- Rating
- 4
- Clarity
- 2
- Confidence
- 3
- Originality
- 4
- Quality
- 3
- Significance
- 3
Read review
Summary
You propose VCR, a two-stage self-supervised framework for incomplete wearable multimodal physiological signals. It designs an orthogonal tokenizer to geometrically decompose sensor embeddings into shared cross-modal semantics and modality-specific residuals, paired with a missingness-aware MoE backbone to adapt computation under arbitrary sensor dropout. The model introduces dual reconstruction losses for full and partial modality missing, and is validated on four real wearable health datasets covering classification and regression tasks. Results show consistent performance gains over supervised and self-supervised baselines on single/multiple modality missing scenarios, with HSIC metrics verifying effective feature disentanglement.
Strengths and weaknesses
Pros: 1. The geometric disentanglement design with clear theoretical grounding is very interesting. Different from prior multimodal methods that rely on soft orthogonal loss penalties, you try to construct strict orthogonal subspaces via QR decomposition and geometric projection operators to separate shared and modality-unique features. Mathematically, whitening combined with symmetric and idempotent projection guarantees statistical independence between two feature groups, fundamentally solving the information leakage issue of soft constraint disentanglement approaches like FOCAL.
-
VCR designs targeted structural masking loss, while existing wearable self-supervised models mostly only support full training-full test settings or single modality masking. It distinguishes between single missing modality (only reconstruct shared components) and simultaneous multiple missing modalities (abandon reconstruction entirely), avoiding hallucination of unobservable modality-specific physiological features. This is a practical design in real-world scenarios.
-
You test the model performance across diverse downstream tasks including emotion recognition, sleep staging, human activity classification and VO₂ regression, and covers single, double, triple modality missing combinations. You also provide comprehensive ablations for core hyperparameters, MoE position, subspace rank and feature composition, offering abundant empirical evidence to support design choices.
Cons: 1. You fail to formally define the negative sample set used in cross-modal alignment loss Eq. 4, leaving readers unable to confirm the sampling scope of negative wearable signal tokens. More critically, the loss formula contains logically conflicting optimization tendencies: the first term minimizes the similarity between anchor and all samples in set (including positive synchronized tokens ), while the second term maximizes the similarity between and positive samples . Without detailed weight control, the two opposing gradient directions will counteract each other during training, destabilizing cross-modal matching convergence. You must supplement the precise definition of and elaborate how the two competing loss terms are balanced to avoid mutual offsetting in optimization.
-
You suppose that shared components of one missing modality can be reliably inferred from remaining sensors when only one modality drops out, hence enabling shared feature reconstruction. However, you may ignore that if two highly correlated modalities (e.g., EDA and TEMP) are both lost, even the shared physiological semantics related to stress cannot be fully recovered from ACC/PPG alone. The structural masking loss lacks adaptive judgment for correlation strength between modalities, leading to forced reconstruction of unidentifiable shared features and introducing implicit hallucination risks.
-
When the MoE learns incomplete missing-modality inputs, the frozen tokenizer cannot adapt its whitening and projection rules to partial observation distributions, leading to distribution shift between pre-training and downstream missing scenarios. There is no joint fine-tuning ablation to verify whether freezing the tokenizer hurts representation robustness under sensor dropout.
-
You claim whitening with orthogonal projection guarantees and statistical independence of shared s / specific p, but I think it exists a potential error. For non-Gaussian latent distributions, zero covariance cannot equal statistical independence. You only proves linear decorrelation and incorrectly equates it to full feature disentanglement, overstating the theoretical guarantee of the orthogonal tokenizer.
-
You set a high initial rank to reserve large capacity for shared features, but the ablation shows that overly large pushes most physiological information into modality-specific residuals p, degrading the discriminative power of shared embeddings. You do not design an adaptive rank adjustment mechanism to balance shared and specific capacity dynamically. I think relying only on fixed hyperparameters may create a sensitive hyperparameter bottleneck that harms generalization across different wearable datasets.
Questions
See Pros and Cons.
Limitations
Limitations have been included in the paper.
Paper formatting concerns
No such concern.
Final justification
As stated in my final comment, I would retain my positive score, and I will be happy to see this work accepted on the condition that the authors polish the main figure (Fig. 2) and revise the serious theoretical issues.
Meta-review
(a) Scientific Claims/Findings
The paper proposes VCR, a self-supervised framework designed to learn representations from multimodal wearable physiological signals that are robust to sensor/modality missingness. The core claim is that current missing-modality approaches that attempt to reconstruct entire absent signals are prone to hallucinating modality-specific details that cannot be logically inferred from the available sensors. To address this, VCR uses an orthogonal tokenizer to geometrically decompose features into modality-shared semantics and modality-specific residuals, paired with a missingness-aware MoE backbone. The training objective is restricted to reconstructing only the shared components of missing modalities, thereby avoiding the hallucination of unobservable specific details.
(b) Strengths
(c) Weaknesses
(d) Recommendations