The paper studies four-class sleep staging (Wake / Light / Deep / REM) from near-infrared (NIR) video alone, under labels defined by polysomnography (PSG). Unlike prior NIR-video work, proxy-first methods that first reconstruct respiratory/cardiac waveforms, or methods that lean on EEG supervision via teacher distillation or cross-modal retrieval, the proposed framework, ViNUSS, stages directly from a learned video representation with no proxy reconstruction and no EEG-derived supervision. It comprises three parts: a Pixel-Wise Temporal Encoder (PTE) that applies short temporal convolutions per spatial location before spatial mixing; an Intra-Subject Discriminability Loss (ISDL) that contrasts stages within a single overnight recording to suppress subject-dominant variation; and a two-scale Sleep Dynamics Module (SDM) that summarizes within-epoch motion (ShortMamba) and models the full-night trajectory (bidirectional LongMamba). Evaluation is on KVSS (475 overnight recordings, ~3,250 hours, far-field, occluded, face-anonymized), where ViNUSS reaches 0.80 accuracy / 0.78 macro-F1.
Strengths and weaknesses
Strengths:
-
Real, well-matched use case. Contactless scalable sleep monitoring is a genuine clinical need, and KVSS is a realistic, punishing deployment setting. The design choices are tied to documented properties of this data: PTE is motivated by sleep-relevant motion being weak and spatially localized and getting diluted under spatial downsampling; ISDL is motivated directly by the t-SNE analysis (Fig. 2b) showing epoch embeddings cluster by subject rather than stage; SDM reflects the sequential structure of clinical scoring.
-
Strong motivation/diagnostic analysis and sensible proxy-free framing. Figures 1–2 show why video-extracted respiration deviates from contact belts under occlusion/movement, and why a naive 3D CNN attends to static high-contrast structures instead of thoraco-abdominal motion. The proxy-free formulation, plus the within-subject sampling semantics of ISDL, is a well-motivated combination that removes a real failure mode of prior pipelines (rPPG/respiratory extraction breaking under face anonymization and bedding occlusion).
Weakness:
-
The central claim is not validated. The paper's central claim is that learning directly from video is preferable to extracting physiological proxies. The supporting comparison (Table 1) beats a re-implemented SleepVST given oracle contact-sensor breathing/cardiac waveforms plus an optical-flow motion feature (0.78 vs 0.73 MF1). But the paper never validates whether the video itself provide informative sleep-stage evidence. A clean, low-cost experiment would be feeding reconstructed (or oracle) proxies as additional inputs together with video and show that performance does not improve.
-
No variance, single split, single site. All evaluation is one split at one hospital, with no variance reported and no cross-site transfer evaluated. The scale of the dataset (475 subjects) is relatively small.
Questions
-
Can you report an ablation feeding reconstructed and/or oracle physiological proxies (BW/CW) as additional inputs to ViNUSS. If the sleep staging performance does not improve, this would directly support the claim that NIR video already encodes the physiological evidence.
-
Can you provide any variance estimate or significance tests?
-
Is any cross-site or cross-dataset evaluation possible, given the modality-level claim depends on generaliation beyond one hospital?
-
How does ViNUSS compare to a simple clinical/wearable baseline a practitioner would realistically weigh against a camera system?
Limitations
yes
Paper formatting concerns
None
Final justification
The author's rebuttal addressed my primary concerns.
We thank the reviewer for a careful and constructive review. We address the weaknesses and each question below, with new results where these are complete and the setup where experiments are still running.
[W1 / Q1] Central claim not validated, and request for a proxy-fusion ablation
To test whether the video itself provides informative sleep-stage evidence, we designed two experiments, reported in (1) and (2) below.
(1) Staging from directly measured thoracic and abdominal effort.
The video carries respiration-related motion around the thoraco-abdominal region (Fig. 1a), and SVECAM indicates ViNUSS attends to it (Fig. 6a). Effort belts measure the corresponding motion directly, without attenuation from camera distance, viewing angle, or bedding. This asks whether the physiological evidence in video is comparable to what direct measurement provides.
We train two recent multivariate time-series models on KVSS and pass their epoch representations to the same SDM used in ViNUSS. The split, labels, and evaluation protocol are identical across rows.
Table R1. Four-class staging from ground-truth breathing waveforms (BW*). Unlike Table 1, both thoracic and abdominal channels are supplied.
Video-only ViNUSS is at least as strong on every metric. This parity does not imply the two carry identical information. SVECAM also shows that when larger body movements occur, ViNUSS can attend to them as well as to respiration-related motion (Fig. 6b), which belt waveforms do not represent. Experiment (1) therefore addresses the concern raised. NIR video provides informative sleep-stage evidence in its own right, rather than serving only as a degraded route to respiratory motion.
(2) Requested proxy-fusion experiment.
We are running this now. A waveform encoder following SleepVST produces an epoch-level representation, which is concatenated with the ViNUSS video representation. The combined embedding then feeds the epoch classifier and SDM exactly as the video representation does in ViNUSS, so the pipeline is unchanged apart from the added waveform features, and reported numbers will be measured after SDM. The waveform encoder is additionally fine-tuned on KVSS. Because faces are anonymized, rPPG-based cardiac recovery is unavailable, so cardiac waveform (CW) comes from the contact sensor in all conditions, and the breathing waveform is evaluated both reconstructed from video (BW) and as a contact-sensor oracle (BW*).
