution seems incremental. The authors should state more clearly what is new beyond combining existing tools.
The setup also needs clearer discussion. The method seems to need labeled data for each new domain and clear domain boundaries. This may be hard in real deployment. Domain changes can be gradual, labels may not be available, and the system may not know when a new domain starts. The authors should clarify whether ApexPhys can work online and how much labeled PPG data is needed.
The BCRP explanation also needs more evidence. The paper says the Fisher score finds parameters that preserve physiological information. This is plausible, but not directly shown. The score may also capture sensitivity to augmentation or appearance. The results show that freezing helps, but they do not prove that the frozen parameters are truly physiology-related.
The evaluation is broad, but some gaps remain. The paper talks about physiological consistency and mentions HRV, but most metrics are for video-level heart-rate estimation. Waveform quality or HRV-related metrics would better support the claim. Table 6 also shows clear forgetting on VIPL domains. It would help to compare this per-domain forgetting with ADDP(V), SD-LoRA, and IDER. More random seeds or stronger statistical tests would also make the comparison more convincing.
The paper is mostly clear. The figures and tables are useful. Some details are still unclear: how the VAE descriptors are trained and stored, how routing works at test time, how the descriptor cost scales, and how baselines were tuned.
Questions
-
What deployment setting does ApexPhys assume? Does it need labeled PPG for every new domain? Does it need clear domain boundaries? Does it require offline training before use? A more realistic online or weakly labeled test would strengthen the paper.
-
Can the authors show that BCRP really finds physiology-preserving parameters? For example, frozen-vs-trainable layer analysis, waveform quality, frequency stability, or HRV metrics would help.
-
Table 6 shows notable forgetting on VIPL domains. Can the authors compare per-domain forgetting with ADDP(V), SD-LoRA, and IDER? This would show whether ApexPhys improves the hard cases, not only the average.
-
How were the baselines tuned, especially ADDP(V), SD-LoRA, and IDER? Please state the tuning budget, backbone, preprocessing, and compute for these methods.
-
Can the authors report waveform-level accuracy or HRV-related metrics? This would better test the claim about preserving physiological information.
Limitations
The limitations section is too short. It should discuss the need for labeled data, the need for clear domain boundaries, gradual or mixed domain shifts, fairness across skin tones and devices, and the focus on HR instead of broader signal quality.
Paper formatting concerns
No notable issues.
Final justification
The authors provided a thorough rebuttal and substantial additional experiments. The matched per-stage forgetting analysis, HRV and subgroup evaluations, efficiency profiling, and label-efficiency study strengthen the empirical evaluation and address several of my original concerns. In particular, the semi-supervised results indicate that ApexPhys remains effective with 50% labeled samples. However, performance deteriorates substantially at 25% supervision and below, while the fully unsupervised setting does not converge.
My main concerns therefore remain only partially addressed. First, the evaluated protocol still operates on pre-segmented domain batches and performs offline, multi-epoch adaptation. EDP may remove the need to provide an explicit domain identity, but no task-free, mixed or gradual stream, or online boundary-detection experiment demonstrates that the adaptation process itself is boundary-free. Second, the novelty response explains a coherent integration of BCRP, HES, and PGP, but does not establish a non-trivial interaction beyond known Fisher-style preservation, dynamic adapters, warm starts, and curriculum learning. Finally, the random-freezing and fixed-Fisher controls support the usefulness of BCRP, while the mask-overlap analysis supports its stability. Nevertheless, these results do not establish that the selected parameters are specifically physiological rather than generally task- or augmentation-relevant, and the full-model HRV results do not isolate BCRP.
Overall, the empirical case is stronger and the paper remains technically solid, but the central deployment, originality, and mechanism concerns are not fully resolved. I therefore maintain my rating of 4.
We sincerely thank the reviewer for the detailed and constructive feedback. In response, we clarify the integrated novelty and practical assumptions of ApexPhys and provide additional analyses and experiments to strengthen its methodological and empirical support.
Q1. The main weakness is originality. What is new beyond combining existing tools?
A1. ApexPhys derives its novelty from a unified preservation–expansion–optimization process rather than a simple combination of existing techniques. The details are below.
First, at the preservation level, BCRP determines what to preserve. It accumulates Fisher information across domains to identify and freeze parameters that remain consistently important under environmental variations, thereby preserving physiological invariance.
Second, at the expansion level, HES determines when and where to expand. It measures layer-wise distribution shifts and selectively reuses existing adapters or introduces new ones only where historical capacity is insufficient, enabling domain plasticity with sublinear parameter growth.
Third, at the optimization level, PGP determines how to optimize the expanded capacity. It initializes new adapters from the most similar historical domain and progressively relaxes the inherited constraints, enabling stable knowledge transfer.
Therefore, the novelty of ApexPhys lies in explicitly coupling what to preserve, when and where to expand, and how to optimize, forming a coherent continual adaptation process for balancing physiological invariance and domain plasticity.