We will report the numbers as soon as they are available.
Our claim is that face-anonymized NIR video is independently informative for PSG-defined sleep staging and reaches strong performance without reconstructing waveforms at inference; consistent with this, the abstract and conclusion describe it as an "independently informative and complementary modality", and §5 flags integration with physiological signals as future work. We will make this intent clearer in the paper.
[W2 / Q2] No variance reported on a single split
We report subject-level nonparametric bootstrap confidence intervals (CIs), a common way to estimate variance when only a single held-out cohort is available [3]. The 70 test subjects are resampled with replacement over 5,000 iterations. Subjects rather than epochs are the resampling unit, since epochs within one night are strongly correlated and cluster-level resampling is appropriate under this dependence [4]. This estimates how much results would move had the test cohort been a different draw of patients, the uncertainty most relevant to a modality-level claim.
Table R2. Four-class performance with 95% CIs, applied identically to ViNUSS and baselines.
Intervals are narrow, roughly 0.04 wide for accuracy and MF1.
This also speaks to significance. The MF1 intervals for ViNUSS and the full-oracle SleepVST variant in Table 1 do not overlap, a conservative indication that the margin is not explained by sampling variation. The signal models from [W1 / Q1] overlap substantially with ViNUSS, consistent with the parity described there.
Per-stage intervals are widest for Deep (F1 0.674 [0.622, 0.720]) and tightest for Light (0.834 [0.814, 0.853]), following from Deep being the sparsest stage.
On the single split, the 335/70/70 division follows the KVSS dataset paper [5], keeping our numbers comparable to other work on the same cohort. We will state this explicitly in the camera-ready, since the wording in Appendix A.1 may read as if we designed it ourselves.
[W2 / Q3] Single-site evaluation with no cross-site transfer
On scale, prior video-based staging used single cohorts of at most 50 subjects (Table 1). At 475 subjects Hospital A is roughly an order of magnitude larger, though single-site evaluation remains a real limitation regardless of cohort size.
Cross-site evaluation is possible and we are running it. KVSS contains two further sites never used in training.
Table R3. Acquisition setup at the three KVSS sites. Sample frames from B and C will be added to Appendix A.
These were not recorded under a shared protocol. Viewing angle and distance change the apparent scale and direction of the same thoraco-abdominal displacement, and bed orientation changes where in the frame it appears. They also draw on different referring departments, so the patient populations differ as well. Each site was scored by its own technicians, so some label variability across sites is possible [6].
For adaptation we follow the Hospital C split defined in the dataset paper [5] and use a matched design at B, so both sites receive comparable amounts of site-specific data. Adaptation subjects are disjoint from evaluation subjects, and zero-shot results use the same evaluation subjects so the settings compare directly.
We evaluate two settings. The first adapts SDM only, recalibrating full-night structure to the new site without touching the extractor. The second additionally fine-tunes the representation module so the extractor adapts to the new camera geometry.
We will report zero-shot and both settings with bootstrap CIs during this period. Zero-shot shows whether the model transfers as it stands, and the adaptation settings separate how much of any gap is calibration to the acquisition setup from what does not transfer at all. §5 notes that broader validation across clinical sites remains important, and these experiments are a first step in that direction.
[Q4] Comparison against a clinical or wearable baseline
ViNUSS targets the longitudinal home monitoring setting motivated in §1, so the realistic alternatives are wearable, nearable, and contactless sensors rather than in-lab PSG. Wrist-worn devices and headband EEG are more mature and the practical choice for a single night in a cooperative adult, but require contact, charging, and sustained compliance, and prolonged wear can itself disturb sleep. Under-mattress sensors remove contact but are tied to one user and location, and acoustic and radar sensing is fully contactless yet sensitive to subject-sensor distance and non-respiratory motion, with limited spatial discrimination when more than one person shares the room (all discussed in §2.1). Video imposes no compliance burden once installed, retains spatial context for where the evidence comes from, and captures behavioral signals such as position changes and arousals.
A numerical comparison is limited by what KVSS contains. There is no concurrent actigraphy, PPG, or headband EEG, so any wearable comparison would cross datasets with different protocols and label distributions. It would also cross populations, since KVSS consists of patients referred for polysomnography, and staging in clinical populations is recognized as a distinct problem [7].
One home-grade contact sensor can be compared directly. Effort belts are used in home sleep apnea testing, and Table R1 stages from those signals on the same subjects, labels, and protocol. Video-only ViNUSS is at least as strong on every metric, without any contact sensor. We do not position this as replacing wearable staging, and §5 notes integration with wearable modalities as future work.
References
[1] Luo & Wang. ModernTCN. ICLR 2024.
[2] Jung & Kim. MambaSL. ICLR 2026.
[3] Efron & Tibshirani. An Introduction to the Bootstrap. Chapman and Hall/CRC, 1994.
[4] Field & Welsh. Bootstrapping clustered data. JRSS-B 69(3), 2007.
[5] Choi et al. Non-contact on-device detection of obstructive sleep apnea from infrared video. Nature Communications, 2026.
[6] Younes et al. Staging sleep in polysomnograms: analysis of inter-scorer variability. JCSM 12(6), 2016.
[7] Fonseca et al. A computationally efficient algorithm for wearable sleep staging in clinical populations. Scientific Reports 13, 2023.