Q2. Discussion about ApexPhys’s assumptions regarding labeled PPG data, domain boundaries, offline training, and online deployment.
A2. We claim Apexphys does not require explicit domain boundaries or domain identities as model inputs. Different datasets are used only to simulate environmental distribution shifts. For newly observed data, paired video–PPG samples are used for offline adaptation without retaining historical raw data and explicit domain identities. More importantly, it continuously learns from newly observed data while preserving previously acquired knowledge, rather than simply optimizing for the current environment. This enables the model to adapt to emerging distributions without replaying historical samples while maintaining its performance on previously encountered environments. The experimental setting is consistent with the supervised rPPG domain-incremental protocol introduced by ADDP.
Q3. Does BCRP truly preserve shared physiological information rather than domain-specific noise?
A3. We analyzed BCRP’s freezing-mask overlap across all six domains, with the top 60% Fisher-important backbone parameters frozen in each domain. Overall, 38% of all backbone parameters remain frozen throughout the sequence, equivalent to 63% of those frozen initially. Despite substantial environmental changes, this overlap indicates that BCRP repeatedly identifies a stable parameter subset rather than domain-specific parameters. Moreover, our ablation shows that the gain comes from selectively freezing Fisher-important parameters, rather than freezing itself, supporting BCRP’s preservation of cross-domain physiological representations.
Q4. Can the authors compare per-domain forgetting with ADDP(V), SD-LoRA, and IDER?
A4. We track forgetting on the initial VIPL1–4 domain by reevaluating its MAE after every training stage in the sequence VIPL1–4 → VIPL5 → BUAA → PURE → UBFC → MMPD. We repeat the complete sequence with three random seeds and report the mean ± standard deviation across runs. Across all stages, ApexPhys achieves the lowest VIPL1–4 MAE, demonstrating less forgetting than the compared methods.
Q5. How were the baselines tuned, especially ADDP(V), SD-LoRA, and IDER? Please state the tuning budget, backbone, preprocessing, and compute for these methods.
A5. We extend Table 14 to additional continual-learning methods under the same protocol. All methods use the same 12.49 MB ViT backbone and identical video preprocessing. ADDP(V) enables style and noise augmentation with 8 clusters, SD-LoRA uses rank r=4, and IDER maintains a replay buffer of 100 video samples. The domain-wise columns report cumulative additional storage beyond the shared backbone. For ApexPhys, each tuple denotes the cumulative number of adapters retained at the last three ViT layers.
The values represent cumulative additional model-parameter storage beyond the shared 12.49 MB backbone.
ApexPhys achieves the best MAE with storage-efficient, sublinear parameter growth by expanding adapters only when necessary. Although IDER adds no model parameters, replay-sample storage introduces additional storage and privacy concerns.
We further profile all methods under the same hardware and implementation settings. Inference and training times are normalized per frame, while FLOPs are measured on one input clip of shape (1,3,160,128,128).
ApexPhys achieves the best MAE with modest computational overhead, demonstrating a favorable trade-off among accuracy, storage, and computational efficiency.
Q6. How are the VAE descriptors trained and stored, and how does routing operate during inference?
A6. Each adaptable layer has an independent VAE trained on reshaped backbone features with reconstruction and KL losses. On the first domain, the VAEs are always trained, thereafter, a new VAE is trained only when HES expands an adapter. The VAEs and L2-normalized latent means μ are retained for SWD-based expansion and parent selection, without storing raw features.
At inference, input-dependent similarities with learned routing vectors produce softmax weights to dynamically combine adapter outputs (Eqs. 8–9).
Q7. Can the authors report waveform-level accuracy or HRV-related metrics?
A7. To assess our performance beyond HR, we further evaluate HRV on UBFC. We report LF, HF, and LF/HF using error STD, RMSE, and Pearson correlation (R), with LF and HF expressed in normalized units (n.u.).
HRV Estimation Compared with Conventional rPPG Methods
We further compare ApexPhys with continual-learning methods using the same backbone and training protocol, reporting the mean metrics across six domains.
HRV Estimation Compared with Continual-Learning Methods
ApexPhys achieves the strongest overall performance among continual-learning methods, showing that it preserves physiologically meaningful waveform variations beyond video-level HR. As images cannot be included in the rebuttal, we will add waveform comparisons to the revised manuscript.
Q8. How does ApexPhys perform across different skin tones?
A8. We evaluate the MMPD skin-tone and motion subgroups after continual learning across six domains and report the mean MAE results over three task orders. ApexPhys achieves the strongest overall performance on both subgroup evaluations, demonstrating consistent robustness to skin-tone and motion variations.
MMPD Skin-tone Subgroups
MMPD Motion Subgroups
Q9. The limitations section is too short.
A9. Although HES achieves more storage-efficient, sublinear growth by reusing adapters, novel distributions may still require new adapters and VAE descriptors, increasing storage and routing overhead in longer domain streams. Future work will explore adapter merging and pruning to reduce redundant modules and improve long-term scalability. We will discuss this limitation and potential improvements in the revised manuscript.